Catalog excerpts
A handheld pulse oximeter with Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry > In a study published in Journal of Clinical Anesthesiology comparing three pulse oximetry technologies, Masimo SET® demonstrated the highest sensitivity and specificity in identifying desaturation events during conditions of motion and low perfusion1 > Lightweight, handheld device with user-configurable power up default settings > Sleep Mode allows clinicians to disable audio tones and dim LEDs > Up to 72 hours of trending memory > Perfusion Index (Pi) is an assessment of the pulsatile strength at a specific monitoring site (e.g. the hand, finger, or foot), and as such Pi is an indirect and noninvasive measure of peripheral perfusion > Signal I.Q.® (SIQ) provides an assessment of the confidence in the displayed SpO2 value > FastSat® tracks rapid changes in arterial O2 > SmartTone beeps in sync with pulse, even under patient motion conditions > Sensitivity options: APOD®, Normal, and MAX > Audible and visual alarms for High/Low Saturation,Pulse Rate, Sensor Off, and Low Ba
Open the catalog to page 135 Signal I.Q. (SIQ) provides an assessment of 2 %SpO 30 25 1.75 the confidence in the displayed SpO2 value. A 20 1.5 1.25 vertical LED bar rises and falls with the15 pulse, 1 12 .5 where the height of the bar indicates the 9 .25 6 quality of the signal (left graphic). <.1 <3 3 35 Perfusion Index (Pi) is an assessment of the 30 25 pulsatile strength at a specific monitoring 20 site15(e.g. the hand, finger, or foot), and as such 12 Pi is9 an indirect and noninvasive measure of 6 peripheral perfusion. The LED bar is highest <3 and green when theSIQ quality of the perfused site is best; when...
Open the catalog to page 2All Masimo catalogs and technical brochures
-
Solutions for COVID-19
3 Pages
-
TNI softFlow® 50
2 Pages
-
Blue ® Sensor
2 Pages
-
RD SET ™
5 Pages
-
RD rainbow SET ™
2 Pages
-
Replica
2 Pages
-
Pronto
2 Pages
-
UniView ™
2 Pages
-
Kite ™
2 Pages
-
Eve™ CCHD
2 Pages
-
SafetyNet™
5 Pages
-
Rad-67™
2 Pages
-
Radius PPG™
2 Pages
-
Masimo Rad-57
2 Pages
-
Rad-97™ Pulse CO-Oximeter®
2 Pages
-
Radius-7
2 Pages
-
Radical-7
2 Pages
-
TIR-1™
2 Pages
-
NomoLine-O™
2 Pages
-
Masimo Trace™
3 Pages
-
Masimo Automation Platform
3 Pages
-
Root ®
15 Pages
-
Trauma Sensors
2 Pages
-
Newborn Sensors
2 Pages
-
RRa
2 Pages
-
MightySat Rx
3 Pages
-
EMMA Mainstream Capnometer
2 Pages
-
Iris Gateway
2 Pages
-
MX-5
1 Pages
-
Brain Function Monitoring
2 Pages
-
Root
2 Pages
-
Nomoline Airway Adapter Set
2 Pages
-
Nomoline Adapter
2 Pages
-
EMMA Capnograph
2 Pages
-
SpCO
2 Pages
-
E1 Ear Sensor
3 Pages
-
Masimo annual report
27 Pages
-
Masimo Rad-8
2 Pages
-
Pleth Variability Index
2 Pages
-
Total Hemoglobin Solutions
5 Pages
-
SpHb
2 Pages
Archived catalogs
-
E1® Ear snsor
2 Pages
-
MS-2013
1 Pages
-
SpMet ®
2 Pages
-
MS-2011
1 Pages