1. Catalogs
  2. Lifescan
  3. one touch ultra

one touch ultra

one touch ultra
1 / 73 PagesView full catalog

one touch ultra

Product catalog summary
Important Safety Information
Ensure the OneTouch® Ultra® meter is functioning correctly by verifying the display, unit of measure (mg/dL), date, time, and code number match the test strip vial each time it is turned on. Incorrect settings can lead to misinterpretation of blood glucose results.
Introduction
The OneTouch® Ultra® System is a blood glucose monitoring system designed to help manage diabetes by providing accurate blood glucose readings. Maintaining blood glucose levels close to normal is crucial to reduce the risk of complications.
System Components
The system includes the OneTouch® Ultra® Blood Glucose Meter, Test Strips, Control Solution, and an Adjustable Blood Sampler, all designed to work together for accurate results.
Using the Meter
Before testing, ensure the meter is coded correctly to match the test strip vial. The meter displays results in mg/dL, the standard unit of measure in the United States.
Testing Procedure
Follow the step-by-step procedure for testing blood glucose levels, including preparing the blood sampler, obtaining a blood sample, and applying it to the test strip.
Important Test Strip Information
Store test strips in a cool, dry place and use them immediately after removal from the vial. Do not use expired or damaged test strips.
Warnings and Precautions
Severe dehydration, incorrect unit of measure, and improper coding can lead to inaccurate results. Always consult a healthcare professional if unexpected results occur.
Customer Support
LifeScan offers 24-hour customer service and online resources for additional support and information about diabetes care.
Specifications and Warnings
The OneTouch® Ultra® System is designed for blood glucose testing. Ensure the code numbers on the meter and test strip match. If 'mg/dL' does not appear with the symbol, contact LifeScan Customer Service.
Control Solution Testing
Control solution tests should be performed to practice the test process, when opening a new vial of test strips, weekly, if the meter or strips are suspected to be faulty, after unexpected results, or after dropping the meter. Use only OneTouch® Ultra® Control Solution and ensure it is at room temperature. Discard the first drop and wipe the tip before testing.
Blood Testing
Use the OneTouch® Ultra® Meter, test strips, lancing device, and sterile lancets. Never share lancets or the sampler. Wash hands and puncture site before testing.
Fingertip and Forearm Sampling
For fingertip sampling, use the OneTouch® UltraSoft® Cap. For forearm sampling, use the OneTouch® UltraClear® Cap. Forearm sampling may be less painful but may not reflect rapid changes in blood glucose levels.
Step-by-Step Test Procedure
1. Insert the test strip into the meter.
2. Apply a blood sample to the test strip.
3. Wait for the result, which appears in 5 seconds.
4. Dispose of used test strips and lancets properly.
Blood Glucose Testing and Alerts
If your blood glucose test result is above 600 mg/dL, the meter will display 'h1', indicating potential severe hyperglycemia. Recheck your blood glucose level, and if 'h1' appears again, contact your healthcare professional immediately.
Using the Meter Memory
The OneTouch® Ultra® Meter stores up to 150 test results with date and time, providing 14- and 30-day averages. Enter memory mode by pressing the button, and review averages and individual test results.
Downloading Test Results
To transfer data to a computer, use OneTouch® Diabetes Management Software and Interface Cable. Ensure the meter is off before connecting.
Comparing Meter and Laboratory Results
Meter results should generally agree with lab results within ±20%. Perform a control solution test before lab visits, fast for eight hours, and ensure tests are within 15 minutes of each other.
Meter Set-up
To set up the meter, start with it off and follow steps to set time, date, and unit of measure (mg/dL). Ensure settings are correct after battery replacement.
Caring for Your OneTouch® Ultra® System
Keep the meter clean and store it in its case. Clean the sampler with soap and water, and disinfect with a bleach solution.
Display Messages and Problem-Solving
The meter displays various messages to indicate status and errors. Ensure code numbers match between the meter and test strip vial for accurate results.
Specifications
Key specifications include a result range of 20 to 600 mg/dL, a sample size of 1 microliter, and a test time of 5 seconds. The device uses a glucose oxidase biosensor and is powered by a replaceable 3.0 V lithium battery.
Product Safety and Guarantee
The OneTouch® Ultra® system complies with UL 60601-1 standards and is guaranteed to be free from defects for three years from the date of purchase.
Additional Information
The document includes an index for quick reference to topics such as blood sampling, meter maintenance, and data downloading. It also provides target glucose ranges for people without diabetes.
See more

Catalog excerpts

one touch ultra-1

DCO_06405104B_OTU_Uni_OBC_US 3/8/06 12:48 PM Ultra Owner’s Booklet Page 2 Blood Glucose Monitoring System

 Open the catalog to page 1
one touch ultra-2

DCO_06405104B_OTU_Uni_OBC_US 3/8/06 12:48 PM Page 3 Important Safety Information To be sure your meter is working properly, EVERY time you turn it on confirm that: ◗ All segments are visible in the display check display check Example ◗ The unit of measure is correct (mg/dL) ◗ The date and time are correct unit of measure time date Example ◗ The code number on the meter display matches the code number on the test strip vial Example

 Open the catalog to page 2
one touch ultra-3

DCO_06405104B_OTU_Uni_OB_US 3/8/06 12:17 PM Page i OneTouch® Ultra® System Owner’s Booklet i

 Open the catalog to page 3
one touch ultra-4

DCO_06405104B_OTU_Uni_OB_US 3/8/06 12:17 PM Page ii Read this first Each time you turn on your meter, the unit of measure will appear on the display with the R symbol. The unit of measure will also appear under every test result. You may misunderstand your blood glucose results if your meter is set to the incorrect unit of measure. Your meter’s unit of measure should be set to mg/dL. If your meter is set to the correct unit of measure, “mg/dL” will appear on the display. Your test result will not include a decimal point (Fig. 1). Do Not change this setting – this is the correct unit of measure...

