LiNA OperåScope™

Open the catalog to page 1
OperåScope™ - 2

LiNA OperåScope™ (Device) LiNA OperåScope™ for Hysteroscopy: The LiNA OperåScope™ is intended for use in visualization of the cervical canal and uterine cavity during diagnostic and therapeutic gynecological procedures. LiNA OperåScope™ for Cystoscopy: The LiNA OperåScope™ is intended for use in visualization of the female urethra and the bladder cavity during diagnostic and therapeutic cystoscopic procedures. PATIENT POPULATION: Adolescent or older patients with diagnostic and therapeutic gynecological procedures that require visualization of the cervical canal and uterine cavity. Video...

Open the catalog to page 2
OperåScope™ - 3

LiNA OperåScope™ LiNA OperåScope™ designed to be connected to the LiNA OperåScope™ HDMI cable. The LiNA OperåScope™ Recording Module is not intended to come in contact with the sterile field or the patient. The LiNA OperåScope™ and LiNA OperåScope™ Recording Module are to be used under ambient conditions and stored under room temperature and dry conditions. Environmental conditions during transportation and storage: Temperature 0°C to +55°C Air humidity 10% to 90% Atmospheric pressure 70 kPa to 106 kPa Environmental conditions during use: Temperature +10°C to +40°C Air humidity 35% to 75%...

Open the catalog to page 3
OperåScope™ - 4

LiNA OperåScope™ LiNA OperåScope™ o Hyponatremia, o Hypothermia, o Uterine perforation/false passage resulting in possible injury to bowel, bladder, major blood vessels and ureter, o Bladder perforation/false passage resulting in possible injury to bowel, uterus, major blood vessels and ureter, o Pulmonary edema, o Cerebral edema, o Infection, o Bleeding, o Pain, o Vasovagal episodes, o Urethral trauma (Cystoscopy specific). y The use of normal saline as a distending medium, and limiting the infused volume to less than 1000 ml is recommended to decrease the risk of the above complications....

Open the catalog to page 4
OperåScope™ - 5

LiNA OperåScope™ LiNA OperåScope™ the video/still imagery file, the downloaded file should be uploaded and saved to the patient’s medical record immediately post procedure ensuring the proper link between the file and the patient. Nominal input voltage: Nominal input frequency: Playback of recorded Video/Still images on computer Nominal input current: Nominal output voltage: Nominal output current Iout: Step 1 Insert the USB-stick into the computer USB port. Step 2 Download and install supplement codec software for Windows Media Player such as Media Player Codec Pack. Step 3 Click “Start”...

Open the catalog to page 5
OperåScope™ - 6

LiNA OperåScope™ LiNA OperåScope™ Warranty regarding further use of the Open Source Software LiNA Medical provides no warranty for the Open Source Software programs contained in this device, if such programs are used in any manner other than the program execution intended by LiNA Medical. The licenses listed below define the warranty, if any, from the authors or licensors of the Open Source Software. LiNA Medical specifically disclaims any warranties for defects caused by altering any Open Source Software program or the product´s configuration. You have no warranty claims against LiNA...

Open the catalog to page 6
OperåScope™ - 7

LiNA OperåScope™ LiNA OperåScope™ Además de LiNA OperåScope™, también tiene disponible LiNA OperåScope™ Recording Module (Figura 4) para capturar imágenes fijas y de vídeo, y poder visualizarlas posteriormente. LiNA OperåScope™ Recording Module no es estéril y está diseñado para conectarse al cable HDMI de LiNA OperåScope™. LiNA OperåScope™ Recording Module no está diseñado para entrar en contacto con el campo estéril ni con el paciente. LiNA OperåScope™ y LiNA OperåScope™ Recording Module deben utilizarse en condiciones ambientales, y almacenarse a temperatura ambiente y en condiciones...

Open the catalog to page 7
OperåScope™ - 8

LiNA OperåScope™ LiNA OperåScope™ y Si no se mantiene una irrigación continuada durante el funcionamiento de LiNA OperåScope™, la temperatura de funcionamiento de la punta distal puede superar los 41 oC (105,8 oF). y Mientras LiNA OperåScope™ Recording Module esté conectado a LiNA OperåScope™, asegúrese de que se pueda acceder fácilmente a la fuente de alimentación en caso de que sea necesario desconectar la alimentación. y Asegúrese de que LiNA OperåScope™ Recording Module y el monitor están fuera del alcance del paciente. y Posibles complicaciones de la histeroscopia/cistoscopia de flujo...

Open the catalog to page 8
OperåScope™ - 9

LiNA OperåScope™ LiNA OperåScope™ LiNA OPERÅSCOPE™ RECORDING MODULE La fuente de alimentación de LiNA OperåScope™ Recording Module se prepara conforme al punto 4 incluido anteriormente en estas instrucciones de uso. El número de referencia en EE. UU. de LiNA OperåScope™ Recording Module es OP-RM-1 y utiliza una toma de corriente de tipo A. Descarga de vídeo/archivos de imágenes estáticas postprocedimiento Los vídeos y las imágenes estáticas se pueden descargar de LiNA OperåScope™ mediante la toma USB de LiNA OperåScope™ Recording Module e importar en el historial médico del paciente. Como...

Open the catalog to page 9
OperåScope™ - 10

El cumplimiento de estas condiciones de licencia le dará derecho a utilizar el software de código abierto según lo previsto en la licencia correspondiente. En caso de conflicto entre las condiciones de la licencia de LiNA Medical y las condiciones de la licencia del software de código abierto, prevalecerán las condiciones del software de código abierto con respecto a las partes del software de código abierto. El software de código abierto está libre de derechos (es decir, no se cobra ninguna tarifa por el ejercicio de los derechos de licencia, mientras que pueden cobrarse tarifas por el...

Open the catalog to page 10