Product catalog summary
Overview: The 4400M Medical Series Reverse Osmosis (RO) System by Mar Cor Purification is designed for high-quality water production, easy installation, and straightforward control. It is FDA and Health Canada approved, meeting AAMI grade water standards.
Standard Features: The system includes a powder-coated steel frame, a high-efficiency pump, stainless steel housings, a digital controller, flow meters, pressure gauges, an automatic inlet shut-off valve, and a programmable auto-flush system. It is compatible with Minncare® Cold Sterilant disinfectant.
General Specifications: The system produces 4,000 to 24,000 gallons per day (GPD) at 77°F, with a recovery rate of 50-75%. It uses a thin film composite membrane and has a nominal rejection rate of 95-99% for ionic material.
Materials of Construction: Key materials include powder-coated steel for the frame, thin film polyamide for membrane elements, and stainless steel for membrane housing and high-pressure tubes.
Applications: The system is suitable for hemodialysis, clean sterilize reuse (CSR), sterile processing departments (SPD), and central laboratories.
Technical Data: Operating pressure is 250 PSIG, with a maximum recovery of 75%. The system operates within a temperature range of 2-35°C and requires a minimum inlet pressure of 30 PSIG.
Installation Considerations: Ensure 18 inches of space around the system for serviceability, install on a firm surface, and maintain a minimum dynamic operating pressure of 30 PSIG.
Feed Water Requirements: The system requires potable tap water with specific limits on silt density index, chlorine, total dissolved solids, and other parameters.
Contact Information: Mar Cor Purification has multiple locations worldwide, including Canada, the USA, the Netherlands, and Singapore, for customer support and service.
See more

Catalog excerpts

4400M RO System 4,000 to 24,000 GPD-1

Competent, Consistent, & Compliant Medical Device Reverse Osmosis System 60Hz 4,000 to 24,000 GPD Mar Cor Purification’s 4400M Medical Series RO Machines are designed for durable operation, high quality product water production, easy installation and straight-forward control. This 4400M Series have 510(k) clearance with the FDA as a class II and Health Canada as a class III medical device. It is designed and tested to meet AAMI grade water standards according to ANSI/AAMI/ISO 13959:2009 for RO product water. Standard Features • • • • • • • • • • • • Free standing powder coated steel frame Quiet, high efficiency pump and motor Quality tested spiral wound elements in stainless housings Low micron rated prefilter in opaque housing User-friendly digital controller with water quality readings & alarms Full range of flow meters and pressure gauges Automatic inlet shut-off valve Adjustable reject recirculation Programmable auto-flush system Permeate divert ensuring high quality product Clean-In-Place ports Compatible with 1% Minncare® Cold Sterilant disinfectant solution General Specifications • • • • • • • Production: 4,000 to 24,000 GPD @ 77°F (25°C) Recovery: 50-75% Motor Horsepower: 2.0 to 7.5, 3 Phase, 60HZ Element: Full Fit, Thin Film composite membrane, 4x40 Nominal Rejection: 95-99% of all ionic material Connections: 1/2-inch FNPT to 1-1/2-inch FNPT Materials: All critical wetted materials are stainless steel or inert plastic Frame: Powder Coated Steel Membrane Elements: Thin Film Polyamide Membrane Housing: 304 Stainless Steel Low Pressure Pipe: Schedule 80 PVC High Pressure Tube: 316L Stainless Steel Control Panel Enclosure: NEMA 4/12 Reverse Osmosis Pump: Stainless Steel Typical Medical Application • • • • Hemodialysis Clean Sterilize Reuse (CSR) Sterile Processing Department (SPD) Central Laboratory

 Open the catalog to page 1
4400M RO System 4,000 to 24,000 GPD-2

Technical Data 4400M 60 Hz Specifications @ 25°C Standard Systems Model Number Elements Number Non Standard Systems (Additional lead time will apply) Model Number Elements Number System Dimensions: 80.5” High x 38” Wide x 29” deep (All weights and dimensions are approximate). Example: 4400M-8K = 8,000 GPD Operating Parameters • • • • • • • Ordering Information Operating Pressure: 250 PSIG (1724 KPA) Maximum Recovery: 75% Nominal Rejection: 95-99% Operating Temperature: 2-35° C (35-95° F) Minimum Inlet Pressure: 30 PSIG (210 KPA)* Design Temperature: 25° C (77° F) Electrical Requirements: 208/3/60...

 Open the catalog to page 2

All Mar Cor catalogs and technical brochures

  1. SDS

    4  Pages

  2. MINNCARE HD

    2  Pages

  3. Minncare

    2  Pages

  4. WRO 300 H

    2  Pages

  5. Millenium HX

    2  Pages

  6. 23G Series RO

    2  Pages

  7. BioPure HX2

    2  Pages

  8. CWP

    2  Pages

  9. f

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.