Product catalog summary
Overview: The document outlines the specifications and operational guidelines for MAC Valves Series 45, focusing on solenoid and solenoid pilot-operated valves. It covers valve configurations, technical data, and ordering instructions.
Specifications: Series 45 valves offer single and double solenoid or remote air options, featuring a patented MACSOLENOID® for fast response times. The balanced poppet design ensures high flow, precise repeatability, and consistent operation. Configurations include 4-way, 3-way, or 2-way, suitable for vacuum, diverter, or selector applications. They are designed for both lube and non-lube service, with high cycle rates and long service life due to unique poppet cushions.
Technical Data: These valves operate with compressed air, vacuum, or inert gases, with a pressure range from vacuum to 120 PSI. Lubrication is not required but can be used if needed. The filtration requirement is 40 µ, and the temperature range is 0°F to 120°F (-18°C to 50°C). The valves offer various flow rates depending on wattage, with a leak rate of 100 cm3/min. Solenoids are encapsulated for continuous duty with a voltage range of -15% to +10% of nominal voltage.
Operational Benefits: The valves feature a balanced poppet design immune to pressure variations, a short stroke for high flow, and a powerful return spring. A manual operator is standard, and the valves are burn-out proof on AC service.
Ordering Information: Detailed ordering codes are provided for different configurations, including port sizes, voltage options, wire lengths, manual operator types, and electrical connections. Spare parts and customization options are also listed.
Applications: The balanced poppet design allows the same valve to be used for multiple functions, including pressure, vacuum, or plugged applications without changing parts. Piping suggestions are provided for various configurations.
Dimensions: Detailed dimensions for various valve configurations are included, with measurements in metric units.
Additional Notes: Consult the 'Precautions' section on page 356 before use, installation, or service of MAC Valves.
See more

Catalog excerpts

45 Series-1

Direct solenoid and solenoid pilot operated valvesSeries 45 individual mounting Series inline Manual operator C_SERIES FEATURES • Single and double solenoid or remote air. • The patented MACSOLENOID® for fastest possible response times. • Bonded balanced poppets for high flow, precise repeatability, and consistent operation. • Balanced poppet design permits versatility in pipping. Valves can be piped as 4-way, 3-way or 2-way, normally closed or normally open or can be used for vacuum, diverter or selector applications. • Use on lube or non-lube service. • Extremely high cycle rates. • Extremely long service life due to unique poppet cushions. • Manual overrides as standard. • Various solenoid enclosures and plug-in connectors • Optional surge suppression available. • Low wattage DC solenoids — down to 1.8 watts. • Patented MACSOLENOID® — virtually burn-out proof on AC service. Consult "Precautions" page 356 before use, installation or service of MAC Valves.

 Open the catalog to page 1
45 Series-2

• 2-position single and double solenoid or remote air. • Single pressure (4 or 5 ports) • Individual, stacking and manifold base mounted models. • Integral individual exhaust flow controls with common exhaust port. • Integral regulators and flow controls on manifolds. The balanced poppet design facilities using the same valve for many functions and can be used for pressure, vacuum or plugged without the necessity of changing any parts. Pipping suggestions are shown in the chart below. NORMALLY CLOSED NORMALLY OPEN NORMALLY OPEN Operator De-Energized Operator Energized SELECTOR "A" CAN BE USED...

 Open the catalog to page 2
45 Series-3

Direct solenoid and solenoid pilot operated valves 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. 35 Port size Single operator Double operator (Minimum DC wattage 5.4W) 100 WITH INTEGRATED FLOW CONTROLS Port size Single operator Double operator (Minimum DC wattage 5.4W) EXH KD Square connector with light JB_Rectangular connector_ JD Rectangular connector with light * Other options available,...

 Open the catalog to page 3
45 Series-4

Series 45 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : Leak rate : General purpose class A, continuous duty, encapsulated Voltage range : Consult factory Spare parts : • Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Valve cover plate with flow controls : N-45002. • BSPP threads. • High flow up to 0.23 Cv, according to wattage and high flow Mod. • NAMUR interface - 45A-FA1DXXX-XXX...

 Open the catalog to page 4
45 Series-5

1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. WITH INTEGRATED FLOW CONTROLS 1/8" NPTF base Square connectoi KD Square connector with lighl * Other options available, see page 353. Substitute "J" for 1/8" bottom cylinder ports Consult "Precautions" page 356 before use, installation or service of MAC Valves.

 Open the catalog to page 5
45 Series-6

TECHNICAL DATA Compressed air, vacuum, inert gases Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) 40 p General purpose class A, continuous duty, encapsulated -15% to +10% of nominal voltage Consult factory Spare parts : • Solenoid operator (power > 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Flow control : N-45018. • BSPP threads. • High flow up to 0.20 Cv, according to wattage and high flow mod. Dimensions shown are metric (mm) Port size...

 Open the catalog to page 6
45 Series-7

Direct solenoid and solenoid pilot operated valves 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. Port size Single operator Double operator (Minimum DC wattage 5,4W) WITH INTEGRATED FLOW CONTROLS Port size Single operator Double operator SOLENOID OPERATOR v D XXX-XXX KD Square connector with lighl * Other options available, see page 353. End plate kit required (Port size 1/4" NPTF) : M-45001-01....

 Open the catalog to page 7
45 Series-8

TECHNICAL DATA Compressed air, vacuum, inert gases Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) 40 p General purpose class A, continuous duty, encapsulated -15% to +10% of nominal voltage Consult factory Spare parts : • Solenoid operator (power > 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between valves : 16422. • Tie-rod (x2) : 19813. • Valve cover plate with flow controls : N-45004. • Inlet & exhaust isolator : N-45005. Inlet isolator : N-45006. Exhaust isolator : N-45007...

 Open the catalog to page 8
45 Series-9

1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. WITH INTEGRATED FLOW CONTROLS 1/8" NPTF base 45A-LAD-DXXX-XXX KD Square connector with light * Other options available, see page 353. End plate kit required (Port size 1/4" NPTF) : M-45008-01 Consult "Precautions" page 356 before use, installation or service of MAC Valves.

 Open the catalog to page 9
45 Series-10

TECHNICAL DATA Compressed air, vacuum, inert gases Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) 40 p General purpose class A, continuous duty, encapsulated -15% to +10% of nominal voltage Consult factory Spare parts : • Solenoid operator (power > 5.4 W) : DXXX-XXX, including mounting screws 35013. • Seal (between solenoid and valve body) : 16402. • Seal between base and valve : 16453. • Seal between bases : 16455. • Tie-rod (x2) : 19753. • Side cover plate with flow controls : N-45016. • Inlet & exhaust isolator : N-45008. • Inlet isolator...

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.