video corpo

Array LaserLink
6Pages

{{requestButtons}}

Catalog excerpts

Array LaserLink - 1

Array LaserLink Pattern Scanning Laser Technology Enhancing Life. Advancing Technology.

Open the catalog to page 1
Array LaserLink - 2

Array LaserLink Pattern Scanning Laser Technology Pattern Scanning Laser can reduce photocoagulation treatment time by as much as 60% Pattern scanning laser provides enhanced uniformity of laser application, shorter treatment time, and less discomfort to the patient. The Array LaserLink offers pattern scanning capabilities compatible with Lumenis laser systems and popular slit lamps, versatility of wavelengths, various adjustable patterns and a range of laser spot sizes. Links with Lumenis lasers: With Lumenis multi-wavelength technology, Array delivers any of the following wavelengths: •...

Open the catalog to page 2
Array LaserLink - 3

Array LaserLink Eyes Forward Control Keeps the Target in View Maintain focus on the patient Eyes Forward Control Is afforded by the ability to control and verify treatment parameters without moving from the slit lamp oculars or losing sight of the target retina. Unique Array Touchpad • Uses just the simple stroke of a finger • Is movable for left or right hand use • Adjusts laser parameters and micromanipulation Heads Up Display • Confirms changes to treatment parameters • Shows text on the retina • Modified parameters are projected as text onto the retina Intuitive Touchscreen • On a fully...

Open the catalog to page 3
Array LaserLink - 4

Customize treatment to meet the needs of the patient and physician Continuously Variable Spot Size • Single spot from 50µm to 1000µm • Pattern mode from 100µm to 500µm • For customized treatment for the particular disease state and tissue response Variety of Adjustable Patterns • Includes single spot and 6 shapes • Square: 2 to 5 spots per side • Line: 2 spots in one line up to 4 spots in each of 5 lines • Triangle: 6 or 15 spots • Circle: Single adjustable ring • Half and quarter circle: 1 or 3 adjustable rings Up to 5 Preset Protocols • Retain favorite settings in memory • Include...

Open the catalog to page 4
Array LaserLink - 5

With unique Eyes Forward Control the physician does not lose sight of the patient’s retina. Touchpad The Array Touchpad allows adjustment to laser power, pattern, number of spots, spacing between spots, rotation of pattern and micromanipulation of the aiming and laser beam - all with just the stroke of a finger. Heads Up Display Heads Up Display shows changes to pattern spot parameters as text on the retina, seen through the oculars of the slit lamp. 110 mW Touchscreen Intuitive Touchscreen duplicates the functions of the laser’s remote control. The fully adjustable monitor is locatable on...

Open the catalog to page 5
Array LaserLink - 6

Lumenis Array LaserLink Specifications Patterns Single spot, square, line, triangle, circle, half circle, quarter circle Spot Size Spot Spacing Spot Duration Compatible lasers Vision One Novus Spectra / Spectra DP Compatible slit lamps Off Axis Illumination Slit Lamps Lumenis 980 | Zeiss 30SL | Zeiss SL130 On Axis Illumination Slit Lamps* Lumenis 990 | Haag Streit 900BQ Electrical requirements General specifications Weight Console: 3.5 kg | Array LaserLink Module: 5 kg Equipment classification *May have later release date Lumenis® Certified Service | Certified Engineers & Parts > Reliable...

Open the catalog to page 6

All Lumenis catalogs and technical brochures

  1. ResurFX™

    4 Pages

  2. SlimME™

    2 Pages

  3. UltraPulse®

    6 Pages

  4. ResurFX

    2 Pages

  5. LumeProbe

    4 Pages

  6. InSight

    8 Pages

  7. M22

    6 Pages

  8. AcuPulse

    8 Pages

  9. Selecta

    12 Pages

  10. Novus Varia

    8 Pages

  11. Aura PT

    4 Pages

  12. Vision One

    8 Pages