TM3PD

TM3PD

TM3PD

Product catalog summary
Overview
The document describes the Delta TM3PD module, a pneumatic system designed for leak testing using the differential method. It is suitable for integration into automated systems and offers a range of features to enhance testing efficiency and accuracy.

Specifications
  • Leak testing capability up to 40 bar with a resolution of 0.1 Pa.
  • Differential full scale ranges from 10 to 50 mbar.
  • Power supply requirement is 24 Vdc with a maximum of 1 A.
  • Compressed air must be dry, non-condensing, 5-micron filtered, and oil-free, compliant with ISO8573-1.
  • Includes RS485 and USB communication interfaces with Modbus protocol.
  • Housing is made of unpainted aluminum.

Features
  • Fully integrated pneumatics and electronics for ease of use and installation.
  • Digital interface for PLC and communication interfaces for data management.
  • Capability to store up to 300 test tables.
  • Indicators include LEDs for test phases, pass, and fail status.
  • Programmable parameters and remote sensor calibration.

Accessories
  • Pressure and flow regulators, external vacuum generation module, air filters, and fixing brackets.
  • Staubli® connector for leak masters and dust caps included.

Software and Calibration
  • Software Manager for data collection, management, and backup of test tables.
  • HMI terminal with touchscreen display for managing multiple instruments.
  • Calibration service provided in compliance with ISO9001 standards, with scheduled verification against national or international test masters.

Applications
The Delta TM3PD is designed to be interfaced with traditional PLC systems, software managers, and HMI with dedicated software, making it a versatile solution for various industrial applications.
See more

Catalog excerpts

TM3PD-1

DeltaTM3PD MODULE FOR LEAK TEST WITH DIFFERENTIAL METHOD ON AUTOMATED SYSTEM • Leak test up to 40 bar • Resolution up to 0.1 Pa, differential full scale from 10 to 50 mbar • Fully integrated pneumatics and electronics • Test time reduced • Ease of use and installation • Digital interface for PLC • Communication Interfaces RS485 and USB • Up to 300 test tables DESCRIPTION The testing cycle is based on a comparison between the product being tested and a reference volume. In this way, the effects of the pressure settlement inside the tested product are reduced and the accuracy in detecting a leak rate is increased, achieving excellent results in a quicker testing time. TM3PD DELTA TM3PD pneumatic modules represent the blend of traditional leak test equipment and are the best solution to integrate a reliable and compact testing station into your automated system. DELTA TM3 can be interfaced with: • SOFTWARE MANAGER

 Open the catalog to page 1
TM3PD-2

SPECIFICATION Power Supply Dry, non-condensing, 5-micron filtered, and oil-free air, compliant with ISO8573-1, 6x4 mm hose fitting hose connection 4x2.5 / 6x4 / 8x6 mm Pilot pressure compatible with the instrument full scale Sensor Calibration Remote control software procedure Pressure Regulator External (option) 4 LEDs: two yellow (test phases), green (passed), red (failed) Test Counter PASSED and FAILED totals, resettable to zero Date and time, with supercap, 7 days back up max Programmable parameters Up to 300 testing tables, general testing parameters 2 photocoupled inputs: START / RESET...

 Open the catalog to page 2

All MARPOSS catalogs and technical brochures

  1. SOFTWARE

    2  Pages

  2. DOSASET

    2  Pages

  3. LTC

    2  Pages

  4. LEAK MASTER

    2  Pages

  5. TM3P

    2  Pages

  6. TM3PF

    2  Pages

  7. T3LPQ

    2  Pages

  8. T3LPF

    2  Pages

  9. T3LP

    2  Pages

  10. T3LMF

    2  Pages

  11. T3LD

    2  Pages

  12. T2

    2  Pages

  13. 2SEAL

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.