Catalog excerpts
Noninvasive and Continuous Hemoglobin (SpHb ) Monitoring ® Real-time visibility to changes – or lack of changes – in hemoglobin between invasive blood sampling The Radical-7® Pulse CO-Oximeter® and rainbow® adhesive sensors are indicated for the noninvasive and continuous monitoring of total hemoglobin concentration (SpHb), along with SpO2, pulse rate, and methemoglobin (SpMet®) – for use with adult, pediatric, and infant patients.
Open the catalog to page 1Limitations of Traditional Methods >> aboratory hemoglobin values are only available intermittently and are often delayed L >> linicians can estimate blood loss but this can both overstate and understate actual blood loss1,2 C When Considered with All Other Information, SpHb Monitoring Supports Patient-Centered Clinical Management In this surgical case, SpHb measurements were blinded to the clinicians. Between invasive blood sampling, the clinicians could not assess changes, or lack of changes, in hemoglobin levels.3 Step 1: Draw Blood Step 2: Label vial and send to lab Multiple steps in...
Open the catalog to page 2SpHb Monitoring Across the Continuum of Care © 2014 Masimo. All rights reserved. Monitoring hemoglobin continuously from Surgery to the PACU to the ICU and general floor. Upgradable rainbow SET Technology Platform ® Masimo rainbow SET is a noninvasive monitoring platform featuring Masimo SET Measure-through Motion and Low Perfusion™ pulse oximetry with the option to measure multiple additional blood constituents and physiologic parameters. ® >> xygen Saturation (SpO2) O >> Pulse Rate (PR) >> Perfusion Index (PI) > Total Hemoglobin (SpHb ) > Methemoglobin (SpMet ) > Oxygen Content (SpOC™) >...
Open the catalog to page 3All Masimo catalogs and technical brochures
-
Solutions for COVID-19
3 Pages
-
TNI softFlow® 50
2 Pages
-
Blue ® Sensor
2 Pages
-
RD SET ™
5 Pages
-
RD rainbow SET ™
2 Pages
-
Replica
2 Pages
-
Pronto
2 Pages
-
UniView ™
2 Pages
-
Kite ™
2 Pages
-
Eve™ CCHD
2 Pages
-
SafetyNet™
5 Pages
-
Rad-67™
2 Pages
-
Radius PPG™
2 Pages
-
Rad 5
2 Pages
-
Masimo Rad-57
2 Pages
-
Rad-97™ Pulse CO-Oximeter®
2 Pages
-
Radius-7
2 Pages
-
Radical-7
2 Pages
-
TIR-1™
2 Pages
-
NomoLine-O™
2 Pages
-
Masimo Trace™
3 Pages
-
Masimo Automation Platform
3 Pages
-
Root ®
15 Pages
-
Trauma Sensors
2 Pages
-
Newborn Sensors
2 Pages
-
RRa
2 Pages
-
MightySat Rx
3 Pages
-
EMMA Mainstream Capnometer
2 Pages
-
Iris Gateway
2 Pages
-
MX-5
1 Pages
-
Brain Function Monitoring
2 Pages
-
Root
2 Pages
-
Nomoline Airway Adapter Set
2 Pages
-
Nomoline Adapter
2 Pages
-
EMMA Capnograph
2 Pages
-
SpCO
2 Pages
-
E1 Ear Sensor
3 Pages
-
Masimo annual report
27 Pages
-
Masimo Rad-8
2 Pages
-
Pleth Variability Index
2 Pages
-
Total Hemoglobin Solutions
5 Pages
-
SpHb
2 Pages
Archived catalogs
-
E1® Ear snsor
2 Pages
-
MS-2013
1 Pages
-
SpMet ®
2 Pages
-
MS-2011
1 Pages