1. Catalogs
  2. LivaNova
  3. MEMO 3D RECHORD TM
video corpo

MEMO 3D RECHORD TM

MEMO 3D RECHORD TM
1 / 20 PagesView full catalog

MEMO 3D RECHORD TM

Product catalog summary
Introduction
LivaNova, a leader in cardiac surgery solutions, has developed the Memo 3D ReChordTM, an innovative device for mitral valve repair. This device aims to improve patient outcomes and simplify surgical procedures through advanced technology.

Product Overview
The Memo 3D ReChordTM is designed to assist surgeons in mitral valve repair by providing a flexible, semi-rigid annuloplasty ring. It features a superelastic alloy core that maintains its shape and supports the natural motion of the mitral annulus. The device is coated with CarbofilmTM to enhance biocompatibility and prevent inflammation.

Design and Features
The Memo 3D ReChordTM incorporates a unique chordal guiding system that facilitates artificial chordae replacement, making it a routine procedure. The ring's design allows for physiological three-dimensional motion, preserving the natural saddle shape of the mitral annulus. It also includes a silicone sheath for easy suturing and a new holder for improved implantation.

Performance and Benefits
The device maximizes hemodynamics and reduces stress on the mitral valve by supporting systolic remodeling and diastolic dynamics. Clinical data suggests that the Memo 3D ReChordTM provides consistent and reproducible results, with a focus on maintaining physiological dynamics over time.

Implantation Procedure
The Memo 3D ReChordTM is designed for ease of use, with features that enhance visualization and placement during surgery. The implantation process is streamlined with a new holder and sizers, facilitating minimally invasive procedures.

Clinical Highlights
Initial clinical experiences indicate that the Memo 3D ReChordTM simplifies the implantation of PTFE neochordae, reducing operative times and standardizing the mitral valve repair technique.

Ordering Information
The document provides detailed ordering information for the Memo 3D ReChordTM and its accessories, including various sizes and instrument sets.

Conclusion
The Memo 3D ReChordTM represents a significant advancement in mitral valve repair technology, offering surgeons a reliable and innovative solution to improve surgical outcomes.
See more

Catalog excerpts

MEMO 3D RECHORD TM-1

LivaNova Health innovation that matters MEMO 3D RECHORD™ Ready to repair

 Open the catalog to page 1
MEMO 3D RECHORD TM-2

CARDIAC SURGERY SOLUTIONS A 45-year long history of innovative records in cardiac surgery LivaNova’s relentless commitment to providing innovative solutions through advanced technologies and breakthrough therapeutic treatments for cardiovascular diseases is an innate trait of its DNA and has brought the company to become world leader in the field of cardiac surgery. Solo Smart Carbofilm Bicarbon

 Open the catalog to page 2
MEMO 3D RECHORD TM-3

LivaNova offers a portfolio of solutions to all types of mitral valve disease Its latest innovation is Memo 3D ReChordTM, the ultimate repair device designed to deliver better patient outcomes while facilitating the surgical procedure. Memo 3D ReChordTM is every surgeon’s invaluable partner, its innovative chordal guiding system makes artificial chordae replacement a routine procedure1. 1. Glauber et al., Ann Cardiothorac Surg. 2015;4 (3):298-300

 Open the catalog to page 3
MEMO 3D RECHORD TM-4

MITRAL SOLUTIONS Mitral valve repair is now the most frequently performed surgical procedure for mitral valve disease…but repair and replacement may be applied to different subsets of patients. (Daneshmand et al., Ann Thorac Surg 2009;88:1828–37) Each patient requires a tailored care, and every surgeon needs in his hands the best solution to meet this expectation. Therefore to address the surgical need to have the best solution fitting each patient and surgeon requirements, only a truly and integrated offering can respond. LivaNova Mitral Solutions offers a full range of devices for each and...

 Open the catalog to page 4
MEMO 3D RECHORD TM-5

Sovering Band Sovering Tricuspid Band Sovering Mini Band Carbomedics Annuloflex Carbomedics Annuloflo Bicarbon Fitline Carbomedics Optiform Carbomedics Standard Pediatric Pericarbon More

 Open the catalog to page 5
MEMO 3D RECHORD TM-6

Innovation rings true

 Open the catalog to page 6
MEMO 3D RECHORD TM-7

Introducing MEMO 3D LivaNova Memo 3D annuloplasty ring has been engineered with the aim to create a unique and optimal solution across the entire spectrum of mitral valve repair. The unique core of Memo 3D provides a firm support to the mitral annulus while allowing the natural physiological 3D motion that truly reflects the native mitral annulus. The innovative design of Memo 3D provides reproducible results, predictable outcomes, and superior performance combined with enhanced hemo and biocompatibility.

