1. Catalogs
  2. Lepu Medical
  3. Multi-parameter ECG monitor K12

Multi-parameter ECG monitor K12
1 /2Pages

Multi-parameter ECG monitor K12

Multi-parameter ECG monitor K12
1 /2Pages

Catalog excerpts

Multi-parameter ECG monitor K12-1

Technical Specifications ECG CO2 Input dynamic range: ±(0.5mVp—5mVp) Differential input impedance: >I0MQ 0.5~40Hz (Monitoring) 1~20Hz (Operation) CMRR: >90dB (Diagnostic) >I05dB (Monitoring & Operation) Sensitivity selection: x|/4, x|/2, xI, *2, x4 an d Auto HR accuracy: ±1% or ±2bpm, whichever is greate Pacemaker pulse detection and rejection function Technique: Sampling mode: Measuring range: Measuring accuracy: Infrared optical method Sidestream or Mainstream ±2mmHg ±5% of reading ±8% of reading ±I0% of reading Flow rate: Cerebral State Monitoring (CSM) RESP Measuring range: 0—I20rpm Measuring accuracy: ±5% or ±2 rpm, whichever is greater CSI and update: 0-I00. filter: 6-42Hz, I sec. update filter: 75-85 Hz, I sec. update. BS%: 0-I00. filter: 2-42 Hz, I sec. update TEMP Measuring range: 2I.0—50.0 C Measuring accuracy: ±0.2 Cfrom 25—45 C IBP NIBP Technique: Oscillometric method Typical measurement time : <30 seconds (adult cuff) NIBP measuring range : 40—200mmHg (Pediatric) NIBP measuring range: I0—I50mmHg (Pediatric) NIBP measuring range: 20—I65mmHg (Pediatric) 20—II0mmHg (Neonate) NIBP measuring accuracy: Mean difference: ±5mmHg NIBP measurement mode: Manual, Auto, STAT, Multi-cycle mode Auto measuring intervals: I-480min Technique: Strain gauge transducer Measuring accuracy: ±2% or ±4mmHg, whichever is greater ICP, AUXPI, AUXP2 Calibration: zero calibrating Blood temperature measuring: range: 23-43 C, accuracy: ±0.5 C Injecta temperature measuring: range: 0-20 C, accuracy: ±0.5 C Measuring range: 0.2—20 L/min Measuring accuracy: ±0.2 L/min or ±I0%, whichever is greater Other Specifications SpO2 Technique: Dual-wavelength optical method Measuring accuracy: Arms is not greater than 2% for SpO2 range 70—I00%. PR measuring range: 30—250bpm PR measuring accuracy: ±2bpm or ±2%, whichever is greater Built-in lithium battery: II.IV/4400mAh Display: I2.I inch TFT display Alarming method: 3 levels audible-visible alarm Networking: Ethernet Standard configuration ECG, Respiration, SpO2, PR, NIBP, Temperature 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, I2-lead ECG Cardiac Output, Cerebral State Monitoring, CMS, Touch Screen KI2Patient Monitor CREATIVE MEDICAL ce Shenzhen Creative Industry Co., Ltd. Floor 5, BLD 9, Baiwangxin High-Tech Industrial Park, Songbai Road, Xili Street Nanshan District, 5I8II0 Shenzhen, PEOPLE’S REPUBLIC OF CHINA Tel: +86 755 2643 35I4 Fax: +86 755 2643 0390 www.creative-sz.com [email protected]

 Open the catalog to page 1
Multi-parameter ECG monitor K12-2

12.1” display with LED backlight 9-waveform on screen 360-degree visible indicator with 3-level alarm Patient Monitor Accessoy box for standard configuration Integral 3-channel thermal recorder Li-ion battery up to 4 hours continuous monitoring Parameter case for optional parameters Comprehensive calculations for clinical application 12.1” high resolution display Touch screen optional 9 traces on-screen waveforms and maximal up to 13 User customized NIBP measuring cycles up to 5-phase Data export and software upgrade Versatile clinical calculations for application convenience HL7 protocol, Bed...

 Open the catalog to page 2

All Lepu Medical catalogs and technical brochures

  1. Nexor 32

    2  Pages

  2. Fluo-1800

    28  Pages

  3. Lepgen-96

    1  Page

  4. Occluder Device

    20  Pages

  5. ELISA 200

    75  Pages

  6. Nexor 96

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.