video corpo

Leica TCS SP8 STED 3X
24Pages

{{requestButtons}}

Catalog excerpts

Leica TCS SP8 STED 3X - 1

A Decade of Super-Resolution Innovation Working with passion for the global research community: The TCS SP8 STED 3X marks one decade of innovative super-resolution technology by Leica Microsystems - providing quality data and efficient processes foryour science. Dual color for TCS SP8 STED TCS SP8 TCS STED (CW) and gated STED STED 3X LASER RADIATION VISIBLE AND INVISIBLE - CLASS 3B AVOID DIRECT EXPOSURE TO BEAM LASER RADIATION VISIBLE AND INVISIBLE - CLASS 4 AVOID EYE OB SKIN EXPOSURE TO DIRECT OR SCAITEBED RAOIATION Order no.: English 1593003011 ■ Copyright © by Leica Microsystems CMS GmbH, Mannheim, Germany, 2014 Subject to modifications. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH

Open the catalog to page 1
Leica TCS SP8 STED 3X - 2

Your Next Dimension

Open the catalog to page 2
Leica TCS SP8 STED 3X - 4

Welcome To Your Next Dimension! The new TCS SP8 STED 3X opens up new dimensions for your research: Discover the possibilities of super-resolution in real 3D.

Open the catalog to page 4
Leica TCS SP8 STED 3X - 6

Pure Physics, More Efficiency The new TCS SP8 STED 3X strengthens your science: ››Tunable and direct super-resolution in x, y and z reveal smallest details ›› Multiple STED lines open up the full spectrum of visible light ›› Gated detection improves resolution and increases live cell capabilities ›› STED WHITE objective has optimal color correction for the full spectrum ›› Auto beam alignment provides stability and reliability ›› Modular concept based on the TCS SP8 allows you to upgrade at any time ›› Smart STED Wizard intuitively controls your experiments ›› Huygens deconvolution gets...

Open the catalog to page 6
Leica TCS SP8 STED 3X - 8

TCS SP8 STED 3X – Here’s Your Next Dimension! Here’s Your Next Dimension! STED microscopy by Leica Microsystems has revolutionized the study of subcellular a ­ rchitecture and cell dynamics at the nanoscale. The fully integrated STED (STimulated Emission Depletion) system meets the requirements of daily research and provides fast, intuitive, and purely optical access to structural details far beyond the diffraction limit. Gated STED substantially improves resolution to below 50 nm and increases live cell viability. Now, the next generation of STED, the TCS SP8 STED 3X, broadens the scope of...

Open the catalog to page 8
Leica TCS SP8 STED 3X - 9

Pure Physics, More Reliability STimulated Emission Depletion imaging reaches lateral resolution below 50 nm in true optical sections by downscaling the spot from where fluorescence is generated. STED is pure physics: What you see is what you get. The principle Super-resolution – fast and direct The basic principle of STED, which was A phase mask filter determines the area STED technology provides fast and direct first described by Stefan Hell in 1994 , is in the focus plane where STED light is access to structural details at the nano- simple. The effective focal spot scanning dominant, e.g....

Open the catalog to page 9
Leica TCS SP8 STED 3X - 10

TCS SP8 STED 3X – Pure Physics, More Reliability STED Intensity Achieved resolution (left) correlates with STED laser power (right). Right panel: STED donut with area of stimulated emission in red, area of fluorescence in green. Resolution improvement achieved by STED microscopy is purely optical and does not rely on mathematics. Of course, you can further process your images with deconvolution. STED allows you to directly compare the outcome with the raw data and makes your results more reliable. Don’t waste time with artifacts! Key Publications ›› Hell, S. W. & Wichmann, J. Breaking the...

Open the catalog to page 10
Leica TCS SP8 STED 3X - 11

Life Happens in 3D – Now Observe its Detail Immunofluorescence stain of Golgi marker in HeLa cells: Surface rendered 3D reconstruction after Huygens deconvolution of a z stack (20 planes), 3D donut 100%. STED data (green) show a clear resolution increase compared to the confocal result (red). Data courtesy of Dr. Timo Zimmermann, Center for Genomic Regulation, Barcelona, Spain.

Open the catalog to page 11
Leica TCS SP8 STED 3X - 12

xy view xz view Histone H3-Alexa 568 in HeLa cells: The highest lateral resolution increase is achieved by the vortex donut, maximal resolution increase in x, y and z by 3D STED. Note the loss of structures of objects that are not in the super-resolved focus plane when using 3D STED. 3D STED also achieves an increase of resolution in the xy dimension. Confocal x axis z axis XZ axis plot of Histone H3-Alexa 568 in HeLa cells. 0% z donut allocates all STED light to the vortex donut resulting in maximal resolution increase in x and y, but not in z compared to confocal microscopy. A small focal...

Open the catalog to page 12
Leica TCS SP8 STED 3X - 13

Push the Boundaries! Organisms, tissues and cells are three dimensional. To investigate cellular processes you want to consider all directions. The new TCS SP8 STED 3X allows you to extend the boundaries of super-resolution in all dimensions. Discover more details in X, Y and Z Engineer your PSF to your science With TCS SP8 STED 3X, two STED light paths generate TCS SP8 STED 3X gives you the possibility to match the different STED patterns (see figure below). For best resolution resolution of your microscope in all dimensions to your scientific in x and y the light is allocated to the STED...

