GMP RF TH F-1

GMP RF TH F Real Time Wireless Temperature and Humidity Data Logger with Flexible Sensor 0% to 100% RH non condensing -40°C to +100°C + + + + + Sensor type - flexible - customized - Sensor size - cross section Operating Range - body - Sensor Accuracy Resolution Memory capacity Memory type Sampling rate Transmission Internal clock drift Mechanical - material - enclosure - weight - diameter - height Power Battery lifetime Antenna Wireless range Radio frequency Access point Calibrations Certification Collects and transmits real time humidity and temperature to XpertLog Software ITS-90 calibration coefficients are stored in the internal memory Complies with FDA 21 CFR Part 11 Network ready: multiple users, centralized, server database, active directory authentication Can be remotely activated Hum: capacitive / Temp: 4 wires PT-100 430 mm (17”) up to 5000 mm (195”) 1.5 x 8 mm (0.06 x 0.315”) 1.77 mm² (0.0027 inch²) 0% to 100% RH non condensing -40°C to +100°C -200°C to +200°C ±2.0% RH, 0% to 75% non condensing at 20°C to 45°C ±3.0% RH, 75% to 100% non condensing at 20°C to 45°C ±0.1°C from -40°C to +100°C 0.01% RH; 0.01°C 16,000 data points humidity / 16,000 data points temperature non volatile 1 sec to 24 hours simultaneous: maximum 20 loggers sequential: unlimited 4 sec / 24 h @ 23°C Peek 1000 - FDA compliant IP-51 95 g (3.35 oz) 65 mm (2.56”) 62 mm (2.44”) 2 x Lithium batteries, 0.35 g/each Lithium content classified UN3091 under IATA DGR section 3.9.2.6 compliant with ICAO/IATA packing instructions 970, user replaceable Up to 6 months, based on usage Internal 121 m (400 feet) 2.4 Ghz ISM band USB to computer Programs and reads unlimited number of loggers Factory Calibrations: traceable NIST/COFRAC - ITS-90 coefficients stored in the internal memory User Calibrations: closed loop calibration using XpertLog® software Health Safety: EN 60950-1 / 2006 EMC: EN 60601-1-2 / 2007 RF: EN 300440-2 v1.3.1 (2009-03) Visit www.lives-international.com for more details. Order Reference GMP-RF-TH-F Standard Calibration Points • 25°C / 20% RH • 25°C / 45% RH • 30°C / 65% RH • 40°C / 75% RH Upon special request:

 Open the catalog to page 1

All Lives International catalogs and technical brochures

  1. Access Point

    1  Page

  2. GMP RF Bio

    1  Page

  3. GMP RF TP F

    1  Page

  4. GMP RF F MTR

    1  Page

  5. GMP RF TP

    1  Page

  6. GMP RF F 10R

    1  Page

  7. GMP RF 5F HT

    1  Page

  8. GMP RF 5F

    1  Page

  9. Accessories

    2  Pages

  10. XperTrack

    1  Page

  11. GMP RF F LP

    1  Page

  12. GMP RF F

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.