Overview: This document is a catalog for Manfredi's Kalostery series of professional sterilizers, detailing models B, S, and N, along with their specifications, features, and accessories.
Kalostery Models:
  • Kalostery B: Equipped with a fractionated vacuum system, high-performance double-stage vacuum pump, motor-operated closure with triple protection, instantaneous vaporizer, electronic drying in vacuum, and a thermal printer for cycle recording.
  • Kalostery S: Similar to the B model, it includes pre and post vacuum phases, a motor-operated closure, instantaneous vaporizer, and a multi-language graphic display.
  • Kalostery N: Fully automatic with microprocessor control, thermodynamic vacuum system, LCD display, double safety sensors, and electronic transducers for precise pressure control.
Technical Features:
  • All models feature stainless steel chambers, options for connection to demineralization systems, thermal printers, and data logging capabilities.
  • They support sterilization cycles for solid, hollow, and porous materials, including specific programs for Bowie & Dick and vacuum tests.
Programs Menu: The catalog specifies sterilization programs for each model, detailing the types of materials and instruments that can be sterilized, along with cycle times and temperatures.
Accessories and Optionals:
  • AQUAMED: A water demineralizer with visual conductibility control.
  • STS-DATALOGGER USB: A data acquisition device for direct recording on a USB key, with evaluation software.
  • SEALING MACHINE TERMOSEAL: An ergonomic sealing machine with fast sealing times and a concealed roll-holder.
Specifications:
- Power absorbed: 100 W
- Weight: 9 kg
- Product: OSMO 2, an osmotic system with high purification capacity, suitable for use with an autoclave and an optional 16 Lt tank.
Testing Procedures for Autoclaves:
- Helix Test: Verifies sterilization inside hollow instruments.
- Bowie & Dick Test: Verifies sterilization in porous materials.
- Chemical Indicators: Used to verify each sterilization cycle.
- Biological Control: Uses spores for biological control of sterilization.
Water Distillation:
- Product: PERFECT WATER, an electrical water distiller.
Applicable Directives and Standards for Autoclaves:
- Medical Devices Directive 93/42/CE
- Pressure Vessels Directive 97/23/CE
- Small Steam Sterilizers Directive EN13060 (excluding Kalostery N)
- Electromagnetic Compatibility Directive CEI EN 61010-1
- Safety Instructions for Laboratory Apparatus CEI EN 61010-1
- Safety Requirements for Sterilizers and Washer-Disinfectors CEI EN 61010-2-40
Manufacturer's Note:
- Manfredi reserves the right to make modifications without prior warning.
See more

Catalog excerpts

KALOSTERY AUTOCLAVES-1

sterilizzazione professionale professional sterilization Italian tecnology since 1934

 Open the catalog to page 1
KALOSTERY AUTOCLAVES-3

logo fornetti 1-10-2009 12:08 Pagina 3 Sterilizzatori professional!

 Open the catalog to page 3
KALOSTERY AUTOCLAVES-4

catalogo fornetti Affidabilità e semplicità nella sterilizzazione professionale Reliability and semplicity all in one professional strarization system

 Open the catalog to page 4
KALOSTERY AUTOCLAVES-6

catalogo fornetti Vuoto frazionato Con pompa vuoto bistadio ad alto rendimento Fractionated vacuum Using a high-performance Double-stage Vacuum pump pressione pressure BOWIE & DICK HELIX TEST VACUUM TEST tempo time Grafico ciclo completo Kalostery B Complete graphic cycle Kalostery B T3

 Open the catalog to page 6
KALOSTERY AUTOCLAVES-7

catalogo fornetti CARATTERISTICHE FEATURES PRODOTTI STERILIZZABILI STERILIZABLE PRODUCTS CHIUSURA MOTORIZZATA dotata di tripla protezione, garantisce un’assoluta sicurezza, una maggiore praticità ed un’affidabile autoregolazione del portello MOTOR-OPERATED CLOSURE with triple-protection, guarantees a total safety, greater ease of handling and a reliable self-regulation of the hatch VAPORIZZATORE ISTANTANEO esterno alla camera, consente una maggior velocità dei cicli di sterilizzazione e diminuisce i consumi di acqua ISTANTANEOUS VAPORIZER outside the chamber allows higher sterilization speeds...

 Open the catalog to page 7
KALOSTERY AUTOCLAVES-8

catalogo fornetti 1-10-2009 12:08 Pagina Con pompa vuoto bistadio With Double-stage Vacuum pump BOWIE & DICK VACUUM TEST Grafico ciclo completo Kalostery S Complete graphic cycle Kalostery S

 Open the catalog to page 8
KALOSTERY AUTOCLAVES-9

catalogo fornetti CARATTERISTICHE FEATURES PRODOTTI STERILIZZABILI STERILIZABLE PRODUCTS CHIUSURA MOTORIZZATA dotata di tripla protezione, garantisce un’assoluta sicurezza, una maggiore praticità ed un’affidabile autoregolazione del portello MOTOR-OPERATED CLOSURE with triple-protection, guarantees a total safety, greater ease of handling and a reliable self-regulation of the hatch VAPORIZZATORE ISTANTANEO esterno alla camera, consente una maggior velocità dei cicli di sterilizzazione e diminuisce i consumi di acqua ISTANTANEOUS VAPORIZER outside the chamber allows higher sterilization speeds...

