1. Catalogs
  2. Lepu Medical
  3. Vesselin® Drug Coated Coronary Balloon Catheter

Vesselin® Drug Coated Coronary Balloon Catheter

Vesselin® Drug Coated Coronary Balloon Catheter

Vesselin® Drug Coated Coronary Balloon Catheter

Product catalog summary
Specifications
The document provides detailed specifications for a Drug Coated Coronary Balloon Catheter. The balloon material is PEBAX, with an effective length of 1350mm and a distal shaft outer diameter of 2.7F. The balloon crossing profile ranges from 0.026'' to 0.035'', and it is compatible with guiding catheters of 5F and above, as well as guide wires of 0.014''.
Balloon Compliance and Pressure
The balloon compliance is detailed with nominal and burst pressures. Expansion pressures are provided for various diameters, indicating the balloon's behavior under different atmospheric pressures.
Drug Coating and Release
The catheter is coated with Paclitaxel at a concentration of 3μg/mm², which inhibits restenosis. The drug release rate in vivo is over 90%, with effective concentration maintained for at least 28 days. The coating uses pharmaceutical-grade urea for better biocompatibility and effective drug release.
Design Features
The catheter features a spiral cut hypotube design for optimized deliverability and improved PEBAX material for enhanced flexibility and crossability. The particle size is maintained at 2-3μm to ensure long-term efficacy and low embolism risk.
Clinical Outcomes
Clinical data indicates no significant difference in late lumen loss, thrombosis, and target lesion failure (TLF) compared to control groups over 9 to 12 months. The document emphasizes balanced safety and effectiveness.
Procedures and Recommendations
Pre-dilatation with an ordinary balloon is recommended, with a balloon/artery diameter ratio of 0.8-1.0 and dilatation pressure greater than standard pressure. Angiographic results should show no dissection or only type A or B dissection, TIMI blood flow class III, and residual stenosis ≤ 30%. The catheter's distal and proximal parts should be 2-3mm longer than the pre-dilatation area, with dilatation applied at 7atm pressure for 30-60 seconds.
Contact Information
The document provides contact details for the manufacturer located in Beijing, China, including telephone, fax, and website information.
See more

Catalog excerpts

Vesselin® Drug Coated Coronary Balloon Catheter-1

DRUG COATED CORONARY BALLOON CATHETER Balloon compliance Nominal pressure Diameter /mm Burst Pressure No.37 Chaoqian Road, Changping District, Beijing 102200, P.R. China Tel:+86-10-80120666 Fax:+86-10-80120600 Website: https://en.lepumedical.com/ DRUG COATED CORONARY BALLOON CATHET

 Open the catalog to page 1
Vesselin® Drug Coated Coronary Balloon Catheter-2

DRUG COATED CORONARY BALLOON CATHETER BALLOON STRUCTURE FEATURES Drug Coating Coating with Active Pharmaceutical Ingredients grade urea, provide better biocompatibility, facilitate drug releasing effectively. Drug release rate in vivo achieves Safe and effective Drug dose, drug releasing keeps continuously and stably Paclitaxel concentration in blood vessel wall ng/mg 100 Paclitaxel loaded with drug dose at The effective drug concentration keeps at least 28 days, and inhibits Intimal hyperplasia in long term. Suitable particle size at 2-3μm, enables long term efficacy and low embolism risk Toxic...

 Open the catalog to page 2

All Lepu Medical catalogs and technical brochures

  1. Nexor 32

    2  Pages

  2. Fluo-1800

    28  Pages

  3. Lepgen-96

    1  Page

  4. Occluder Device

    20  Pages

  5. ELISA 200

    75  Pages

  6. Nexor 96

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.