video corpo

AC500

AC500

AC500

Product catalog summary
Overview
The LECO AC500 Isoperibol Calorimeter is a sophisticated device designed for precise calorific content measurement. It integrates seamlessly with software for data management, report generation, and LIMS compatibility, and can control up to four calorimeters from a single PC.

Unique Design
The AC500 features an integral water-measuring and combustion vessel-filling station, simplifying sample preparation. It is a compact, standalone benchtop unit with a fully integrated circulation system, eliminating the need for additional heaters or coolers. The system uses an electronic thermometer with an accuracy of 0.0001 °C, measuring temperature every six seconds. It also monitors temperature in both the outer jacket and the calorimeter proper, allowing for two-channel correction.

Performance
The AC500 offers high precision across various sample sizes and ambient conditions. It provides results in three modes: Regnault-Pfaundler (20 minutes), Precision (8 minutes), and Predictive (4.5 to 7.5 minutes). It is ASTM/DIN-compliant and quickly determines gross calorific content. The combustion vessel design facilitates easy handling of samples, and an optional string-ignition vessel allows for seamless analysis without fuse wire connections.

Specifications
  • Method: Isoperibol
  • Range: 14000 to 35000 Joules/Charge, 3300 to 8300 Calories/Charge, 13 to 33 Btu/Charge
  • Precision: ≤0.05% RSD
  • Resolution: 1 Btu/lb; 0.1 Cal/g; 0.001 MJ/kg; 0.1 kcal/100 g
  • Analysis Time: 20 min (Regnault-Pfaundler), 8 min (Precision), 4.5 to 7.5 min (Predictive)
  • Temperature Measuring Resolution: 0.0001 °C
  • Gas Requirements: Oxygen 450 psi max; 99.5% purity
  • Environmental Conditions: Operating Temperature: 15 °C to 35 °C; Relative Humidity: 20% to 80%, non-condensing
  • Sound Pressure Level: 50 dBa
  • Electrical Requirements: 115/230 V~, 50/60 Hz, single phase
  • Water Requirements: Distilled water only, pH: 6-8, Dissolved Solids: 0.5 ppm to 100 ppm
  • Required Work Space: Benchtop 32 in W x 31 in D x 26 in H

Additional Information
Various part numbers and configurations are available, including options with different igniter kits and a printer kit. The document emphasizes safety limits for combustion vessel use and advises consulting LECO for the latest specifications.
See more

Catalog excerpts

AC500-1

AC500 Calorimeter ASTM/DIN-compliant, the robust AC500 from LECO quickly determines gross calorific content. Unique Design The AC500 Isoperibol Calorimeter features an integral water-measuring and combustion vessel-filling station simplifying sample preparation. This stand-alone benchtop unit has a fully integrated circulation system, making it compact as well as simple to operate. No additional heaters or coolers are required. The operating system uses an electronic thermometer with an accuracy of 0.0001 °C to measure the temperature every six seconds. The AC500 also features the unique ability to constantly monitor temperature in both the outer jacket and the calorimeter proper, making two-channel correction possible. A High Level of Performance The AC500 achieves high precision across a wide range of sample sizes and ambient conditions. Results may be obtained using a choice of three modes: the traditional Regnault-Pfaundler = 20 minutes, Precision = 8 minutes, or Predictive = 4.5 to 7.5 minutes. Combustion vessel design makes pre-/post-handling of samples trouble-free. LECO’s AC500 software seamlessly manages data, report generation, LIMS compatibility, and can control up to four separate calorimeters through a single PC. Optional string-ignition combustion vessel provides a seamless analysis without fuse wire connection

 Open the catalog to page 1
AC500-2

Specifications Method Range Joules/Charge Analysis Time Regnault-Pfaundler: Precision Mode: Predictive Mode: Acid or % nitrogen, fuse wire, sulfur, moisture, spike weight, ash, and hydrogen Temperature Measuring Resolution Environmental Conditions Relative Humidity: 20 % to 80 %, non-condensing Sound Pressure Level 50 dBa (max reading at operator’s level per IEC/EN 61010-1) Electrical Requirements 115/230 V~ (±10 %; at max load), 50/60 Hz, single phase, 3.2/1.6 A, 1,300 Btu/h Distilled water only, approximately 16 L full capacity. NOTE: Do NOT use deionized water. Water Requirements pH: 6-8;...

 Open the catalog to page 2

All LECO catalogs and technical brochures

  1. RHEN602

    2  Pages

  2. 928 Series

    6  Pages

  3. CS844 Series

    6  Pages

  4. 832 Series

    6  Pages

  5. GDS900

    8  Pages

  6. Pegasus BT 4D

    6  Pages

  7. MX500

    2  Pages

  8. MX400

    2  Pages

  9. PAX-it 2

    2  Pages

  10. SX100M

    2  Pages

  11. LCB3100

    2  Pages

  12. L-PAL3

    2  Pages

  13. TruSpec Micro

    4  Pages

  14. DH603

    4  Pages

  15. AF700

    2  Pages

  16. VX4

    1  Page

  17. AMH55

    6  Pages

  18. EATC Berlin

    8  Pages

  19. 828 Series

    6  Pages

  20. TGM800

    6  Pages

  21. 736 Series

    6  Pages

  22. 836 Series

    6  Pages

  23. eBook Food

    48  Pages

  24. RC612

    4  Pages

  25. CS744

    6  Pages

  26. AC600

    4  Pages

  27. TGA801

    6  Pages

  28. Pegasus BT

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.