Group: Danaher
Catalog excerpts
A Decade of Super-Resolution Innovation Working with passion for the global research community: The TCS SP8 STED 3X marks one decade of innovative super-resolution technology by Leica Microsystems - providing quality data and efficient processes foryour science. Dual color for TCS SP8 STED TCS SP8 TCS STED (CW) and gated STED STED 3X LASER RADIATION VISIBLE AND INVISIBLE - CLASS 3B AVOID DIRECT EXPOSURE TO BEAM LASER RADIATION VISIBLE AND INVISIBLE - CLASS 4 AVOID EYE OB SKIN EXPOSURE TO DIRECT OR SCAITEBED RAOIATION Order no.: English 1593003011 ■ Copyright © by Leica Microsystems CMS GmbH, Mannheim, Germany, 2014 Subject to modifications. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH
Open the catalog to page 1Your Next Dimension
Open the catalog to page 2Welcome To Your Next Dimension! The new TCS SP8 STED 3X opens up new dimensions for your research: Discover the possibilities of super-resolution in real 3D.
Open the catalog to page 4Pure Physics, More Efficiency The new TCS SP8 STED 3X strengthens your science: ››Tunable and direct super-resolution in x, y and z reveal smallest details ›› Multiple STED lines open up the full spectrum of visible light ›› Gated detection improves resolution and increases live cell capabilities ›› STED WHITE objective has optimal color correction for the full spectrum ›› Auto beam alignment provides stability and reliability ›› Modular concept based on the TCS SP8 allows you to upgrade at any time ›› Smart STED Wizard intuitively controls your experiments ›› Huygens deconvolution gets...
Open the catalog to page 6TCS SP8 STED 3X – Here’s Your Next Dimension! Here’s Your Next Dimension! STED microscopy by Leica Microsystems has revolutionized the study of subcellular a rchitecture and cell dynamics at the nanoscale. The fully integrated STED (STimulated Emission Depletion) system meets the requirements of daily research and provides fast, intuitive, and purely optical access to structural details far beyond the diffraction limit. Gated STED substantially improves resolution to below 50 nm and increases live cell viability. Now, the next generation of STED, the TCS SP8 STED 3X, broadens the scope of...
Open the catalog to page 8Pure Physics, More Reliability STimulated Emission Depletion imaging reaches lateral resolution below 50 nm in true optical sections by downscaling the spot from where fluorescence is generated. STED is pure physics: What you see is what you get. The principle Super-resolution – fast and direct The basic principle of STED, which was A phase mask filter determines the area STED technology provides fast and direct first described by Stefan Hell in 1994 , is in the focus plane where STED light is access to structural details at the nano- simple. The effective focal spot scanning dominant, e.g....
Open the catalog to page 9TCS SP8 STED 3X – Pure Physics, More Reliability STED Intensity Achieved resolution (left) correlates with STED laser power (right). Right panel: STED donut with area of stimulated emission in red, area of fluorescence in green. Resolution improvement achieved by STED microscopy is purely optical and does not rely on mathematics. Of course, you can further process your images with deconvolution. STED allows you to directly compare the outcome with the raw data and makes your results more reliable. Don’t waste time with artifacts! Key Publications ›› Hell, S. W. & Wichmann, J. Breaking the...
Open the catalog to page 10Life Happens in 3D – Now Observe its Detail Immunofluorescence stain of Golgi marker in HeLa cells: Surface rendered 3D reconstruction after Huygens deconvolution of a z stack (20 planes), 3D donut 100%. STED data (green) show a clear resolution increase compared to the confocal result (red). Data courtesy of Dr. Timo Zimmermann, Center for Genomic Regulation, Barcelona, Spain.
Open the catalog to page 11xy view xz view Histone H3-Alexa 568 in HeLa cells: The highest lateral resolution increase is achieved by the vortex donut, maximal resolution increase in x, y and z by 3D STED. Note the loss of structures of objects that are not in the super-resolved focus plane when using 3D STED. 3D STED also achieves an increase of resolution in the xy dimension. Confocal x axis z axis XZ axis plot of Histone H3-Alexa 568 in HeLa cells. 0% z donut allocates all STED light to the vortex donut resulting in maximal resolution increase in x and y, but not in z compared to confocal microscopy. A small focal...
Open the catalog to page 12Push the Boundaries! Organisms, tissues and cells are three dimensional. To investigate cellular processes you want to consider all directions. The new TCS SP8 STED 3X allows you to extend the boundaries of super-resolution in all dimensions. Discover more details in X, Y and Z Engineer your PSF to your science With TCS SP8 STED 3X, two STED light paths generate TCS SP8 STED 3X gives you the possibility to match the different STED patterns (see figure below). For best resolution resolution of your microscope in all dimensions to your scientific in x and y the light is allocated to the STED...
Open the catalog to page 13Immunostaining of endosomal marker (Lamp M) in TCS SP8 STED 3X – Subchapter 13 HeLa cells. Note the loss of structures out of superresolved focal plane (white arrows) in the middle compared to confocal images. Courtesy of Shem Johnson, University of Geneva, Switzerland. gSTED with maximum z resolution Push the limits even further The powerful Huygens STED deconvolution package, exclusively supplied with every TCS SP8 STED 3X system, helps to improve your data. Huygens decreases noise levels dramatically and also enhances resolution in x, y and z. After deconvolution of STED data, even...
