Direct solenoid and solenoid pilot operated valves Series 47 individual mounting Series Inline • Short stroke solenoid produces high energization shifting force. • High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. • Built-in wear compensation - valve stroke is shorter than solenoid stroke. • Four (4) bonded balanced poppets on a one-piece valve stem. • End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. • Exhaust seals are not under inlet pressure thus reducing friction. • Short stroking balanced poppet allows for direct solenoid operation with high shifting forces, minimized friction, fast response and high flow in a small package. Consult "Precautions" page 327 before use, installation or service of MAC Valves..
Open the catalog to page 1Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow [Max] Individual Mounting OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force. 2. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. 3. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a one-piece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing...
Open the catalog to page 2Series 47 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : Class A wire (#22 AWG x 18), continuous duty Voltage range : Response times : • BSPP threads Spare parts : • Flow control assembly : N-47004 Dimensions shown are metric (mm) OPTIONAL FLOW CONTROL COVER Consult “Precautions” page 327 before use, installation or
Open the catalog to page 3Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow [Max] Individual Mounting OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force. 2. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. 3. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a one-piece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing...
Open the catalog to page 4TECHNICAL DATA Pressure range : Lubrication : Filtration : Temperature range : Flow : Voltage range : Power : Response times : (with 5.2 W coil) Compressed air, vacuum, inert gases Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) 40 p Class A wire (#22 AWG x 18), continuous duty -15% to +10% of nominal voltage 5.2W - 2.4W - 1.0W Energize : 17.4 ms De-energize : 3.8 ms Options : • BSPP threads Spare parts : • Pressure seal body to base: 16628 • Mounting screw (x2): 35043 • Flow control assembly (x2): N-04001 Dimensions shown are metric (mm)...
Open the catalog to page 5Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow [Max] Manifold Mounting OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force. 2. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. 3. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a one-piece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing...
Open the catalog to page 6Pressure range : Lubrication : Filtration : Temperature range : Flow : Voltage range : Power : Response times : (with 5.2 W coil) Compressed air, vacuum, inert gases Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) 40 p Class A wires (#22 AWG x 18), continuous duty -15% to +10% of nominal voltage 5.2W - 2.4W - 1.0W Energize : 17.4 ms De-energize : 3.8 ms Options : • BSPP threads Spare parts : • Inlet isolator: 28451 • Exhaust isolator: N-47009 • Tie Rod (x2): 79057 Dimensions shown are metric (mm) Consult "Precautions" page 327 before use,...
Open the catalog to page 7Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow [Max] Manifold Mounting Series Manifold base "plug-in" OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force. 2. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. 3. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a one-piece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not...
Open the catalog to page 8Series 47 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : Class A continuous duty, #22 AWG x 12 base leads Voltage range : Response times : • BSPP threads • Sandwich flow control: FC47A-AA • Sandwich regulator: see”Regulator” section Spare parts : • Inlet/exhaust isolator: 28447 • Valve cover plate: M-47001 Dimensions shown are metric (mm) 101.0 3/8" N.P.T.F. 3 HOLES BOTH ENDS 1/2"-14 N.P.S.M. CONDUIT BOTH ENDS OPTIONAL SANDWICH REGULATOR SHOWN Consult “Precautions”...
Open the catalog to page 9Codification table for voltages / Manual operators / Electrical connections - Solenoid valves 37 & 47 Series Consult “Precautions” page 327 before use, installation or service of MAC Valves
Open the catalog to page 10BA with full wave rectifier & ground wire VOLTAGE BT BA with full wave rectifier plus light 120/50, 120/60 (6.7 W) BU BA with full wave rectifier plus light & ground wire (use connector with rectifier) 220/50, 220/60 (5.6 W) (use connector with rectifier) 240/50, 240/60 (5.8 W) (use connector with rectifier) (use connector with rectifier) FB FA with ground wire FD FA with light & ground wire FE FA with suppression diode FF FAwith suppression diode & ground wire FG FA with suppression diode & light FH FA with suppression diode plus light & ground wire FK FA with full wave rectifier FL FA with...
Open the catalog to page 113 Pages
2 Pages
3 Pages
3 Pages
10 Pages
10 Pages
13 Pages
20 Pages
15 Pages
18 Pages
3 Pages
5 Pages
2 Pages
13 Pages
10 Pages
9 Pages
24 Pages
89 Pages
359 Pages
277 Pages
1 Page