

Catalog excerpts

Lumenis SLT The Preferred Choice of Leading Ophthalmic Institutions in the USA Q-Switched Nd:YAG Q-Switched, frequency doubled Nd:YAG 0.3 - 2.0 mJ per pulse, continuously variable in 0.1 mJ increments Pulse Duration Burst Mode 1, 2, or 3 pulses per burst (selectable) Single pulse Spot Size Cone Angle Posterior Offset Repetition rate Aiming Beam Red diode, continuously variable with adjustable intensity Red diode, continuously variable with adjustable intensity Electrical Requirements CDRH Classification Smart Selecta Duet Table Table height Wheelchair accessible, 945 mm max, 695 mm min, travel ~250 mm (37.8 in max, 27.4 in min, travel ~10.4 in) Table width Small: 630 mm (24.8 in) Medium: 880 mm (34.5 in), Table depth Small: 400 mm (15.7 in) Medium: 450 mm (17.8 in), Table wheel base Small: 520 mm x 440 mm (20.4 in x 17.2 in), Medium: 460 mm x 830 mm (18.1 in x 32.7 in), Total system weight <60 kg Your Smart Selection for Glaucoma Care Risks and warnings: Smart Selecta Duet is intended solely for use by trained physicians. SLT: contraindicated for eyes with neovascular or angle-closure glaucoma. Risks include iritis, conjunctivitis and IOP rise. YAG: contraindicated for eyes with corneal pathologies and chronically elevated IOP. Risks include IOP rise, macular edema and retinal detachment. Refer to the operator manual for a complete list of intended use, contraindications and risks. Lumenis® Certified Service | USA Toll-free 1-877-LUMENIS (1-877-586-3647) Lumenis Inc. 1870 South Milestone Drive Salt Lake City, UT 84104 USA Tel +801-656-2300 Fax +801-656-2429 Lumenis (Germany) GmbH Heinrich-Hertz-Str 3 D-63303 Dreieich-Dreieichenhain GERMANY Tel +49 (0) 6103 8335 0 VISIBLE AND INVISIBLE LASER RADIATION AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT Nd:YAG: 532 nm, 2 mJ Max / 3 ns pulse Nd:YAG: 1064 nm, 10 mJ Max / 3 ns pulse VISIBLE LASER RADIATION DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT Diode Laser: 635 nm, <1 mW Max, CW CLASS 3B LASER PRODUCT per IEC 60825-1:2014 CLASS IIIb LASER PRODUCT per 21 CFR 1040.10 & 1040.11 Complies with 21 CFR 1040.10 & 1040.11, except for deviations pursuant to Laser Notice 50, Dated June 24, 2007 • Kresge Eye Institute, MI • Lenox Hill Hospital-Manhattan Eye, Ear and Throat Institute, NY • Mayo Clinic, MN • Medical University of South Carolina, SC • New York-Presbyterian University Hospital of Columbia and Cornell, NY • Northwestern Memorial Hospital, IL • Oregon Health and Science University Hospital, OR • Stanford Hospital and Clinics, CA • Tufts Medical Center Boston, MA • UC San Diego Medical Center, CA • UCSF Medical Center, CA • University of Chicago Medical Center, IL • University of Illinois Hospital, Chicago, IL • University of Miami Hospital, FL Laser Source Energy (power) Bascom Palmer Eye Institute-Anne Bates Leach Eye Hospital, FL Wills Eye Hospital, PA Wilmer Eye Institute, Johns Hopkins Hospital, MD Massachusetts Eye and Ear Infirmary, Massachusetts General Hospital, MA Stein and Doheny Eye Institutes, UCLA Medical Center, CA Duke University Hospital, NC Cleveland Clinic, OH University of Iowa Hospitals and Clinics, IA USC Eye Institute-Keck Medical Center of USC, CA New York Eye and Ear Infirmary, NY W.K. Kellogg Eye Center, University of Michigan, MI Cullen Eye Institute-Baylor, Methodist Hospital, TX Dean McGee Eye Institute, OU Medical Center, OK Emory University Hospital, GA Hospitals of the University of Pennsylvania-Penn Presbyterian, PA w w w. l u m e n i s . c o m / O p h t h a l m o l o g y © 2018 All Rights Reserved. The Lumenis Group of Companies. PB-2005807 Re
Open the catalog to page 1
The Smart Choice for Your Patient Lumenis, the world’s pioneer of SLT technology, celebrates Smart Selecta Duet encapsulates Lumenis’ reliable core, 20 years of SLT innovation by launching the newest anterior offering cutting edge design, enhanced optics, and a Titratable illumination of both anterior and posterior Vitreous Opacities segment laser platform, the Smart Selecta Duet. superior panel PC with adjustable display. SLT can be treated with on-axis illumination, as well as off-axis if needed Smart Selecta Duet is now available with the Smart-V upgrade: Vitreous Opacities Less red...
Open the catalog to page 2All Lumenis catalogs and technical brochures
-
OptiLIGHT
6 Pages
-
UltraPulse Alpha
8 Pages
-
AcuPulse
5 Pages
-
NuEra Tight
8 Pages
-
LightSheer Quattro
5 Pages
-
Stellar M22
8 Pages
-
Digital Duet & Trio
6 Pages
-
LightSheer® DESIRE™Light
6 Pages
Archived catalogs
-
ResurFX™
4 Pages
-
UltraPulse® DUO
5 Pages
-
UltraPulse®
6 Pages
-
Multi-SpotTM Nd:YAG
2 Pages
-
Q-Switched Nd:YAG
2 Pages
-
CO2 Laser Accessories
24 Pages
-
Peer Reviewed Articles List
6 Pages