Open the catalog to page 14See the Full Spectrum of Life Seeing subcellular structures in nanoscopic detail opens a new world to scientists. Multicolor applications give access to detailed information about the interrelationships of various structures. The new STED 3X module offers multiple STED laser lines at different wavelengths in one instrument. Super-resolved colocalization studies have never been so easy. Tunable spectral super-resolution – the freedom to choose Super-resolution and standard labeling strategies are not mutually exclusive. A broad variety of popular dyes and fluorescent proteins in the green...
Open the catalog to page 15All Leica Microsystems catalogs and technical brochures
-
M844 F40/F20
16 Pages
-
EnFocus
12 Pages
-
M822 F40 / F20
12 Pages
-
M320 for ENT
12 Pages
-
ARveo 8
16 Pages
-
M320 Dental Brochure
12 Pages
-
Emspira 3
4 Pages
-
Exalta
2 Pages
-
FLEXACAM C1
4 Pages
-
EM KMR3
8 Pages
-
EM UC7
16 Pages
-
EM TRIM2
8 Pages
-
EM RAPID
8 Pages
-
EM ICE
12 Pages
-
EM TXP
10 Pages
-
EM RES102
12 Pages
-
EM TIC 3X
16 Pages
-
TL4000 BFDF
16 Pages
-
F12 I floor stand
6 Pages
-
XL Stand
4 Pages
-
TL3000 Ergo & TL5000 Ergo
4 Pages
-
KL300 LED
8 Pages
-
LED1000
16 Pages
-
LED3000 BLI
20 Pages
-
LED5000 NVI
20 Pages
-
LED3000 NVI
20 Pages
-
LED3000 DI
20 Pages
-
LED5000 HDI
20 Pages
-
LED5000 CXI
20 Pages
-
LED2500
8 Pages
-
LED5000 MCI
20 Pages
-
LED3000 MCI
20 Pages
-
LED5000 SLI
20 Pages
-
LED3000 SLI
20 Pages
-
LED2000
8 Pages
-
LED5000 RL
20 Pages
-
LED3000 RL
20 Pages
-
MZ10 F
4 Pages
-
M165 FC
16 Pages
-
M205 FCA, M205 FA
16 Pages
-
M125 C, M165 C, M205 C, M205 A
12 Pages
-
A60 F, A60 S
16 Pages
-
M50, M60, M80
12 Pages
-
DVM6
16 Pages
-
HCS A
20 Pages
-
TCS SPE
20 Pages
-
DFC450 C
6 Pages
-
DFC295
6 Pages
-
MC170 HD
6 Pages
-
DFC3000 G
6 Pages
-
DMC4500
4 Pages
-
ICC50 W, ICC50 E
6 Pages
-
DFC7000 T, DFC7000 GT
4 Pages
-
DFC9000
2 Pages
-
IC90 E
6 Pages
-
DMC6200
8 Pages
-
DMC5400
8 Pages
-
SFL7000
4 Pages
-
EL6000
4 Pages
-
SFL100
4 Pages
-
SFL4000
4 Pages
-
DMi8 S Platform
2 Pages
-
THUNDER Imager Live Cell
2 Pages
-
DMi8 M / C / A
12 Pages
-
DM IL LED
12 Pages
-
DMi1
6 Pages
-
DM3 XL
7 Pages
-
FS M
4 Pages
-
FS C
4 Pages
-
FS CB
4 Pages
-
DM3000, DM3000 LED
16 Pages
-
DM750 M
12 Pages
-
DM750
12 Pages
-
DM500
12 Pages
-
DM300
8 Pages
-
DM12000 M
8 Pages
-
DM8000 M
8 Pages
-
DM1750 M
12 Pages
-
DM4 M, DM6 M
12 Pages
-
DM4 P, DM2700 P, DM750 P
12 Pages
-
DM2000, DM2000 LED
16 Pages
-
DM1000
16 Pages
-
DCM8
16 Pages
-
DM1000 LED
16 Pages
-
DM2500
16 Pages
-
DM4 B & DM6 B
16 Pages
-
DM6 M LIBS
2 Pages
-
S9 Series
12 Pages
-
Z6 APO
16 Pages
-
Z16 APO
16 Pages
-
Leica M530 OHX for ENT
4 Pages
-
M620 F20
8 Pages
-
M220 F12
8 Pages
-
Leica Application Suite X
4 Pages
-
Proveo 8
16 Pages
-
M525 F20
12 Pages
-
EnVisu Leica Handheld OCT
8 Pages
-
PROvido
8 Pages
-
Leica M530 OHX
16 Pages
-
Leica TCS SP8 Objective
24 Pages
-
Leica AOBS
16 Pages
-
Leica DMC2900
6 Pages
-
Leica DMshare
2 Pages
-
Leica_DMshare_ICC50-Flyer_en
2 Pages
-
Leica_DMshare_EC3-Flyer_en
2 Pages
-
Leica_SL801-Flyer
2 Pages
-
Leica_SCN400-Flyer_Clinical
2 Pages
-
DM2700 M
12 Pages
-
Leica_SR_GSD-Brochure
10 Pages
-
Leica_AF6000-Brochure
16 Pages
-
Leica motCorr-Flyer_EN
4 Pages
-
Leica TCS SP8-Flyer
2 Pages
-
Leica TCS SP8-Brochure
40 Pages
-
Leica TCS SP8 X-Flyer
2 Pages
-
Leica TCS SP8 STED-Flyer
2 Pages
-
Leica TCS SP8 HyD-Flyer
2 Pages