 Open the catalog to page 4
one touch ultra-5

DCO_06405104B_OTU_Uni_OB_US 3/8/06 12:17 PM Page iii If your meter is set to the other unit of measure, “mmol/L” will appear on the display. The test result will include a decimal point (Fig. 2). Unless your doctor has told you to use this unit of measure, Do Not test your blood glucose. Call LifeScan Customer Service at 1 800 227-8862 immediately for assistance. Fig. 2: mmol/L millimoles/liter decimal point Always confirm that the unit of measure is in mg/dL every time you test your blood glucose level. Use of the wrong unit of measure may cause you to misinterpret your blood glucose level,...

 Open the catalog to page 5
one touch ultra-6

DCO_06405104B_OTU_Uni_OB_US 3/8/06 12:17 PM Page iv Dear OneTouch® Ultra® System Owner: You have chosen one of the best blood glucose monitoring systems available. This booklet has important information you must know about the OneTouch® Ultra® System. Please read it carefully. Blood glucose monitoring plays an important role in diabetes control. A long-term study showed that keeping blood glucose levels close to normal can reduce the risk of diabetes complications by up to 60%.* The results you get with the OneTouch® Ultra® System can help you and your healthcare professional monitor and adjust...

 Open the catalog to page 6
one touch ultra-7

About Your New System vi Ultra* Blood Glucose Monitoring System 4 OneTouch® Ultra* Blood Glucose Meter 5 OneTouch® Ultra* Meter Display 6 OneTouch® Ultra* Test Strips 8 Checking the Meter Display 10 with Control Solution 13 Testing Your Blood 20 Preparing the OneTouch® UltraSoft* Adjustable Blood Sampler 21 Fingertip Blood Sampling 24 Forearm Blood Sampling 25 Step-by-Step Test Procedure 28 Discarding Used Test Strips and Lancets 31 Using the Meter Memory 34 Downloading Test Results to a Caring for Your OneTouch" Ultra* System 46 OneTouch® UltraSoft* Adjustable

 Open the catalog to page 7
one touch ultra-8

DCO_06405104B_OTU_Uni_OB_US 3/8/06 12:17 PM Page vi About Your New System The OneTouch® Ultra® System uses the latest blood glucose monitoring technology. It measures the glucose content of a blood sample by means of an electrical current produced in the test strip and measured by the meter. Test results are “plasma-calibrated.” This makes it easier for you and your diabetes-care team to compare your meter results with laboratory tests. If you have been using another type of meter–one that provides whole-blood results–you may notice that your test results with the OneTouch® Ultra® System are...

 Open the catalog to page 8
one touch ultra-9

DCO_06405104B_OTU_Uni_OB_US 3/8/06 12:17 PM Page 1 The OneTouch® Ultra® Blood Glucose Monitoring System consists of the OneTouch® Ultra® Blood Glucose Meter, OneTouch® Ultra® Test Strips (may be sold separately), and OneTouch® Ultra® Control Solution. These products have been designed, tested, and proven to work together to produce accurate blood glucose results. Use no other test strips or control solution other than OneTouch® Ultra® brand with your meter. CAUTION: If you cannot test due to a problem with your testing supplies, contact your healthcare professional or LifeScan Customer Service...

 Open the catalog to page 9
one touch ultra-10

DCO_06405104B_OTU_Uni_OB_US 3/8/06 12:17 PM Page 2 The OneTouch® Ultra® System is intended for use outside the body (in vitro diagnostic use). It should be used only for testing fresh capillary whole blood samples for glucose (sugar). It should not be used for the diagnosis of diabetes or for testing newborns. Before using any product to test your blood glucose, read all instructions and practice the test. Do all quality control checks as directed and consult with a diabetes healthcare professional. These recommendations apply to all blood glucose monitoring systems and are supported by the American...

 Open the catalog to page 10
one touch ultra-11

DCO_06405104B_OTU_Uni_OB_US 3/8/06 12:17 PM Page 3 Important Information ◗ Dehydration: Severe dehydration resulting from excessive water loss may cause false low results. If you believe you are suffering from severe dehydration, consult a healthcare professional immediately. ◗ Low glucose results: If your test result is lower than 70 mg/dL or is shown as LO, it may mean hypoglycemia (low blood glucose). This may require immediate treatment according to your healthcare professional's recommendations. Although this result could be due to a test error, it is safer to treat first, and then repeat...

 Open the catalog to page 11
one touch ultra-12

DCO_06405104B_OTU_Uni_OB_US 3/8/06 12:17 PM Page 4 The Complete OneTouch® Ultra® Blood Glucose Monitoring System OneTouch® Ultra® Meter OneTouch® UltraSoft ® Sterile Lancets Owner’s Booklet OneTouch® Ultra® Control Solution Quick Reference Guide OneTouch® Ultra® Test Strips (may be sold separately) OneTouch® UltraSoft ® Adjustable Blood Sampler ® Optional OneTouch UltraClear® Cap Carrying Case Warranty Registration Card Logbook 4

 Open the catalog to page 12

Archived catalogs

  1. SureStep®

    5  Pages

  2. one touch

    102  Pages

  3. SureStepFlexx

    117  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.