Group: Danaher
Catalog excerpts
LEICA EM ICE High Pressure Freezer
Open the catalog to page 1“Leica EM ICE is a platform for game-changing discoveries. It is the only high pressure freezer with fully integrated light stimulation. The only tool that can capture dynamic phenomenon on a millisecond scale. It opens new possibilities for researchers in life science and industry.
Open the catalog to page 2HIGH PRESSURE FREEZER LEICA EM ICE HIGH PRESSURE FREEZING WITH LIGHT STIMULATION AND/OR ELECTRICAL STIMULATION
Open the catalog to page 3C.elegans, courtesy of Elly van Donselaar, Martin Harterink and Karin Vocking, Utrecht University, Netherlands WHY HIGH PRESSURE FREEZING? High Pressure Freezing arrests aqueous samples in their native state to deliver the best possible sample preservation. Currently cryofixation is the only way to fix cellular constituents without introducing significant structural alterations.
Open the catalog to page 4Leica EM ICE for high pressure freezing with light stimulation Leica EM VCM for sample transfer to ... ... Leica EM ACE600 to fracture and coat the sample to ... ... Leica EM VCT500 for shuttle transfer to the cryo SEM Cryo-SEM analysis Revealing changes in the fine structure of a suncream lotion frozen after millisecond UV light stimulation WHY HIGH PRESSURE FREEZING WITH LIGHT STIMULATION? The synchronization of light stimulation and high pressure freezing allows the visualization of highly dynamic process such as synaptic vesicle fusion at a nanometer resolution and millisecond...
Open the catalog to page 5COMPLETELY INTEGRATED LIGHT STIMULATION Light source > LED light modules with 5 different wave lengths (red, blue, green, UV, amber). > Automatic recognition of the connected LED module by the instrument software. > Easy one-click connection. Experiment parameters > Software-integrated programming offers a range of parameters to enable the design of your experiment. > All details of a light stimulation experiment are incorporated in the log file.
Open the catalog to page 6HOLDS THE PROMISE FOR A BRIGHTER FUTURE Symmetric synapse. Dr. Shuwen Chang, Charité Universitätsmedizin, Berlin, Germany “Electron microscopy only captures a static image of a cell. What is the cell doing? What is the true sequence of events in a cellular process? We can make flip books from our micrographs that tell a story, but their arrangement can be influenced by the story we want to tell. With the advent of optogenetic tools a flash of light can trigger dynamic cellular events such as neurotransmission. By coupling a flash of light with rapid high-pressure freezing, regulated vesicle...
Open the catalog to page 7Mouse Hippocampal Neurons, Dr. Shigeki Watanabe, Johns Hopkins University WHY HIGH PRESSURE FREEZING WITH ELECTRICAL STIMULATION? Membrane trafficking events at neuronal synapses are the basis of every memory, every emotion. Understanding this highly dynamic event is anything but trivial. The combination of well-established electrophysiology research methods and the technology that allows for millisecond precision in sample preservation is the only tool that may bring the revelation of many unanswered questions such as “How are synaptic vesicles recycled?” Freeze the moment of your discovery
Open the catalog to page 8E - Stimulation middle plate check Charge plate Middle plate Assemble the Electrical Stimulation components Program your experiment Load the samples Charge the Middle plate/PSP print Freeze HOW DOES HIGH PRESSURE FREEZING WITH ELECTRICAL STIMULATION WORK? The secret to our success is in the specially designed middle plate for ES experiments. It is a PCB (printed circuit board) which can be charged with electricity. This electricity is stored in capacitors and can only be released inside of the high pressure chamber. The release of electrical current is induced by a light-sensitive switch...
Open the catalog to page 9DISCOVER LEICA EM ICE UNIQUE FEATURES Only 1 second from loading the sample in the carrier to frozen Only 1 minute recovery time between freezing cycles Only 20 minutes to cool down and ready to use Only 30 liters LN2 daily consumption, including cooling down No alcohol or additional synchronization fluids used Upgradable to light stimulation mode at any time at your work place Upgradable to electrical stimulation mode at any time at your work place
Open the catalog to page 10Neuron, courtesy of Elly van Donselaar, Martin Harterink and Karin Vocking, Utrecht University, Netherlands FOCUS ON YOUR SAMPLE One move, fully automated specimen loading >> The cartridge assembly and the freezing process is triggered automatically by closing the cover of the loading station. Concentrate on the sample, not on the instrument. ONE SAMPLE DEWAR – MANY POSSIBILITIES Work quickly and efficiently with the Leica EM ICE >> Programmed rotation: Software integrated programming of sample position, name and number in the specimen Dewar. >> Three separate positions: Allows for three...
