Intensive care ventilation
40Pages

{{requestButtons}}

Catalog excerpts

Intensive care ventilation - 1

Backup Dynamic BiLevel OFF 10. Vt **00)

Open the catalog to page 1
Intensive care ventilation - 2

Intensive care ventilation. Simple, effective and lung protective.

Open the catalog to page 2
Intensive care ventilation - 3

elisa 300 elisa 500 elisa 600 elisa 600 elisa 800 elisa 800VIT Contents The elisa code - 4 agile system design for individualised ventilation therapy elisa - 6 because intensive care ventilation depends on individual factors elisa 300 | 500 The new compact class in intensive care ventilation 8 with the latest turbine technology Instant View Technology 10 in control at all times Easy Access Bar 12 precise operation even in stressful situations A clean affair 14 a simple way to prevent nosocomial pneumonia PEEPfinder 16 gold standard bedside lung diagnostics Volatile sedation meets intensive...

Open the catalog to page 3
Intensive care ventilation - 4

In theory, things couldn't be simpler - air has to go in and out. Clinical practice, in contrast, consists of a wide range of requirements for modes, setting parameters, diagnostic options, and therapeutic manoeuvres. As a result, ventilators quickly become overly complex, subject to compromise or require intensive training. The agile system architecture of the elisa family easily accommodates hospital standards while reducing operator errors and training expenses. Whether customised rounds views, resuscitation mode or automatic spontaneous breathing trial - the user interface can be...

Open the catalog to page 4
Intensive care ventilation - 6

because intensive care ventilation depends on individual factors elisa 600 | 800 | 800VIT The premium range in intensive care ventilation

Open the catalog to page 6
Intensive care ventilation - 7

The platform concept enables situation-based configuration. The flexible system architecture is adaptable for future requirements and accommodates medical and technical developments. It offers a full range of diagnostic and therapeutic tools for personalized, intuitive ventilation – from common clinical standards to our ventilator-integrated impedance tomography (VIT), which continues to be unparalleled worldwide.

Open the catalog to page 7
Intensive care ventilation - 8

elisa 300 | elisa 500 The new compact range in intensive care ventilation with the latest turbine technology elisa 300 combines the benefits of the compact class with the features of a state-of-the-art universal ventilator. The devices support a full range of invasive and non-invasive ventilation therapy methods as well as high-flow O2. The innovative user interface and the comprehensive device configuration options are the basis for versatile application options in intensive care, intermediate care, emergency rooms or during intra-hospital transfer. The 12.1-inch display with a stunning...

Open the catalog to page 8
Intensive care ventilation - 9

The compact-class device elisa 500 features top-shelf performance characteristics, while offering a full therapeutic range of clinical ventilation options in turbine-driven devices. The innovative user interface of the elisa family, along with extensive configuration options and a stunning colour performance of the 15-inch display, create the basis for a wide range of applications from the weaning unit to maximum care in the ICU. As a modern universal ventilator for invasive and non-invasive applications, even the basic version of elisa 500 features special sensors, transpulmonary pressure...

Open the catalog to page 9
Intensive care ventilation - 11

Don’t miss the wood for the trees – instantly assess the current ventilation situation and identify developing problems. Time is a scarce resource in everyday clinical practice. Increasing workloads, critical situations as well as normal routine place high demands on medical personnel. The cumbersome operation of complicated devices causes additional stress and creates sources of error. That calls for innovative technology which offers a clear overview of the required information in a structured format. Simply smart! Instant View Technology The Instant View Technology gives you an intuitive...

Open the catalog to page 11
Intensive care ventilation - 12

Easy Access Bar precise operation even in stressful situations New answers are needed for intelligent operation – the Easy Access Bar enables fast response.

Open the catalog to page 12
Intensive care ventilation - 13

Easy Access Bar The Easy Access Bar of the intensive care ventilator family elisa The absence of conventional rotary 300 to elisa 800VIT lets you choose the required settings with knobs makes operation easy and verifi- precision and ease, even in stressful situations. The touch- able. The fully disinfectable surface screen operation provides intuitively understandable, unmis- enables hygienic operation at minimal takable feedback on the selected setting. Since all numerical values and setting parameters are consistently arranged in the same location, operating the devices becomes an easy...

Open the catalog to page 13
Intensive care ventilation - 15

A clean affair a simple way to prevent nosocomial pneumonia The device's numerous individual functions and architecture support compliance with suitable infection prevention measures. Pneumonia is the most common nosocomial infection occur- The configurable hygiene function sup- ring in ventilation patients. It leads to extended hospital stays ports the implementation of internal hospital hygiene standards without the need for complex RFID technology or The elisa series features a number of functions to support the the purchase of expensive special necessary measures for reducing nosocomial...

Open the catalog to page 15
Intensive care ventilation - 16

PEEPfinder gold standard bedside lung diagnostics The PEEPfinder makes the determination of the optimal PEEP range as easy as setting the respiratory rate. It is considered an established fact that mine the elastic properties of the lungs. A number of evalua- the cyclic collapse and reopening of tion options are available for this purpose. Graphic evaluation lung areas in patients with ALI signifi- support for detecting inflection points, stress indices, and stor- cantly damages the pulmonary tissue age of up to 10 reference loops facilitate the straightforward and that alveolar cycling of...

Open the catalog to page 16
Intensive care ventilation - 17

The next PEEPfinder cannot be started before the expiry of the 60-iccond lockout time after the last manoeuvre. Insp. Hold Exp. Hold Manual Breath Sigh Recruitment

Open the catalog to page 17
Intensive care ventilation - 19

Volatile sedation meets intensive care ventilation optimised ventilation with bespoke sedation The use of volatile anaesthetics enables daily awakening trials, timely neurological assessment, and avoiding benzodiazepine hangover. Daily awakening trials, propofol infusion tending the mean expiration time, reduces the risk of trapping, syndrome, timely neurological assess- and guarantees the accuracy of volume measurement. ment of ventilated, intensive care patients or reducing brief reactive psycho- In combination with the Leolyzer multi-gas sensor, elisa de- vices can directly measure and...

Open the catalog to page 19