CWP 100 RO System w/ Hot Water Loop Disinfection
2Pages

{{requestButtons}}

Catalog excerpts

CWP 100 RO System w/ Hot Water Loop Disinfection - 1

Competent, Consistent, & Compliant Medical Device Reverse Osmosis System 5,000 to 13,000 GPD The CWP 100 H offers cost-effective, consistent delivery of AAMI grade water standards according to ANSI/AAMI/ ISO 13959:2009, water for dialysis at the point of use. This system is designed to meet all current standards for dialysis quality water. The semi-automated heat disinfection of the distribution loop and the automated chemical disinfection of the RO and membranes simply and easily reduce biofilm development and minimizes levels of endotoxin, fungi, yeast and other microbial contaminants. Greater cost-effectiveness is ensured through system efficiency and labor savings. The CWP represents a simple, convenient, and effective disinfection strategy. Advanced electronics and top quality components also ensure quiet, reliable, and safe operation. Standard Features Optional Items Hot water loop disinfection Mar Cor Purification offers a complete line of components and Medical-grade Wirsbo-cleanPEX® distribution system accessories, including: Direct feed operation Blending Valves and Booster Pumps Semi-automated disinfection of the loop and RO membrane Multi-Media Filters Integrated end-to-end heat with the Phoenix® Hemodialysis System Water Softeners Carbon Adsorption Monitoring software for documentation and verification of disinfection procedures Hardness and Total Chlorine Test Kits 510(k)-cleared as a water purification system for hemodialysis ETL certified AAMI Water Analysis Chemical Disinfectants

Open the catalog to page 1
CWP 100 RO System w/ Hot Water Loop Disinfection - 2

Technical Data CWP 100 H Specifications Product Water - Minimum capacity at 20˚C and at a pure water outlet pressure of 29 psi(200 kPa) Model Part Number Product Water in gallons/min (l/min) Depends on inlet water quality. The system is designed to utilize drinking water that meets the standards of the Safe Drinking Water Act, 40 CFR. Additional pretreatment of inlet water is required. A properly maintained system using inlet water meeting SDWA can obtain the following rejection rates: Total dissolved salts > 95 % • Bacteria (CFU) & endotoxins > 99 % • Water conversion factor 67 % Water...

Open the catalog to page 2

All Mar Cor catalogs and technical brochures

  1. SDS

    4 Pages

  2. MINNCARE HD

    2 Pages

  3. Minncare

    2 Pages

  4. WRO 300 H

    2 Pages

  5. Millenium HX

    2 Pages

  6. BioPure HX2

    2 Pages

  7. CWP

    2 Pages

  8. f

    2 Pages