Multi-parameter ECG monitor K12
2Pages

{{requestButtons}}

Catalog excerpts

Multi-parameter ECG monitor K12 - 1

Technical Specifications ECG CO2 Input dynamic range: ±(0.5mVp—5mVp) Differential input impedance: >I0MQ 0.5~40Hz (Monitoring) 1~20Hz (Operation) CMRR: >90dB (Diagnostic) >I05dB (Monitoring & Operation) Sensitivity selection: x|/4, x|/2, xI, *2, x4 an d Auto HR accuracy: ±1% or ±2bpm, whichever is greate Pacemaker pulse detection and rejection function Technique: Sampling mode: Measuring range: Measuring accuracy: Infrared optical method Sidestream or Mainstream ±2mmHg ±5% of reading ±8% of reading ±I0% of reading Flow rate: Cerebral State Monitoring (CSM) RESP Measuring range: 0—I20rpm Measuring accuracy: ±5% or ±2 rpm, whichever is greater CSI and update: 0-I00. filter: 6-42Hz, I sec. update filter: 75-85 Hz, I sec. update. BS%: 0-I00. filter: 2-42 Hz, I sec. update TEMP Measuring range: 2I.0—50.0 C Measuring accuracy: ±0.2 Cfrom 25—45 C IBP NIBP Technique: Oscillometric method Typical measurement time : <30 seconds (adult cuff) NIBP measuring range : 40—200mmHg (Pediatric) NIBP measuring range: I0—I50mmHg (Pediatric) NIBP measuring range: 20—I65mmHg (Pediatric) 20—II0mmHg (Neonate) NIBP measuring accuracy: Mean difference: ±5mmHg NIBP measurement mode: Manual, Auto, STAT, Multi-cycle mode Auto measuring intervals: I-480min Technique: Strain gauge transducer Measuring accuracy: ±2% or ±4mmHg, whichever is greater ICP, AUXPI, AUXP2 Calibration: zero calibrating Blood temperature measuring: range: 23-43 C, accuracy: ±0.5 C Injecta temperature measuring: range: 0-20 C, accuracy: ±0.5 C Measuring range: 0.2—20 L/min Measuring accuracy: ±0.2 L/min or ±I0%, whichever is greater Other Specifications SpO2 Technique: Dual-wavelength optical method Measuring accuracy: Arms is not greater than 2% for SpO2 range 70—I00%. PR measuring range: 30—250bpm PR measuring accuracy: ±2bpm or ±2%, whichever is greater Built-in lithium battery: II.IV/4400mAh Display: I2.I inch TFT display Alarming method: 3 levels audible-visible alarm Networking: Ethernet Standard configuration ECG, Respiration, SpO2, PR, NIBP, Temperature 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, I2-lead ECG Cardiac Output, Cerebral State Monitoring, CMS, Touch Screen KI2Patient Monitor CREATIVE MEDICAL ce Shenzhen Creative Industry Co., Ltd. Floor 5, BLD 9, Baiwangxin High-Tech Industrial Park, Songbai Road, Xili Street Nanshan District, 5I8II0 Shenzhen, PEOPLE’S REPUBLIC OF CHINA Tel: +86 755 2643 35I4 Fax: +86 755 2643 0390 www.creative-sz.com info@creative-sz.com

Open the catalog to page 1
Multi-parameter ECG monitor K12 - 2

12.1” display with LED backlight 9-waveform on screen 360-degree visible indicator with 3-level alarm Patient Monitor Accessoy box for standard configuration Integral 3-channel thermal recorder Li-ion battery up to 4 hours continuous monitoring Parameter case for optional parameters Comprehensive calculations for clinical application 12.1” high resolution display Touch screen optional 9 traces on-screen waveforms and maximal up to 13 User customized NIBP measuring cycles up to 5-phase Data export and software upgrade Versatile clinical calculations for application convenience HL7 protocol,...

Open the catalog to page 2

All Lepu Medical Technology catalogs and technical brochures

  1. Lepgen-96

    1 Pages

  2. Nexor 96

    2 Pages

  3. Nexor 32

    2 Pages

  4. ELISA 200

    75 Pages

  5. Fluo-1800

    28 Pages