Product Overview
The document describes the REDLINE® Points of Use W 40, a wall-mounted system designed for specialty gases requiring high purity, tightness, and safety. It is available in various designs (A, B, C, F) and materials (brass, stainless steel).

Design Specifications
  • Design A: Basic model with no specified pressure or flow range.
  • Design B: Offers pressure ranges of 0.1–1 bar (1.5–15 psi), 0.5–6 bar (8–85 psi), and 1–10.5 bar (15–150 psi).
  • Design C: Similar to Design B with additional equipment.
  • Design F: Fixed pressure and flow meter with a pressure of 3 bar (45 psi).


Technical Data
  • Maximum primary pressure: 40 bar (550 psi).
  • Pressure gauge scales: Ranges from -1 to 18 bar (-14.5 to 260 psi).
  • Maximum flow rates for nitrogen: 2 Nm3/h (700 SCFH), 6 Nm3/h (2,100 SCFH), 11 Nm3/h (3,850 SCFH).
  • Materials: Brass (Ni/Cr plated) and Stainless Steel 316L.
  • Operating temperature: -20 to +70°C (-4 to +158°F).


Contact Information
Linde AG, Linde Gases Division, Seitnerstrasse 70, D-82049 Pullach, Germany. Phone: +49.89.74 46 1661, Fax: +49.89.74 46-2071, Email: [email protected], Website: hiq.linde-gas.com.
See more

Catalog excerpts

REDLINE® Points of use W 40.-1

3 Product sheet, Specialty gas W 40, design C. Description The point of use is especially developed for specialty gases with high demands of purity, tightness and safety. The point of use is intended for wall-mounting with external gas supply line. Design F is a version with fixed pressure and flow meter. Product name W 40 A, brass W 40 A, stainless steel W 40 B, brass W 40 B, brass W 40 B, brass W 40 B, stainless steel W 40 B, stainless steel W 40 B, stainless steel W 40 C, brass W 40 C, brass W 40 C, brass W 40 C, stainless steel W 40 C, stainless steel W 40 C, stainless steel W 40 F, brass W 40 F, stainless steel ® HiQ and REDLINE are registered trademarks of The Linde Group.

 Open the catalog to page 1
REDLINE® Points of use W 40.-2

3 REDLINE® Points of use W 40. Wall design. 2 of 2 3 REDLINE® Points of use W 40. Wall design. 2 of 2 Technical data Pressure gauge scale -1-1.5 bar -14.5-21 psi Max flow (nitrogen) 2 Nm3/h 700 SCFH Material Brass, Ni/Cr plated All measurements in millimeters. W40 C in the drawing is extra equipped. Linde AG Linde Gases Division, Seitnerstrasse 70, D-82049 Pullach, Germany Phone +49.89.74 46 1661, Fax +49.89.74 46-2071, e-mail: [email protected], http://hiq.linde-gas.com.

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.