Open the catalog to page 11qualityaustria SYSTEM CERTIFIED ISO 9001:2008 No.00805/0IS014001:2004 No.02783/0 Leica Mikrosysteme GmbH | Vienna, Austria T +43 1 486 8050-0 | F +43 1 486 8050-30 www.leica-microsystems.com Leica EM ICE Brochure •English •06/2017 • Copyright © by Leica Mikrosysteme GmbH, Vienna, Austria, 2017. Subject to modifications. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH
Open the catalog to page 12All Leica Microsystems catalogs and technical brochures
-
M844 F40/F20
16 Pages
-
EnFocus
12 Pages
-
M822 F40 / F20
12 Pages
-
M320 for ENT
12 Pages
-
ARveo 8
16 Pages
-
M320 Dental Brochure
12 Pages
-
Emspira 3
4 Pages
-
Exalta
2 Pages
-
FLEXACAM C1
4 Pages
-
EM KMR3
8 Pages
-
EM UC7
16 Pages
-
EM TRIM2
8 Pages
-
EM RAPID
8 Pages
-
EM TXP
10 Pages
-
EM RES102
12 Pages
-
EM TIC 3X
16 Pages
-
TL4000 BFDF
16 Pages
-
F12 I floor stand
6 Pages
-
XL Stand
4 Pages
-
TL3000 Ergo & TL5000 Ergo
4 Pages
-
KL300 LED
8 Pages
-
LED1000
16 Pages
-
LED3000 BLI
20 Pages
-
LED5000 NVI
20 Pages
-
LED3000 NVI
20 Pages
-
LED3000 DI
20 Pages
-
LED5000 HDI
20 Pages
-
LED5000 CXI
20 Pages
-
LED2500
8 Pages
-
LED5000 MCI
20 Pages
-
LED3000 MCI
20 Pages
-
LED5000 SLI
20 Pages
-
LED3000 SLI
20 Pages
-
LED2000
8 Pages
-
LED5000 RL
20 Pages
-
LED3000 RL
20 Pages
-
MZ10 F
4 Pages
-
M165 FC
16 Pages
-
M205 FCA, M205 FA
16 Pages
-
M125 C, M165 C, M205 C, M205 A
12 Pages
-
A60 F, A60 S
16 Pages
-
M50, M60, M80
12 Pages
-
DVM6
16 Pages
-
HCS A
20 Pages
-
TCS SPE
20 Pages
-
DFC450 C
6 Pages
-
DFC295
6 Pages
-
MC170 HD
6 Pages
-
DFC3000 G
6 Pages
-
DMC4500
4 Pages
-
ICC50 W, ICC50 E
6 Pages
-
DFC7000 T, DFC7000 GT
4 Pages
-
DFC9000
2 Pages
-
IC90 E
6 Pages
-
DMC6200
8 Pages
-
DMC5400
8 Pages
-
SFL7000
4 Pages
-
EL6000
4 Pages
-
SFL100
4 Pages
-
SFL4000
4 Pages
-
DMi8 S Platform
2 Pages
-
THUNDER Imager Live Cell
2 Pages
-
DMi8 M / C / A
12 Pages
-
DM IL LED
12 Pages
-
DMi1
6 Pages
-
DM3 XL
7 Pages
-
FS M
4 Pages
-
FS C
4 Pages
-
FS CB
4 Pages
-
DM3000, DM3000 LED
16 Pages
-
DM750 M
12 Pages
-
DM750
12 Pages
-
DM500
12 Pages
-
DM300
8 Pages
-
DM12000 M
8 Pages
-
DM8000 M
8 Pages
-
DM1750 M
12 Pages
-
DM4 M, DM6 M
12 Pages
-
DM4 P, DM2700 P, DM750 P
12 Pages
-
DM2000, DM2000 LED
16 Pages
-
DM1000
16 Pages
-
DCM8
16 Pages
-
DM1000 LED
16 Pages
-
DM2500
16 Pages
-
DM4 B & DM6 B
16 Pages
-
DM6 M LIBS
2 Pages
-
S9 Series
12 Pages
-
Z6 APO
16 Pages
-
Z16 APO
16 Pages
-
Leica M530 OHX for ENT
4 Pages
-
M620 F20
8 Pages
-
M220 F12
8 Pages
-
Leica Application Suite X
4 Pages
-
Proveo 8
16 Pages
-
M525 F20
12 Pages
-
EnVisu Leica Handheld OCT
8 Pages
-
PROvido
8 Pages
-
Leica M530 OHX
16 Pages
-
Leica TCS SP8 STED 3X
24 Pages
-
Leica TCS SP8 Objective
24 Pages
-
Leica AOBS
16 Pages
-
Leica DMC2900
6 Pages
-
Leica DMshare
2 Pages
-
Leica_DMshare_ICC50-Flyer_en
2 Pages
-
Leica_DMshare_EC3-Flyer_en
2 Pages
-
Leica_SL801-Flyer
2 Pages
-
Leica_SCN400-Flyer_Clinical
2 Pages
-
DM2700 M
12 Pages
-
Leica_SR_GSD-Brochure
10 Pages
-
Leica_AF6000-Brochure
16 Pages
-
Leica motCorr-Flyer_EN
4 Pages
-
Leica TCS SP8-Flyer
2 Pages
-
Leica TCS SP8-Brochure
40 Pages
-
Leica TCS SP8 X-Flyer
2 Pages
-
Leica TCS SP8 STED-Flyer
2 Pages
-
Leica TCS SP8 HyD-Flyer
2 Pages