IMPLANTOLOGY - 1

product catalogue eighth Italian edition seventh English edition ORTHODONTICS and IMPLANTOLOGY Via P. a Quaracchi, 50 50019 Sesto Fiorentino Firenze Italy Phone +39.055.30.44.620 Fax +39.055.30.44.05 info@leone.it www.leone.it

Open the catalog to page 1
IMPLANTOLOGY - 2

LEONE COMPANY In 1934 the history of Leone originated from a small handicraft activity and today it is an industrial reality of high technological and commercial level. The productive and industrial area spreads out over a surface of around 10.000 sq. m., where 125 people operate. QUALITY PRODUCT CONTROL Most of the remarkable investments of the company are reserved to the Centre for Biotechnological Research “Marco Pozzi”, which is located inside the company. Studies on materials, surfaces and technical analysis for new products are carried out here. The collaboration with either Italian...

Open the catalog to page 2
IMPLANTOLOGY - 3

LEONE S.p.a. ORTHODONTICS and IMPLANTOLOGY CUSTOMER SERVICE EDUCATION, TRAINING UPGRADING LEONE is working non stop to satisfy the customer’s expectations and is represented with dealers in 60 countries. A careful pre-sale and post-sale customer assistance is provided by qualified technical and commercial staff to meet any requirement. Finished and semi-finished products are stocked and organized by vertical lift automatic cabinets allowing a rationalization of the space and a fully computer based processing of the orders. Standard orders are shipped within 24 hours in Italy and 5-6 working...

Open the catalog to page 3
IMPLANTOLOGY - 4

LEONE IMPLANT SYSTEM PRODUCT CATALOGUE ALPHABETICAL INDEX SURGICAL PROCEDURE DISCLAIMER AND TREATMENT PLANNING IMPLANT PACKAGING 1. preparation of the implant site 2. placement of the implant LEONE 6.5 SHORT IMPLANT: 3. preparation of the implant site 4. placement of the implant TWO-STAGE SURGICAL PROCEDURE: 5. first stage 6. second stage CONDITIONING OF THE SOFT TISSUES: 7. for standard and large platform 8. for slim platform ONE-STAGE SURGICAL PROCEDURE: 9. for standard and large platform 11. two-stage surgical procedure for standard platform LEONE MAX STABILITY IMPLANTS Ø 3,75 AND Ø 4,5:...

Open the catalog to page 4
IMPLANTOLOGY - 5

INDIRECT TECHNIQUE: 5. final positioning for standard and large platform 90-91 6. final positioning for slim platform 91 DIRECT TECHNIQUE: 7. positioning and preparation of the abutment, impression taking for standard and large platform 92-93 OTHER PROSTHETIC SOLUTIONS: 8. ball head abutments for overdenture 93..97 9. bar-retained overdenture and screw-retained prosthesis 98..102 10. MultiTech abutments: directions for use 103-104 11. intraoral scanning and use of Ti-Base abutments (CAD-CAM solutions) 105 12. temporary abutments: application procedure 106..108...

Open the catalog to page 5
IMPLANTOLOGY - 6

Leone dental implant system LEONE DENTAL IMPLANT SYSTEM The LEONE implant system offers a wide range of products that allows to choose the most adequate solution for the planned rehabilitation depending on the clinical situation and the prosthetic requirements. The distinctive feature of the system is the LEONE implant-abutment connection, a combination of two geometries: self-locking Morse taper and internal hexagon. The Morse taper ensures a remarkable mechanical stability, total absence of micro movements, a perfect bacterial seal and optimal distribution of masticatory loading. The...

Open the catalog to page 6
IMPLANTOLOGY - 7

Leone implants LEONE IMPLANTS Made of medical grade 5 titanium, cylindrical screw shaped. HRS surface and LEONE connection. Mounted on a carrier, with an included biopolymer sealing cover cap, and packed in gamma-ray sterile glass vial. Cap removal from the inner holder and placement into the implant requires instrument Cat. 156-1003-00. Pack content: 1 implant and 1 cover cap LEONE IMPLANT Ø 4.1 mm with cover cap CARRIER IMPLANT INNER HOLDER LEONE IMPLANT Ø 4.8 mm with cover cap GLASS VIAL Ø 4,8 mm length

Open the catalog to page 7
IMPLANTOLOGY - 8

Leone 6.5 short implant LEONE 6.5 SHORT IMPLANT • Ideal for cases with limited vertical bone availability • To avoid complex bone grafting procedures • To minimize advanced surgical interventions (sinus lift, inferior alveolar nerve transposition) • To avoid sensitive anatomical structures with a high degree of safety • To increase patient’s acceptance due to reduced treatment time and costs LEONE 6.5 SHORT IMPLANT with cover cap Made of medical grade 5 titanium, cylindrical screw shaped. HRS surface and LEONE connection. Mounted on a carrier, with an included biopolymer sealing cover cap,...

Open the catalog to page 8
IMPLANTOLOGY - 9

Leone Max Stability implants LEONE MAX STABILITY IMPLANTS Max Stability implants feature an innovative external macro-design, formulated to obtain a high primary stability in cases where the implant site offers poor stability for fixtures with a classical design. The implant primary stability is evaluated by measuring the insertion torque values. In medium to poor bone quality they have over 50% higher insertion torque values compared to cylindrical implants with the same length and connection size. Max Stability implants 03,75 and 04,5 mm have the same internal connection as the 03,3...

Open the catalog to page 9
IMPLANTOLOGY - 10

platform switching and platforms of the Leone implant system PLATFORM SWITCHING The emergence profile of the LEONE abutments features a smaller diameter than the maximum diameter of the implant neck. The “Platform Switching” concept involves several advantages like the shift of the area of the inflammatory infiltrate inwards (away from the crestal bone), a reduced perimeter to protect against the external agents, a larger amount of periimplant gingival soft tissue and therefore a better mucosa seal to protect the crestal bone. THE MEANING OF PROSTHETIC PLATFORM After the placement of the...

Open the catalog to page 10
IMPLANTOLOGY - 11

standard platform SELF-LOCKING CAPS, LOW Made of medical grade 5 titanium. Single supplied on carrier and packed in gamma-ray sterilized glass vials. The caps are locked into the implant through the application of an impulsive force that activates the locking-taper connection. They are used in place of the cover caps in cases of subcrestal implant placement or in place of the healing caps in cases of low gingival thickness (pages 70, 71). Use the special hex head extractor Cat. 156-1006-00 to unlock the connection. Use the instrument for cover cap Cat. 156-1003-00 for removal. Pack of 1

Open the catalog to page 11