Datalys 750
2Pages

{{requestButtons}}

Catalog excerpts

Datalys 750 - 1

Safety ISO 13485:2003 approved CE marking according to MDD93/42/EEC Degree of protection against harmful ingress of water: IP X 1 RR Range: RR Resoultion: RRate Accuracy: Apnea Alarm: Alarm: Dimension and Weight Dimension: Net Weight: Gross Weight: Operation Environment Power: Temperature: Humidity: Patient Range Patients: Neonate, Pediatric, or Adult Performance Specifications Display: 8.4inch TFT Color Touch Resolution: Trace: Indicator: Trend Time: Alarm: Networking: Recorder (Optional): Record Mode: Record Speed: Paper Width: 800 X 600 Maximum 8 waveforms display Power, Battery, Alarm lights and QRS, Operating Key, Alarm sounds Parameter cable interface AC power input socket Network interface USB port Lithium polymer plug & play rechargeable battery (4 hours of continuous working time) 120 hours Audible and visual alarms with user-adjustable high and low limits Connects to central monitoring system (LAN or Wireless) Built-in thermal array, 2 channels Manual, Upon alarm, Continual, or Time-defined 25mm/s or 50mm/s 1.97in (50mm) Adu/Ped: 0-120rpm Neo: 0-150rpm 1rpm ±1rpm Yes, 10-40s User-adjustable high and low limits CO2 (Optional) Measurement Method: Non-dispersive infrared (NDIR) Respironics CO2 Mainstream (Capnostat 5): Lutech SpO2 Saturation Range: 1-100% Saturation Resolution: 1% Saturation Accuracy: ±2% (70-100%, Adu/Ped) ±5bpm (motion) Alarm: User-adjustable high, mid, low limit ranges Nellcor SpO2 (Optional) Saturation Accuracy: ±3% (70-100%) Unspecified (0-69%) PR Range: 20-250bpm Masimo SpO2 (Optional) Saturation Accuracy: ±2% (70-100%, Adu/Ped) ±3% (70-100%, Neo) Unspecified (0-69%) PR Range: 25-240bpm NIBP Measurement Method: Automatic oscillometric Manual, Automatic Adjustable 1-480min Systolic, Diastolic, Mean mmHg/kPa selectable RR Range: Sidestream (LoFlo): CO2 Range: CO2 Accuracy: PhaseIn CO2 Mainstream (IRMA) or Sidestream (ISA) PhaseIn Anaesthetic Gas (Optional) Measurement Method: Non-dispersive infrared (NDIR) Mainstream (IRMA AX+): ECG Lead Selection: Gain Selection: Sweep Speed: Filter Bandwidth: HR Range: HR Resolution: HR Accuracy: HR Alarming Time: ST Segment Detection Alarm: Arrhythmia Analysis: Alarm: Anti-Electrical Interference 3-lead, 5-lead, 12-lead X1/4, X1/2, X1, X2, X4, Auto 6.25mm/s, 12.5mm/s, 25mm/s, or 50mm/s Mon: 0.5-40Hz DIA: 0.05-130Hz OPE: 1-20Hz Adu: 15-300bpm Ped/Neo: 15-350bpm 1bpm ±1% or ±2bpm <12s -0.20mV-0.20mV (default) Yes User-adjustable high, mid, low limit ranges Line frequency, electro-surgery and defibrillation protection, pacemaker detection Respiration Measurement Method: Thoracic impedance Measurement Modes Auto Mode Times: Pressure Types: Pressure Units: Pressure Range: Range for Systolic Pressure: Adu: 40-270mmHg Ped: 40-200mmHg Neo: 40-135mmHg Range for Diastolic Pressure: Adu: 10-215m mHg Ped: 10-150mmHg Neo: 10-100mmHg Range for Mean Pressure: Adu: 20-235mmHg Alarm Type: Pressure Accuracy: PR Range: Over-Pressure Protection: Temperature Temp Units: Temp Range: Temp Resolution: Temp Accuracy: IBP (Optional) Measured Pressures: Pressure Units: Pressure Range: Pressure Accuracy: CO2: 0-10vol% N2O: 0-100vol% HAL: 0-8vol% ISO: 0-8vol% ENF: 0-8vol% SEV: 0-10vol% DES: 0-22vol% CO2: ±0.3vol%+2% of reading N2O: ±0.2vol%+2% of reading HAL: ±0.15vol%+5% of reading ISO: ±0.15vol%+5% of reading ENF: ±0.15vol%+5% of reading SEV: ±0.15vol%+5% of reading DES: ±0.15vol%+5% of reading 0-150rpm Ped: 20-165mmHg Neo: 20-110mmHg Systolic, Diastolic, Mean ±5mmHg 40-240bpm Adu: 300mmHg Ped: 240mmHg Neo: 150mmHg CO2: 0-10vol% N2O: 0-100vol% HAL: 0-8vol% ISO: 0-8vol% ENF: 0-8vol% SEV: 0-10vol% DES: 0-22vol% O2: 0-100% (for ISA OR+ only) CO2: ±0.2vol%+2% of reading N2O: ±0.2vol%+2% of reading HAL: ±0.15vol%+5% of reading ISO: ±0.15vol%+5% of reading ENF: ±0.15vol%+5% of reading SEV: ±0.15vol%+5% of reading DES: ±0.15vol%+5% of reading O2: ±1vol%+2% of reading (for ISA OR+ only) 0-150rpm Standard Configuration ECG/HR, Lutech SpO2, NIBP, Resp., Temp., and Pulse Rate. Optional Configuration Nellcor SpO2, Masimo SpO2, IBP, Respironics or PhaseIn CO2 (Mainstream or Sidestream), PhaseIn Anaesthetic Gas (Mainstream or Sidestream), Recorder, Central Monitoring System (LAN or Wireless, HL-7), Special parameters for neonate and pediatric patients. LUTECH INDUSTRIES, INC. 105 Remington Blvd., Suite C, Ronkonkoma, NY 11779 U.S.A. Ph: 631-676-7432 Fx: 631-619-0723 Website: www.lutechmedical.com E-mail: info@lutechmedical.com V2.1 - 03/05/2019

Open the catalog to page 1
Datalys 750 - 2

User-friendly Interface Multi interface support, including standard display, large-font display, trend coexist display, bed-to-bed view display, and OxyCRG dynamic view display, color of waveform and parameter is changeable. Super Reliability The design and production of product strictly comply with the CE standards. The safety, stability and durability of the product are well guaranteed. At least 10 days of aging inspection to maintain product’s reliability. Rich Clinical Information Excellent software processing techniques, including arrhythmia analysis, pacemaker analysis, OxyCRG, S-T...

Open the catalog to page 2

All Lutech Industries catalogs and technical brochures

  1. Datalys 780

    2 Pages

  2. LT-300 HD

    2 Pages

  3. Datalys 760

    4 Pages