MAGPIX®
2Pages

{{requestButtons}}

Catalog excerpts

MAGPIX® - 1

System Specifications Accuracy and Precision • Sample uptake volume ±5% • Classification of microspheres >80% • Misclassification of microspheres < 2% • Distinguishes 1 to 50 unique xMAP® microspheres in a single sample • Temperature control ±1°C of target • Sample carryover < 4% • Soluble background fluorescence emissions at 590 nm ± 24 nm automatically subtracted from fluorescence intensity values Sensitivity • Detect < 700 fluorochromes phycoerythrin (PE) per xMAP microsphere Optics • Reporter channel, LED excitation: 511nm ± 27 nm • Minimum reporter channel dynamic range: 3 decades of detection o Typical Dynamic Range: > 3.5 decades of detection • Reporter / Classification detector: CCD • Reporter / Classification A/D resolution 16 bits • Focus Lens: 5x magnification Fluidics • 96 well plate capability with additional off plate reagent area • Piercing probe capability • Auto adjusting probe capability • Sample uptake volume 20uL - 200uL. • Internal / removable drive bottle and waste bottle • Disposable Drive bottle volume: 650mL (8 plates) • Waste bottle volume: 850mL Electronics: • USB 2.0 communications • Input voltage range: 100 - 120 or 200 -240 VAC and 50 - 60Hz Setup • Installation < 2 hours • System calibration < 10 minutes Capacity • Analyze multiple 96-well plates per batch • Analyze multiple assay templates per plate • Automatic sampling from a 96-well plate. The following microtiter plates are compatible with the MAGPIX plate holder: flat bottom, conical, round, filter bottom, [overall height no more than 0.75” (19mm)], any color • Drive and waste bottles hold enough volume to run up to eight 96-well plates between refills • Detect and distinguish surface reporter fluorescence emissions at 590 nm ± 24 nm on the surface of 1-50 unique xMAP microsphere sets in a single sample General • Physical dimensions: 16.5cm (6.5 inches) W x 60cm (23.5 inches) D x 43cm (17 inches) H. Additional space required for the monitor/PC stand, keyboard, mouse and barcode scanner does not exceed 64.8cm (25.5 inches) W x 61cm (24 inches) • Weight: up to 18kg (40lbs) • Operating Environment: • Temperature: 15°C - 35°C (59°F - 95°F) • Humidity: 20% - 80%RH, noncondensing

Open the catalog to page 1
MAGPIX® - 2

General (continued) • Altitude: up to 2400m (7874 ft) above mean sea level • Temperature control: Maintains samples at a constant temperature from 35 °C -60 °C (95°F - 131 °F) o Warm up time: 15 minutes • Plate throughput time: < 60 minutes Monitor Specifications • Screen resolution and number of colors: SXGA 1280 x 1024 with 32-bit color • Screen size: 43cm (17”) PC Specifications • Processor: 2.8 GHz Intel® Core 2 or higher • Main memory: 4 G RAM or higher • Hard disk drive: 80 GB or higher (160 GB recommended) • Communication/Ports: four USB version 2.0 compatible high speed ports •...

Open the catalog to page 2

All Luminex Corporation catalogs and technical brochures

  1. FLEXMAP

    2 Pages

  2. ARIES®

    2 Pages