Overview: The document provides detailed specifications and information about the Lumenis Smart Selecta Duet, a laser system used in ophthalmology for glaucoma treatment. It highlights the system's features, specifications, and the institutions that utilize it.
Specifications: The Smart Selecta Duet combines Selective Laser Trabeculoplasty (SLT) with YAG photodisruption capabilities. It operates with a Q-Switched Nd:YAG laser source at wavelengths of 532 nm and 1064 nm. The system offers energy levels from 0.3 to 10 mJ per pulse, with a pulse duration of 3 ns. It features a Super Gaussian beam profile for precise optical breakdown and is air-cooled with electrical requirements of 100-240 VAC, 50/60 Hz, 3.15 Amps.
Design and Features: The system includes a wheelchair-accessible table, a panel PC with a 12-inch adjustable touch screen, and Smart-V technology for anterior and posterior vitreous opacities illumination. It is designed for stability, reliability, and easy upgrades.
Clinical Use and Recommendations: The Smart Selecta Duet is recommended for use by trained physicians and is contraindicated for certain eye conditions. It is clinically proven as a first-line therapy for open-angle glaucoma, with a success rate of over 80% in reducing intraocular pressure (IOP). The system is used by leading ophthalmic institutions across the USA.
Safety and Compliance: The device complies with FDA and CDRH classifications and is certified under ISO 13485. It includes safety measures such as a built-in energy indicator to ensure accurate energy delivery during treatments.
Conclusion: The Smart Selecta Duet is positioned as a cutting-edge solution for glaucoma care, offering effective treatment options with a focus on patient safety and clinical efficacy. It is supported by extensive research and is a preferred choice among top ophthalmic institutions.
See more

Catalog excerpts

Smart Selecta Duet-1

Lumenis SLT The Preferred Choice of Leading Ophthalmic Institutions in the USA Q-Switched Nd:YAG Q-Switched, frequency doubled Nd:YAG 0.3 - 2.0 mJ per pulse, continuously variable in 0.1 mJ increments Pulse Duration Burst Mode 1, 2, or 3 pulses per burst (selectable) Single pulse Spot Size Cone Angle Posterior Offset Repetition rate Aiming Beam Red diode, continuously variable with adjustable intensity Red diode, continuously variable with adjustable intensity Electrical Requirements CDRH Classification Smart Selecta Duet Table Table height Wheelchair accessible, 945 mm max, 695 mm min, travel ~250 mm (37.8 in max, 27.4 in min, travel ~10.4 in) Table width Small: 630 mm (24.8 in) Medium: 880 mm (34.5 in), Table depth Small: 400 mm (15.7 in) Medium: 450 mm (17.8 in), Table wheel base Small: 520 mm x 440 mm (20.4 in x 17.2 in), Medium: 460 mm x 830 mm (18.1 in x 32.7 in), Total system weight <60 kg Your Smart Selection for Glaucoma Care Risks and warnings: Smart Selecta Duet is intended solely for use by trained physicians. SLT: contraindicated for eyes with neovascular or angle-closure glaucoma. Risks include iritis, conjunctivitis and IOP rise. YAG: contraindicated for eyes with corneal pathologies and chronically elevated IOP. Risks include IOP rise, macular edema and retinal detachment. Refer to the operator manual for a complete list of intended use, contraindications and risks. Lumenis® Certified Service | USA Toll-free 1-877-LUMENIS (1-877-586-3647) Lumenis Inc. 1870 South Milestone Drive Salt Lake City, UT 84104 USA Tel +801-656-2300 Fax +801-656-2429 Lumenis (Germany) GmbH Heinrich-Hertz-Str 3 D-63303 Dreieich-Dreieichenhain GERMANY Tel +49 (0) 6103 8335 0 VISIBLE AND INVISIBLE LASER RADIATION AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT Nd:YAG: 532 nm, 2 mJ Max / 3 ns pulse Nd:YAG: 1064 nm, 10 mJ Max / 3 ns pulse VISIBLE LASER RADIATION DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT Diode Laser: 635 nm, <1 mW Max, CW CLASS 3B LASER PRODUCT per IEC 60825-1:2014 CLASS IIIb LASER PRODUCT per 21 CFR 1040.10 & 1040.11 Complies with 21 CFR 1040.10 & 1040.11, except for deviations pursuant to Laser Notice 50, Dated June 24, 2007 • Kresge Eye Institute, MI • Lenox Hill Hospital-Manhattan Eye, Ear and Throat Institute, NY • Mayo Clinic, MN • Medical University of South Carolina, SC • New York-Presbyterian University Hospital of Columbia and Cornell, NY • Northwestern Memorial Hospital, IL • Oregon Health and Science University Hospital, OR • Stanford Hospital and Clinics, CA • Tufts Medical Center Boston, MA • UC San Diego Medical Center, CA • UCSF Medical Center, CA • University of Chicago Medical Center, IL • University of Illinois Hospital, Chicago, IL • University of Miami Hospital, FL Laser Source Energy (power) Bascom Palmer Eye Institute-Anne Bates Leach Eye Hospital, FL Wills Eye Hospital, PA Wilmer Eye Institute, Johns Hopkins Hospital, MD Massachusetts Eye and Ear Infirmary, Massachusetts General Hospital, MA Stein and Doheny Eye Institutes, UCLA Medical Center, CA Duke University Hospital, NC Cleveland Clinic, OH University of Iowa Hospitals and Clinics, IA USC Eye Institute-Keck Medical Center of USC, CA New York Eye and Ear Infirmary, NY W.K. Kellogg Eye Center, University of Michigan, MI Cullen Eye Institute-Baylor, Methodist Hospital, TX Dean McGee Eye Institute, OU Medical Center, OK Emory University Hospital, GA Hospitals of the University of Pennsylvania-Penn Presbyterian, PA w w w. l u m e n i s . c o m / O p h t h a l m o l o g y © 2018 All Rights Reserved. The Lumenis Group of Companies. PB-2005807 Re

 Open the catalog to page 1
Smart Selecta Duet-2

The Smart Choice for Your Patient Lumenis, the world’s pioneer of SLT technology, celebrates Smart Selecta Duet encapsulates Lumenis’ reliable core, 20 years of SLT innovation by launching the newest anterior offering cutting edge design, enhanced optics, and a Titratable illumination of both anterior and posterior Vitreous Opacities segment laser platform, the Smart Selecta Duet. superior panel PC with adjustable display. SLT can be treated with on-axis illumination, as well as off-axis if needed Smart Selecta Duet is now available with the Smart-V upgrade: Vitreous Opacities Less red reflex:...