 Open the catalog to page 9
KALOSTERY AUTOCLAVES-10

catalogo fornetti Affidabilità e semplicità nella sterilizzazione professionale Reliability and semplicity all in one professional strarization system

 Open the catalog to page 10
KALOSTERY AUTOCLAVES-11

catalogo fornetti 1-10-2009 12:08 Pagina 11

 Open the catalog to page 11
KALOSTERY AUTOCLAVES-12

catalogo fornetti Vuoto termodinamico Controllato elettronicamente Termodynamic vacuum Using a high-performance Double-stage Vacuum pump pressione pressure COMPLETAMENTE AUTOMATICA gestita da microprocessore COMPLETELY AUTOMATIC controlled by microprocessor tempo time Grafico ciclo completo Kalostery N Complete graphic cycle Kalostery N 10

 Open the catalog to page 12
KALOSTERY AUTOCLAVES-13

catalogo fornetti CARATTERISTICHE FEATURES SISTEMA DI CHIUSURA semplice e pratico con doppia sicurezza CLOSURE SYSTEM easy and pratical with double safety CAMERA IN ACCIAIO INOX di grosso spessore, stampata in un unico pezzo STEINLESS STEEL CHAMBER single piece moulded steel DISPLAY A CRISTALLI LIQUIDI con continua visualizzazione della temperatura e della pressione LCD DISPLAY with continuous temperature and pressure display DOPPIO SENSORE di sicurezza sulla chiusura del portello DOUBLE SENSOR for safety on door closure DOPPIO CONTROLLO del processo di sterilizzazione DOUBLE CONTROL of sterilization...

 Open the catalog to page 13
KALOSTERY AUTOCLAVES-14

catalogo fornetti menù dei programmi programs menu Kalostery B lt 18-23 Materiale e Strumenti Materials and Istruments Programma Program Cavi delicati e inossidabili (imbustati) Delicate hollow and rustproof hollow (wrapped) cavi imbustati hollow wrapped minuti minutes Cavi inossidabili (imbustati) Rustproof hollow (wrapped) cavi imbustati hollow wrapped minuti minutes Solidi in gomma e solidi delicati (imbustati) Solide made of rubber and delicate solids (wrapped) solidi imbustati solid wrapped minuti minutes Solidi inossidabili (imbustati) Rustproof solid (wrapped) solidi imbustati solid wrapped...

 Open the catalog to page 14
KALOSTERY AUTOCLAVES-15

catalogo fornetti Tabelle dei cicli. Studiate per la perfetta sterilizzazione dei vari materiali, grazie alla combinazione di vuoto, temperatura ed asciugatura. Cycles tables. Designeds for perfect sterilizzation of various materials, thanks to the combination of vacuum, temperature and drying. Kalostery S lt 18-23 Materiale e Strumenti Materials and Istruments Programma Program Cavi delicati e inossidabili (imbustati) Delicate hollow and rustproof hollow (wrapped) cavi imbustati hollow wrapped minuti minutes Cavi inossidabili (imbustati) Rustproof hollow (wrapped) cavi imbustati hollow wrapped...

 Open the catalog to page 15
KALOSTERY AUTOCLAVES-16

catalogo fornetti Menù dei programmi Programs menu Kalostery N lt 18-23 Tempo Totale Total Time Materiale e Strumenti Materials and Istruments Programma Program Solidi in gomma e solidi delicati Solid made of rubber and delicate solid (wrapped drying) asciugatura lunga long dry minuti minutes Solidi in gomma e solidi metallici Solid made of rubber and solid metal (unwrapped) asciugatura corta short dry minuti minutes Solidi inossidabili Solid stainless steel and metal instruments (wrapped) asciugatura lunga long dry minuti minutes Solidi inossidabili Solid stainless steel and metal instruments...

 Open the catalog to page 16
KALOSTERY AUTOCLAVES-17

catalogo fornetti caratteristiche technical features KALOSTERY B Chiusura motorizzata Motor-operated closure Meccanico Mechanical Sicurezza blocco porta Door lock safety Elettrica Electrical Elettrica Electrical Meccanico Mechanical Frazionato Fractionated Pre e post vuoto Pre and post vacuum Termodinamico Thermodynamic Bowie & Dick / Helix / Vacuum Bowie & Dick / Helix / Vacuum test Bowie & Dick / Helix / Vacuum Tipo di vuoto Type of vacuum Vaporizzatore istantaneo Immediate steam generator Programmi test Test programs Stampante a bordo Onboard printer Grafico Graphic Grafico Graphic Ciclo notte...

 Open the catalog to page 17
KALOSTERY AUTOCLAVES-18

catalogo fornetti accessori - optionals accessories and optionals SIGILLATRICE TERMOSEAL ampia gamma di test per autoclave. Helix test per il controllo della sterilizzazione nei corpi cavi. Bowie & Dick Test per il controllo della sterilizzazione nei corpi porosi. Indicatori chimici per il controllo di ogni ciclo di sterilizzazione. Spore per il controllo biologico della sterilizzazione con design ergonomico e rapidi tempi di saldatura. Portarotoli a scomparsa. Sigillatura stirata di 12 mm. Dimensioni L480 x H198 X P85 mm Tensione 230V 50/60 Hz Potenza 100W - Peso 9 Kg demineralizzatore con controllo...

 Open the catalog to page 18

All Manfredi catalogs and technical brochures

  1. CATALOGUE

    32  Pages

  2. CONSUMABLE

    46  Pages

  3. NEW SMALLCAST

    2  Pages

  4. CLIMAKER

    1  Page

  5. FRESATECH

    1  Page

  6. SMALLCAST

    2  Pages

  7. PHOTOTRAY

    1  Page

  8. KERAPRESS

    2  Pages

  9. OL 463

    1  Page

  10. Fresa

    1  Page

  11. GALILEO

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.