Lindner Logic-OT / Life-OT - 1

Data sheet Partition system Lindner Logic-OT / Life-OT Klinikum Großhadern BrainSuite King Faisal Specialist Hospital Riyadh Partition system type Lindner Logic-OT Metal Partition system type Lindner Life-OT Backlight The partition systems Logic OT and Life OT are special designs for operating theatre installations. The partition panels can be made from various materials such as stainless steel or HPL. One of the system’s highlights is the integrated room-high Life-OT glazing, which can be made of coloured glass and optionally be provided with additional LED backlighting. All surfaces, joints and connections to adjoining parts are designed to make cleaning and disinfection as easy as possible. For more information, visit our website www.Lindner-Group.com Lindner Reinraumtechnik GmbH, Bahnhofstraße 23, 94424 Arnstorf / Germany, Tel. +49 (0)8723/20-0, Fax +49 (0)8723/20-23 55 Reinraumtechnik@Lindner-Group.com, www.Lindner-Group.com Subject to change without notice. This document is our intellectual property. It may neither be copied, nor used by unauthorized parties, nor professionally distributed or submitted to other people witho ut our approval.

Open the catalog to page 1
Lindner Logic-OT / Life-OT - 2

Data sheet Partition system Lindner Logic-OT / Life-OTSystem description Substructure The substructure consists of galvanized or coated folded steel profiles. • Lindner Logic-OT Metal Metal shell: 13 or 19 mm o Powder coating acc. to RAL or NCS colour range o Coil-Coating (duplex), colour 9010 acc. to Lindner o Stainless steel ground and polished • Lindner Logic-OT HPL GF-Board Gypsum fibre plate with both-sided applied HPL (thickness approx. 19 mm) • Lindner Logic-OT HPL CF-Board Cement carrier plate with both-sided applied HPL (thickness approx. 12 mm) • Lindner Logic-OT HPL...

Open the catalog to page 2
Lindner Logic-OT / Life-OT - 3

Data sheet Partition system Lindner Logic-OT / Life-OT Radiation protection Depending on the requirements, this partition system can be equipped to meet a lead equivalent value of 0,2 to 0,4. As an option, the lead equivalent value can be improved by taking specific measures. Customized solutions based on the requirements of the project available upon request. Applicable standards DIN 18202 tolerances in building construction – branches of building industry For more information, visit our website www.Lindner-Group.com Lindner Reinraumtechnik GmbH, Bahnhofstraße 23, 94424 Arnstorf / Germany,...

Open the catalog to page 3

All Lindner Group catalogs and technical brochures

  1. decke_br_lunar

    12 Pages

  2. mkt_br_stadia

    20 Pages

  3. wand_br_life

    44 Pages

  4. bt_br_tunnel

    8 Pages

  5. Clean Rooms

    20 Pages

  6. Doors

    20 Pages