 Open the catalog to page 7
MEMO 3D RECHORD TM-8

DESIGN Unique to its core

 Open the catalog to page 8
MEMO 3D RECHORD TM-9

Unique super-elastic alloy core The exclusive alloy core cell design is a laser-cut one-piece structure that allows truly physiological annular dynamics. The precision laser-cutting technology is also used to obtain LivaNova’s innovative Perceval sutureless aortic prosthesis. Shape Memory The superelastic alloy core “remembers” a prefixed shape after geometric deformation and can be flexed back and forth without losing its original form. Memo 3D’s shape memory provides consistent recovery of the systolic profile and restores the natural systolic diameter ratio. The Right Balance of Rigidity and...

 Open the catalog to page 9
MEMO 3D RECHORD TM-10

PERFORMANCE The true reflection of the mitral annulus

 Open the catalog to page 10
MEMO 3D RECHORD TM-11

Systolic remodeling and diastolic dynamics concept Truly physiological three-dimensional motion of the mitral annulus with a natural anterior/posterior to lateral/lateral relationship to maximize blood flow,2,3,4 even after more than five years from implantation.5 Systolic Remodelling Diastolic Dynamics Maximized Hemodynamics Maximized Coaptation and Reduced Stress Ryomoto et al. Ann Thorac Surg. 2014 Feb;97(2):492-7 Physiologic saddle shaping concept The true physiological 3D motion of the ring during the cardiac cycle preserves the natural non-planar saddle shape geometry of the annulus. Recent...

 Open the catalog to page 11
MEMO 3D RECHORD TM-12

IMPLANTATION Ease of use and implant

 Open the catalog to page 12
MEMO 3D RECHORD TM-13

PERFECT ANNULAR FIT AND VISUALIZATION: Silicone ring for easy needle penetration and white sutures as guidelines The Memo 3D semirigid annuloplasty ring facilitates easier implantation with superior visualization, placement, and attachment. The oval cross section of the silicone sheath provides more material for easier needle penetration. White suture guidelines on the underside of Memo 3D provide an excellent visual reference point for easier suturing. Oval silicone crosssection for easy needle penetration White suture guideline to aid suture placement New holder The new, versatile holder has...

 Open the catalog to page 13
MEMO 3D RECHORD TM-14

INNOVATION Guiding Standards MEMO 3D ReChordTM is the ultimate Repair device technology designed to deliver better patient outcomes while facilitating the surgical procedure, thanks to its innovative chordal guiding system that makes artificial chordae replacement a routine procedure. MEMO 3D ReChordTM incorporates a series of loops in the posterior region that act as temporary reference elements for easier sizing of chords length. The innovative chordal guiding system promotes standardized chord replacement, offering reproducible results while accelerating procedure times.1 Facilitating and...

 Open the catalog to page 14
MEMO 3D RECHORD TM-15

Mitral regurgitation: Annuloplasty ring sizing chordal rupture 4 Chord should be passed through the window Anchoring of the artificial chord Cut at the P2 area and remove the holder Ring parachuting and implantation

 Open the catalog to page 15
MEMO 3D RECHORD TM-16

Artificial chord through the reference element on the Memo 3D Rechord Knots are tied at the annular level Step 1: pull the blue thread first Step 2: then pull the yellow thread Fast, reproducible procedures for durable patient outcomes Truly physiological 3D motion of the mitral annulus

 Open the catalog to page 16
MEMO 3D RECHORD TM-17

New holder One-step removal Remove all with one single cut: fast removal, user friendly (one cut only at the P2 area). Two-step removal For those that prefer to have a rigid frame when tying the knots (avoid purse string effect and stress on the structure) and to protect the loops from the knotpusher when addressing the valve in MICS. Specifically designed handle for an easy removal of the LOW PROFILE TEMPLATE with forceps. Cut at the P2 area and remove the template with forceps

 Open the catalog to page 17
MEMO 3D RECHORD TM-18

Clinical highlights from the first published experience The length of the neochordae obtained will exactly match the plane of the native annulus at the coaptation point. This is a simple and reproducible technique, suitable for both anterior and posterior leaflet prolapse, which restores leaflet motion and ensures a large surface of coaptation. According to our experience, the temporary chordal guide system allows a correct implantation of PTFE neochordae without the need for chordal measurement, short operative times and doesn't require a long learning process. In our opinion, its use might...

 Open the catalog to page 18
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.