
Catalog excerpts

GMP RF TH F Real Time Wireless Temperature and Humidity Data Logger with Flexible Sensor 0% to 100% RH non condensing -40°C to +100°C + + + + + Sensor type - flexible - customized - Sensor size - cross section Operating Range - body - Sensor Accuracy Resolution Memory capacity Memory type Sampling rate Transmission Internal clock drift Mechanical - material - enclosure - weight - diameter - height Power Battery lifetime Antenna Wireless range Radio frequency Access point Calibrations Certification Collects and transmits real time humidity and temperature to XpertLog Software ITS-90 calibration coefficients are stored in the internal memory Complies with FDA 21 CFR Part 11 Network ready: multiple users, centralized, server database, active directory authentication Can be remotely activated Hum: capacitive / Temp: 4 wires PT-100 430 mm (17”) up to 5000 mm (195”) 1.5 x 8 mm (0.06 x 0.315”) 1.77 mm² (0.0027 inch²) 0% to 100% RH non condensing -40°C to +100°C -200°C to +200°C ±2.0% RH, 0% to 75% non condensing at 20°C to 45°C ±3.0% RH, 75% to 100% non condensing at 20°C to 45°C ±0.1°C from -40°C to +100°C 0.01% RH; 0.01°C 16,000 data points humidity / 16,000 data points temperature non volatile 1 sec to 24 hours simultaneous: maximum 20 loggers sequential: unlimited 4 sec / 24 h @ 23°C Peek 1000 - FDA compliant IP-51 95 g (3.35 oz) 65 mm (2.56”) 62 mm (2.44”) 2 x Lithium batteries, 0.35 g/each Lithium content classified UN3091 under IATA DGR section 3.9.2.6 compliant with ICAO/IATA packing instructions 970, user replaceable Up to 6 months, based on usage Internal 121 m (400 feet) 2.4 Ghz ISM band USB to computer Programs and reads unlimited number of loggers Factory Calibrations: traceable NIST/COFRAC - ITS-90 coefficients stored in the internal memory User Calibrations: closed loop calibration using XpertLog® software Health Safety: EN 60950-1 / 2006 EMC: EN 60601-1-2 / 2007 RF: EN 300440-2 v1.3.1 (2009-03) Visit www.lives-international.com for more details. Order Reference GMP-RF-TH-F Standard Calibration Points • 25°C / 20% RH • 25°C / 45% RH • 30°C / 65% RH • 40°C / 75% RH Upon special request:
Open the catalog to page 1All Lives International catalogs and technical brochures
-
Standard Data Logger GMP
1 Pages
-
Access Point LAN
1 Pages
-
Access Point
1 Pages
-
GMP Custom RF
1 Pages
-
GMP RF Bio
1 Pages
-
GMP RF TP F
1 Pages
-
GMP RF F MTR
1 Pages
-
GMP RF TCO2 F
1 Pages
-
GMP RF TP
1 Pages
-
GMP RF F 10RA THIN
1 Pages
-
GMP RF F 10RA
1 Pages
-
GMP RF F 10R THIN
1 Pages
-
GMP RF F 10R
1 Pages
-
GMP RF F 20R8V
1 Pages
-
GMP RF F 2R22V
1 Pages
-
GMP RF F 2R4V
1 Pages
-
GMP RF 5F HT
1 Pages
-
GMP RF 5F
1 Pages
-
Accessories
2 Pages
-
X p e r t L o g® Software
1 Pages
-
XperTrack
1 Pages
-
GMP RF F LP
1 Pages
-
GMP RF F
1 Pages