Catalog excerpts

Culture Safe CO2 Incubator Touch Range
Open the catalog to page 1
Introduction to LEEC LEEC’s mission statement of “aiming to exceed customer expectations for quality, delivery and cost through continuous improvement and customer interaction” is the philosophy behind the company. The management team operate the ISO 9001 quality models across the various departments. The combination of mission statement and the management system has created a modern, dynamic, forward thinking company. The Touch range of LEEC CO2 incubators have been developed by listening to our customers and using the latest cutting edge technologies. This has helped LEEC to develop a...
Open the catalog to page 2
Frequently Asked Questions Why consider the LEEC Culture Safe versus other brands? LEEC has almost 60 years experience of manufacturing laboratory incubators. LEEC developed the first CO2 incubator that automatically injected and controlled CO2 by the use of a thermal conductivity (T.C.) CO2 detector. LEEC developed and patented this world leading technology at this period in time, hence manufacturing the world’s 1st automatic CO2 incubator. As you would expect from such a forward thinking innovative company, LEEC has continued its relentless R&D programme and now offers world class leading...
Open the catalog to page 3
Easy to use Icon Lead Touch Screen Control System The new state of the art PID controller is designed to be as user friendly as possible, allowing the user to quickly access the required menus via a simple icon navigation system. On board text and graphical data logging of temperature, C02 and O2 (if fitted) with a minimum of 72 hours graphical data logging and 100 text event logs, all conveniently saved as .csv files for viewing in MS Excel® from a removable SD card. SD - LEEC offers the SD card facility of data collection
Open the catalog to page 4
World's first 200oc Sterilisation Cy- Independent evaluation of effectiveness of LEEC 200oc sterilisation cycle against all spores and bacteria commonly associated to be possibly present in laboratory incubators: The LEEC Culture Safe CO2 incubator has been independently evaluated for the effectiveness of its 200oC sterilisation cycle. The sterilisation cycle was proven to be effective against the stubborn Geobacillus stearothermophilus spores. atcc 12980 dried on coupons (Apex Laboratories, Inc. Lot No. K00001) Aspergillus spores ATCC 16404 (formally Aspergillus niger) and Bacillus...
Open the catalog to page 5
Typical recovery graphs for a LEEC Culture Safe Touch 50S model with 3 inner door option fitted: The graphs below in Figure 1, illustrate typical recovery times for *temperature, *%CO2 and *%RH, after the bottom compartmental glass door is opened for the duration of 30 seconds and then closed. *Quicker recovery times are achievable with a 6 Inner door option. Typical Recovery T50S Multidoor 3 (Bottom Door Opened for 30 Seconds) Temp Recovery Time (Minutes) Typical recovery graphs for a LEEC Culture Safe Touch T190S model with a standard single glass door fitted: The graphs below in Figure...
Open the catalog to page 6
The benefits of LEEC incubators being fanless • Significantly reduced risk of contamination • Zero vibration: eradicates any possibility of cell edging effect • Significantly less evaporation; minimise loss of water in the water tray, hence less risk of sample evaporation and possible desiccation • Considerably easier to clean • Very easy and quick to remove shelves and shelf racks for ease of cleaning • Considerably more useable space, no ducting or built in hepa to minimise useable space • No hidden areas or crevasses that can be difficult to clean • No fan maintenance • No extra costs to...
Open the catalog to page 7
Lifting Handles Rear Wheels, Easy Placement Low profile shelf racking, maximises shelf space C02 Touch T190 Inner Glass Door Latch Water Tray - separate heating element for increased control of humidity
Open the catalog to page 8
Touch T190S C02 incubator with 8 inner glass door option fitted. Touch T50S C02 incubator with 3 Inner glass door option fitted Shelving - Anti tilt easily removable shelf dividers, built in handle lip Robust Hinges Easy to clean robust heavy duty outer door seal Glass Door Hinged Internally Inner Chamber & Racking - Drawn Chamber - Seamless Design. Easy to Remove - Rounded Corners Inner Door Seal Airtight - Round Corners
Open the catalog to page 9
Options • Stacking Stands • Dual Temp Control • Floor Stands • 8 Inner door option
Open the catalog to page 10
TECHNICAL SPECIFICATIONS CULTURE SAFE TOUCH 50 TEMPERATURE MANAGEMENT 1-19% 02 options % RH Display Dual Temp Control 3 Inner door option LEEC Bench Top Touch 50 & Touch 50S CO2 Incubators 50 Litres Bench Top CO2 Incubator Ideal for I.V.F and stem cell applications Easy to clean and replaceable inner door seal Ideal for research of critical samples Minimised loss of conditions on door opening 3 inner or 6 inner door options available for quicker recovery 1-19% 02 options available %RH Display option available - Power Switch On/Off Ethernet Port (optional) Retransmit Port 4-20mA (optional) ■...
Open the catalog to page 11
Other LEEC Products Precision Range Culture Safe CO2 Warming Cabinet Drying Cabinets LEEC Limited, Private Road No. 7, Colwick Industrial Estate, Nottingham, NG4 2AJ t. +44 (0)115 961 6222 f.+44 (0)115 961 6680 sales@leec.co.uk www.leec.co.uk Microbiological Incubator
Open the catalog to page 12All LEEC catalogs and technical brochures
-
Post Mortem Table
2 Pages
-
Cremator Charger
4 Pages
-
PST 65
2 Pages
-
P33
1 Pages
-
embalming station
1 Pages
-
Lightweight Stretchers
1 Pages
-
Coffin Bier
1 Pages
-
Stretcher Covers
1 Pages
-
Combination Stretchers
1 Pages
-
First Call One Man Loader
1 Pages
-
Multilevel Removal Trolley
1 Pages
-
Hydraulic Stacking Trolley
2 Pages
-
Mobile Instrument Trolley
2 Pages
-
Low Loading Trolley
2 Pages
-
Refrigerated Body Storage
1 Pages
-
Mortuary Trays
1 Pages
-
Body Identification System
2 Pages
-
LEEC RCS
2 Pages
-
Autopsy solid top Pedestal
1 Pages
-
Dissecting trolley
2 Pages
-
Ventilated Specimen Stores
6 Pages
-
Ultrasonic Humidity Cabinets
2 Pages
-
LEEC Precision Incubator
1 Pages
-
Research CO2 Incubators
2 Pages
-
Viewing Trolley
1 Pages
-
LEEC Autopsy tables brochure
1 Pages
-
Foetal Storage
1 Pages
-
Hydraulic Stacking Trollet
2 Pages
-
Hydraulic Embalming Trolley
2 Pages
-
Mobile Racking
1 Pages
-
Body Storage Trays
1 Pages
-
Lift Assist brouchure.
2 Pages
-
LEEC Easy Fit Cool Zone
2 Pages
-
Warming Cabinets
2 Pages
-
Drying Cabinet
2 Pages
-
Classic Incubator brochure
2 Pages