LAXCO, Inc. | 22121 17th Ave SE | Suite 114 | Bothell, WA 98021 | Tel: 1 425-381-9673 | info@laxcoinc.com | www.laxcoinc.com
Open the catalog to page 1T40 DUAL LED TRACK STAND Alpha Spectrophotometer Series Laxco Alpha series spectrophotometers measure the amount of light that passes through a medium at a specific wavelength. The amount of light absorbed by the medium is proportional to the concentration of the absorbing material, which is based off from Beer’s Law. The amount of light is either measured in percent transmitted (%T) or the amount absorb (Abs). The Alpha series offer both single & double beam, general purpose instruments designed to meet the needs of the conventional laboratory. They are ideal for various applications such...
Open the catalog to page 2ALPHA SERIES SPECTROPHOTOMETER Specifications Key Features • Standalone units with 2 line LCD displays • Wide range in wavelengths from 400nm to 1000nm • Single beam systems • Digital display to indicated absorbency or transmittance • Visible light spectrophotometer with halogen illumination • Manual intensity adjustment • Single cuvette sample holder • Manually selectable wavelength • Entry level product; perfect for education • Light Source (Halogen Lamp) to supply the light • A monochromator to isolate the wavelength of interest and eliminate the unwanted second order radiation • A...
Open the catalog to page 3ALPHA SERIES SPECTROPHOTOMETER Specifications Key Features • Standalone units with 2 line LCD display • Wide range in wavelengths from 335nm to 1000nm • Single beam systems • Digital display to indicated absorbency or transmittance • Visible light spectrophotometer with halogen illumination • Digital intensity adjustment • Single cuvette sample holder • Manually selectable wavelength • Entry level product; perfect for education • Light Source (Halogen Lamp) to supply the light • A monochromator to isolate the wavelength of interest and eliminate the unwanted second order radiation • A...
Open the catalog to page 4ALPHA SERIES SPECTROPHOTOMETER Specifications Key Features • Standalone units with 2 line LCD display • Wide range in wavelengths from 325nm to 1000nm • Single beam systems • Digital display to indicated absorbency or transmittance • Visible light spectrophotometer with halogen illumination • Digital intensity adjustment • Compartmented single cuvette sample holder (other options available) • Manual selectable wavelength • Built in Thermal printer output port for data curve (printer not included) • Supports up to 200 test points that can be saved onto local memory • Mid level product;...
Open the catalog to page 5ALPHA SERIES SPECTROPHOTOMETER Specifications Key Features • Standalone units with 4 line x 20 characters LCD display • Wide range in wavelengths from 325nm to 1000nm • Single beam systems • Digital display to indicated absorbency or transmittance • Visible light spectrophotometer with halogen illumination • Digital intensity adjustment • Compartmented single cuvette sample holder (other options available) • Digitally selectable wavelength • Built in Thermal printer output port for data curve (printer not included) • Supports up to 200 test points that can be saved onto local memory • Mid...
Open the catalog to page 6ALPHA SERIES SPECTROPHOTOMETER Specifications Key Features • Standalone units with 128 x 64 pixel LCD display • Wide range in wavelengths from 325nm to 1100nm • Single beam systems, Littrow, grating 1200/line/mm • Digital display to indicated absorbency or transmittance • Visible light spectrophotometer with halogen illumination • Digital intensity adjustment • Compartmented single cuvette sample holder (other options available) • Manual selectable wavelength • Built in Thermal printer output port for data curve (printer not included) • Supports up to 200 test points that can be saved onto...
Open the catalog to page 7ALPHA SERIES SPECTROPHOTOMETER Specifications Key Features • Standalone units with 4 line x 20 characters LCD display • Wide range in wavelengths from 200nm to 1000nm • Single beam systems, Littrow, grating 1200/line/mm • Digital display to indicated absorbency or transmittance • UV/Vis light spectrophotometer • Digital intensity adjustment • Compartmented multi cuvette sample holder • Digitally selectable wavelength • Built in Thermal printer output port for data curve (printer not included) • Supports up to 200 test points that can be saved onto local memory • Research grade; perfect for...
Open the catalog to page 8ALPHA SERIES SPECTROPHOTOMETER Specifications Key Features • Standalone units with 4 line x 20 characters LCD display • Wide range in wavelengths from 190nm to 1100nm • Single beam systems, Littrow, grating 1200/line/mm • Advanced quantitative analysis with linear and output port for data curve • UV/Vis light spectrophotometer • DNA/Protein, Kinetic (enzyme reaction rate) & Wavelength Mode • Compartmented multi cuvette sample holder • Digitally selectable wavelength & intensity adjustment • Built in Thermal printer output port for data curve (printer not included) • Supports up to 1000 test...
Open the catalog to page 9ALPHA SERIES SPECTROPHOTOMETER Specifications Key Features • Standalone unit with 320 x 240 pixel graphic LCD display • Wide range in wavelengths from 190nm to 1000nm • Single beam systems, Littrow, grating 1200/line/mm • Advanced re-scaling axis, curve smoothing, zoom, overlap and 1st to 4th derivative for qualitative analysis • UV/Vis light spectrophotometer • Basic photometric, quantitative, DNA/Protein, Kinetic (enzyme reaction rate) & Wavelength Mode • Compartmented multi cuvette sample holder • Digitally selectable wavelength & intensity adjustment • Built in Thermal printer output...
Open the catalog to page 10ALPHA SERIES SPECTROPHOTOMETER Specifications Key Features • Standalone unit with 320 x 240 pixel graphic LCD display • Wide range in wavelengths from 190nm to 1100nm • Dual beam system & Czerny-Turner, grating 1200 line/nm • Advanced quantitative analysis with linear and output port for data curve • UV/Vis light spectrophotometer • DNA/Protein, Kinetic (enzyme reaction rate) & Wavelength Mode • Compartmented multi cuvette sample holder • Digitally selectable wavelength & intensity adjustment • Built in Thermal printer output port for data curve (printer not included) • Supports up to 1000...
Open the catalog to page 11All Laxco Inc catalogs and technical brochures
-
LMI-6000 Series
7 Pages
-
LMC / LMI Series Microscopes
13 Pages
-
LMC-4000 SERIES
6 Pages
-
LMC-3000 SERIES
9 Pages
-
LMC-2000 SERIES
9 Pages
-
LMC-1000 SERIES
6 Pages
-
MicroSpek ™ DSM
6 Pages
-
SeBa™ Pro 5
4 Pages
-
SeBa™ Pro 4
4 Pages
-
SeBa™ 3
4 Pages
-
SeBa™ 2
4 Pages