Introduction to Differential Scanning Calorimetry (DSC)
Differential Scanning Calorimetry (DSC) is a technique for assessing the thermal stability of proteins and biomolecules by detecting heat absorption during conformational changes. Key parameters include the thermal transition midpoint (TM), enthalpy, and heat capacity, which indicate molecular stability and interactions.
What is DSC?
A DSC thermogram shows protein unfolding, with multiple peaks for different domains. The TM indicates thermal stability, with higher values showing greater stability.
Why Use DSC?
DSC is crucial in biopharmaceutical development for optimizing stability, purification, and biosimilarity assessment. It is also used in drug development and academia for analyzing protein folding and transitions.
MicroCal PEAQ-DSC Key Features
The MicroCal PEAQ-DSC system offers sensitive microcalorimetry with features like unattended operation, tight binding constant measurement, and regulatory compliance. It supports automated data analysis and is network-ready.
MicroCal PEAQ-DSC Automated
This system provides high throughput and sensitivity with automated cell filling and cleaning, supporting up to 50 samples per day. It integrates into existing data systems and complies with regulations.
PEAQ-Compliance
The PEAQ-Compliance software ensures compliance with 21 CFR Part 11 and Annex 11, managing electronic records with audit trails and user authentication, essential for QC and method development.
PEAQ-Performance
PEAQ-Performance simplifies performance qualification checks, ensuring the instrument operates within criteria. It automates system readiness checks and baseline stability for reliable data.
PEAQ-Smart
PEAQ-Smart enhances control and data analysis with features like SOP-Builder, automated data analysis, and PEAQ-Finder for multi-peak identification, improving experimental design and data accuracy.
PEAQ-Compare
PEAQ-Compare facilitates DSC thermogram comparison for biosimilarity and batch analysis, providing quantitative similarity assessments and detailed residual data.
Product Specifications
The document details specifications for automated and manual MicroCal PEAQ-DSC systems, including measurement parameters, sample capacity, and compliance features.
Company Overview: Malvern Panalytical is a leader in materials characterization, providing solutions that enhance productivity through chemical, physical, and structural analysis. It is part of Spectris, a productivity-enhancing company.
Support and Services: Malvern Panalytical offers support services, including local and remote support, flexible agreements, compliance support, and training courses. They provide consultancy to maximize productivity and efficiency.
Mission: The mission is to help clients develop better products and bring them to market faster, supporting research excellence and productivity.
Disclaimer: The document includes a disclaimer about the accuracy of the information, stating no liability for errors or damages and reserving the right to change content without notice.
Contact Information: Malvern Panalytical is headquartered in Malvern, UK, with contact details for UK and Netherlands offices.
See more

Catalog excerpts

MicroCal PEAQ-DSC Automated-1

MICROCAL PEAQ-DSC Biomolecular stability analysis for the regulated environment

 Open the catalog to page 1
MicroCal PEAQ-DSC Automated-2

INTRODUCTION TO DIFFERENTIAL SCANNING CALORIMETRY (DSC) WHAT IS DSC? Differential Scanning Calorimetry (DSC) is a powerful analytical technique which characterizes the thermal stability of proteins and other biomolecules. In solution, these molecules often undergo thermally-induced conformational changes, such as the breaking of non-covalent bonds leading to the unfolding of a protein. These types of structural rearrangement are detectable by DSC as they require the absorption of energy in the form of heat. Even in dilute solutions of protein, the new MicroCal PEAQDSC systems detect such heat...

 Open the catalog to page 2
MicroCal PEAQ-DSC Automated-3

MICROCAL PEAQ-DSC MICROCAL PEAQ-DSC AUTOMATED MicroCal PEAQ-DSC MicroCal PEAQ-DSC Automated The MicroCal PEAQ-DSC system provides highly sensitive, easy-to-use microcalorimetry that helps reduce the time and cost associated with stability testing and comparability analysis. This is a manual instrument with a cleaning device, which can be upgraded to the automated version upon request. This complete system requires no additional accessories, reagents or consumables. The integrated software and automated data analysis support the generation of non-subjective, highly reproducible thermal stability...

 Open the catalog to page 3
MicroCal PEAQ-DSC Automated-4

PEAQ-PERFORMANCE21 CFR Part 11 and Annex 11 Compliance software: Keep your system performing perfectlyDSC for the regulated environment The all-new MicroCal PEAQ-DSC software is available with an optional 21 CFR Part 11 compliance module. This makes both MicroCal PEAQ-DSC systems perfect for QC-type work, including root cause analysis and in-process measurements. Malvern has a wealth of experience working in cGxP environments. We understand the need for easy-to-use analytical systems that enable robust method development and transfer, with the support of 21 CFR Part 11 and also Annex 11 compliance...

 Open the catalog to page 4
MicroCal PEAQ-DSC Automated-5

PEAQ-COMPAREEasy experimental set-up, fast and intuitive data analysis and report generationDirectly compare DSC thermograms, between molecules and between batches PEAQ-Smart provides new and improved control and data analysis for faster experimental design and implementation. Embedded videos are included to give a visual overview of DSC experimental design and also guide maintenance of the system - these help users of every level proceed with confidence. In addition, a new PEAQ-Smart report designer is included. An SOP-Builder is built-in, to guide and accelerate experimental setup and provide...

 Open the catalog to page 5
MicroCal PEAQ-DSC Automated-6

11PRODUCT SPECIFICATIONS AT A GLANCE Parameter 1Sample dependent; 2Typical results for ribonuclease (RNase) in 50 mM KAc buffer at pH 5.5, at 60°C/h with high feedback; 3Rescans of a stable buffer; 4Using ribonuclease (RNase); 5Range may be extended down to -10°C upon request

 Open the catalog to page 6
MicroCal PEAQ-DSC Automated-7

WHY CHOOSE MALVERN PANALYTICAL? We are global leaders in materials characterization, creating superior, customer-focused solutions and services which supply tangible economic impact through chemical, physical and structural analysis. Our aim is to help you develop better quality products and get them to market faster. Our solutions support excellence in research, and help maximize productivity and process efficiency. Malvern Panalytical is part of Spectris, the productivity-enhancing instrumentation and controls company. www.spectris.com SERVICE & SUPPORT Malvern Panalytical provides the global...

 Open the catalog to page 7
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.