video corpo

47 Series

47 Series
1 / 11 PagesView full catalog

47 Series

Product catalog summary
Overview: The document outlines configurations for wire assemblies and mini square connectors, emphasizing solenoid plug-in wire assemblies. Components include suppression diodes, full wave rectifiers, lights, and ground wires.
Wire Assemblies:
  • FT FA: Features a full wave rectifier and light.
  • FU FA: Similar to FT FA with an additional ground wire.
  • MA: Basic solenoid plug-in wire assembly.
  • MB: MA with an added ground wire.
  • MC: MA with an added light.
  • MD: MA with both light and ground wire.
  • ME: MA with a suppression diode.
  • MF: ME with an added ground wire.
  • MG: ME with an added light.
  • MH: ME with both light and ground wire.
  • MK: MA with a full wave rectifier.
  • ML: MK with an added ground wire.
  • MN: MA with both suppression and blocking diodes.
  • MP: MN with an added ground wire.
  • MR: MN with an added light.
  • MS: MN with both light and ground wire.
  • MT: MA with a full wave rectifier and light.
  • MU: MT with an added ground wire.
  • MJ: Plug-in housing without wire assembly (MA option).
  • MM: Plug-in housing without wire assembly (MB option).
Mini Square Connectors:
  • KA: Basic mini square connector.
  • KB: KA with a suppression diode.
  • KC: KA with a Metal Oxide Varistor (M.O.V.).
  • KD: KA with an added light.
  • KE: KD with a suppression diode.
  • KF: KD with an M.O.V.
  • KJ: Male-only mini square connector.
  • KK: KJ with a suppression diode.
  • KL: KJ with an M.O.V.
  • KM: KA with a full wave rectifier.
  • KN: KM with an M.O.V.
  • KP: KA with a full wave rectifier and light.
  • KR: KP with an M.O.V.
  • KS: KJ with a full wave rectifier.
Notes:
  • Blocking diodes are located in the lead wire.
See more

Catalog excerpts

47 Series-1

Direct solenoid and solenoid pilot operated valves Series 47 individual mounting Series Inline • Short stroke solenoid produces high energization shifting force. • High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. • Built-in wear compensation - valve stroke is shorter than solenoid stroke. • Four (4) bonded balanced poppets on a one-piece valve stem. • End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. • Exhaust seals are not under inlet pressure thus reducing friction. • Short stroking balanced poppet allows for direct solenoid operation with high shifting forces, minimized friction, fast response and high flow in a small package. Consult "Precautions" page 327 before use, installation or service of MAC Valves..

 Open the catalog to page 1
47 Series-2

Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow [Max] Individual Mounting OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force. 2. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. 3. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a one-piece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing...

 Open the catalog to page 2
47 Series-3

Series 47 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : Class A wire (#22 AWG x 18), continuous duty Voltage range : Response times : • BSPP threads Spare parts : • Flow control assembly : N-47004 Dimensions shown are metric (mm) OPTIONAL FLOW CONTROL COVER Consult “Precautions” page 327 before use, installation or

 Open the catalog to page 3
47 Series-4

Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow [Max] Individual Mounting OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force. 2. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. 3. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a one-piece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing...

 Open the catalog to page 4
47 Series-5

TECHNICAL DATA Pressure range : Lubrication : Filtration : Temperature range : Flow : Voltage range : Power : Response times : (with 5.2 W coil) Compressed air, vacuum, inert gases Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) 40 p Class A wire (#22 AWG x 18), continuous duty -15% to +10% of nominal voltage 5.2W - 2.4W - 1.0W Energize : 17.4 ms De-energize : 3.8 ms Options : • BSPP threads Spare parts : • Pressure seal body to base: 16628 • Mounting screw (x2): 35043 • Flow control assembly (x2): N-04001 Dimensions shown are metric (mm)...

 Open the catalog to page 5
47 Series-6

Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow [Max] Manifold Mounting OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force. 2. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. 3. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a one-piece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing...

 Open the catalog to page 6
47 Series-7

Pressure range : Lubrication : Filtration : Temperature range : Flow : Voltage range : Power : Response times : (with 5.2 W coil) Compressed air, vacuum, inert gases Vacuum to 120 PSI Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) 40 p Class A wires (#22 AWG x 18), continuous duty -15% to +10% of nominal voltage 5.2W - 2.4W - 1.0W Energize : 17.4 ms De-energize : 3.8 ms Options : • BSPP threads Spare parts : • Inlet isolator: 28451 • Exhaust isolator: N-47009 • Tie Rod (x2): 79057 Dimensions shown are metric (mm) Consult "Precautions" page 327 before use,...

 Open the catalog to page 7
47 Series-8

Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow [Max] Manifold Mounting Series Manifold base "plug-in" OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force. 2. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. 3. Built-in wear compensation - valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a one-piece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not...

 Open the catalog to page 8
47 Series-9

Series 47 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : Class A continuous duty, #22 AWG x 12 base leads Voltage range : Response times : • BSPP threads • Sandwich flow control: FC47A-AA • Sandwich regulator: see”Regulator” section Spare parts : • Inlet/exhaust isolator: 28447 • Valve cover plate: M-47001 Dimensions shown are metric (mm) 101.0 3/8" N.P.T.F. 3 HOLES BOTH ENDS 1/2"-14 N.P.S.M. CONDUIT BOTH ENDS OPTIONAL SANDWICH REGULATOR SHOWN Consult “Precautions”...

 Open the catalog to page 9
47 Series-10

Codification table for voltages / Manual operators / Electrical connections - Solenoid valves 37 & 47 Series Consult “Precautions” page 327 before use, installation or service of MAC Valves

 Open the catalog to page 10
47 Series-11

BA with full wave rectifier & ground wire VOLTAGE BT BA with full wave rectifier plus light 120/50, 120/60 (6.7 W) BU BA with full wave rectifier plus light & ground wire (use connector with rectifier) 220/50, 220/60 (5.6 W) (use connector with rectifier) 240/50, 240/60 (5.8 W) (use connector with rectifier) (use connector with rectifier) FB FA with ground wire FD FA with light & ground wire FE FA with suppression diode FF FAwith suppression diode & ground wire FG FA with suppression diode & light FH FA with suppression diode plus light & ground wire FK FA with full wave rectifier FL FA with...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.