Open the catalog to page 13
Leica TCS SP8 STED 3X - 14

Immunostaining of endosomal marker (Lamp M) in TCS SP8 STED 3X – Subchapter 13 HeLa cells. Note the loss of structures out of superresolved focal plane (white arrows) in the middle compared to confocal images. Courtesy of Shem Johnson, University of Geneva, Switzerland. gSTED with maximum z resolution Push the limits even further The powerful Huygens STED deconvolution package, exclusively supplied with every TCS SP8 STED 3X system, helps to improve your data. Huygens decreases noise levels dramatically and also enhances resolution in x, y and z. After deconvolution of STED data, even...

Open the catalog to page 14
Leica TCS SP8 STED 3X - 15

See the Full Spectrum of Life Seeing subcellular structures in nanoscopic detail opens a new world to scientists. Multicolor applications give access to detailed information about the interrelationships of various structures. The new STED 3X module offers multiple STED laser lines at different wavelengths in one instrument. Super-resolved colocalization studies have never been so easy. Tunable spectral super-resolution – the freedom to choose Super-resolution and standard labeling strategies are not mutually exclusive. A broad variety of popular dyes and fluorescent proteins in the green...

Open the catalog to page 15

All Leica Microsystems catalogs and technical brochures

  1. M844 F40/F20

    16 Pages

  2. EnFocus

    12 Pages

  3. M822 F40 / F20

    12 Pages

  4. M320 for ENT

    12 Pages

  5. ARveo 8

    16 Pages

  6. Emspira 3

    4 Pages

  7. Exalta

    2 Pages

  8. FLEXACAM C1

    4 Pages

  9. EM KMR3

    8 Pages

  10. EM UC7

    16 Pages

  11. EM TRIM2

    8 Pages

  12. EM RAPID

    8 Pages

  13. EM ICE

    12 Pages

  14. EM TXP

    10 Pages

  15. EM RES102

    12 Pages

  16. EM TIC 3X

    16 Pages

  17. TL4000 BFDF

    16 Pages

  18. XL Stand

    4 Pages

  19. KL300 LED

    8 Pages

  20. LED1000

    16 Pages

  21. LED3000 BLI

    20 Pages

  22. LED5000 NVI

    20 Pages

  23. LED3000 NVI

    20 Pages

  24. LED3000 DI

    20 Pages

  25. LED5000 HDI

    20 Pages

  26. LED5000 CXI

    20 Pages

  27. LED2500

    8 Pages

  28. LED5000 MCI

    20 Pages

  29. LED3000 MCI

    20 Pages

  30. LED5000 SLI

    20 Pages

  31. LED3000 SLI

    20 Pages

  32. LED2000

    8 Pages

  33. LED5000 RL

    20 Pages

  34. LED3000 RL

    20 Pages

  35. MZ10 F

    4 Pages

  36. M165 FC

    16 Pages

  37. A60 F, A60 S

    16 Pages

  38. M50, M60, M80

    12 Pages

  39. DVM6

    16 Pages

  40. HCS A

    20 Pages

  41. TCS SPE

    20 Pages

  42. DFC450 C

    6 Pages

  43. DFC295

    6 Pages

  44. MC170 HD

    6 Pages

  45. DFC3000 G

    6 Pages

  46. DMC4500

    4 Pages

  47. DFC9000

    2 Pages

  48. IC90 E

    6 Pages

  49. DMC6200

    8 Pages

  50. DMC5400

    8 Pages

  51. SFL7000

    4 Pages

  52. EL6000

    4 Pages

  53. SFL100

    4 Pages

  54. SFL4000

    4 Pages

  55. DMi8 M / C / A

    12 Pages

  56. DM IL LED

    12 Pages

  57. DMi1

    6 Pages

  58. DM3 XL

    7 Pages

  59. FS M

    4 Pages

  60. FS C

    4 Pages

  61. FS CB

    4 Pages

  62. DM750 M

    12 Pages

  63. DM750

    12 Pages

  64. DM500

    12 Pages

  65. DM300

    8 Pages

  66. DM12000 M

    8 Pages

  67. DM8000 M

    8 Pages

  68. DM1750 M

    12 Pages

  69. DM4 M, DM6 M

    12 Pages

  70. DM1000

    16 Pages

  71. DCM8

    16 Pages

  72. DM1000 LED

    16 Pages

  73. DM2500

    16 Pages

  74. DM4 B & DM6 B

    16 Pages

  75. DM6 M LIBS

    2 Pages

  76. S9 Series

    12 Pages

  77. Z6 APO

    16 Pages

  78. Z16 APO

    16 Pages

  79. M620 F20

    8 Pages

  80. M220 F12

    8 Pages

  81. Proveo 8

    16 Pages

  82. M525 F20

    12 Pages

  83. PROvido

    8 Pages

  84. Leica M530 OHX

    16 Pages

  85. Leica AOBS

    16 Pages

  86. DM2700 M

    12 Pages