framework of 6063-T6 aluminum extrusions. All intersections are to be secured with aluminum angles and stainless steel flat head screws thick clear polycarbonate sheet. Plated spring hinges are used on both doors. Shims and all mounting hardware not included. STAINLESS STEEL CAT CONDO Product Specifications The units shall have an inner and outer shell of 20 gauge type 304 stainless steel and all interior box seams shall be welded or soldered to be watertight. The space between the shells shall be filled with fiberglass insulation. There shall be a formed 3/8” high debris and liquid retention lip across the front of each unit. The rear viewing window shall be 3/16” thick tempered glass. Gate grids shall be constructed of 304 stainless steel wire 3/16” in diameter in the vertical direction with 13/16” spacing between wires, and 304 stainless steel wire 5/16” in diameter in the horizontal direction and the perimeter wire with 11 1/2” or less spacing between wires. Horizontal and vertical wires shall be resistance welded at each juncture and each wire shall insert into the framework. Privacy doors shall be made of stainless steel and have 3/16” vertical wires with 13/16” spacing between wires welded to the sheet metal. The latches shall be 14 ga. Stainless Steel with a self latching mechanism and provision for a pad lock. The units shall have 5” dia. casters with brakes. Each unit shall two interior portal openings with stainless steel portal doors secured to the inner wall of the unit. Vertical sliding doors shall be one of the following materials (specify, #1, #2, #3): 1. 1/4” thick, low-stress translucent polypropylene. 2. 1/4” thick Polymetal 3. 0.100” thick Aluminum Channels shall be solid extruded aluminum 6063-T6. Doors are raised or lowered by pulling or releasing a 3/16” clear vinyl coated stainless steel wire cable that is secured to the top of the door. Kenl-Dors come equipped with cable, “S” hooks, pulleys, screw-eyes, and all necessary hardware for easy installation. Kenl-Dors® are available in three standard sizes: Regular – for openings up to 29” high by 12” wide. Large – for openings up to 29” high x 17” wide. Extra large – for openings up to 34” high x 17” wide. Other sizes available. Optional cable guards shall be made of 0.100” aluminum sheet and shall be fastened to the channels with stainless steel screws. Insulated Kenl-Dor® Vertical sliding doors shall be 1/4” thick, low-stress translucent polypropylene. Each door shall have an 18 gauge (.048”) aluminum cover. The cover shall be held in place with stainless steel barrel bolts and screws. The interior space of the aluminum cover shall be filled with .5” thick EPS (expanded polystyrene foam) with an R value of 2.085. Channels shall be solid extruded aluminum 6063-T6. Doors are raised or lowered by pulling or releasing a 3/16” clear vinyl coated stainless steel wire cable that is secured to the top of the door. Kenl-Dors come equipped with cable, “S” hooks, pulleys, screw-eyes, and all necessary hardware for easy installation. Weather baffles (see spec. for Weather Baffle) are included with each Insulated Kenl-Dor®. Dog-Bone Counterweight Outer shell shall be made of high density polyethylene. Each counterweight shall have a threaded steel insert molded in to the upper end to accommodate a supplied 3/8” galvanized steel eyebolt. Shot shall be securely contained inside the outer shell to reach the desired weight Weather Baffle Weather baffles shall be constructed of .050” aluminum sheet. Each sheet shall have a full length white plastic living hinge. The hinge shall be attached to the aluminum with double bond by ½” wide tape 25 mil thick. Weather baffles shall be provided with all necessary hardware for installation. Pickwick® Dog-Operated Door Outside frame shall be 5/16” thick solid cast aluminum, swinging door shall be 1/4” Specifications listed were in effect at time of publication. Mason Company reserves the right to modify or discontinue designs, materials, equipment or prices without obligation or notice. Copyright © 2011 Mason Company an additional end blocker consisting of a strip of closed cell neoprene foam with 3M VHB double sided tape on one side. Chain Link Dividers and Back Panels Framework Aluminum Framed FRP Swing-Up Rest Bench Bench surface shall be constructed of .030” FRP or High Pressure Wilsonart Laminate bonded on each side of a .400” HDPE substrate. The outer framework of the bench shall consist of 6063-T6 aluminum extrusions. All intersections are to be secured with aluminum angles and stainless steel flat head screws. The vertical front debris guard shall consist of 1’ grid polyethylene structural foam 7/16” thick and run the width of the bench. The debris guard shall be connected to the bottom of the bench with stainless steel bolts and nuts. Bench shall be designed to pivot up and remain in the upright position until it is manually released and lowered. Bench shall be provided with all necessary hardware for installation. Tubular Frame Rest Bench Frame and legs shall be made from 1.05” O. D. Gatorshield® tubing. Resting area shall be made from ABS plastic .250” thick and fastened by aluminum keyhole clamps with stainless steel screws. All corners shall be precision welded, ground, cleaned, and covered with a zinc-rich coating containing at least 80% pure zinc when dried. A polypropylene plug shall be inserted in each leg. Standard sizes are regular 18” x 36” x 6”, large 24” x 36” x 6”, and extra large 24” x 48” x 6”. Special sizes available. Specify free-standing or swing-up design. Fabric Swing-Up Rest Bench The outer framework of the bench shall consist of 6063-T6 aluminum extrusions. All intersections are to be TIG welded. The fabric is to be 40 oz. solid vinyl with plastic rod heat sealed into the edges. The fabric shall be secured to the outer frame with locking channels consisting of 6063-T6 aluminum extrusions and are attached to the outer frame with stainless steel bolts and stainless steel Nyloc nuts. The vertical front debris guard shall consist of 1’ grid polyethylene structural foam 7/16” thick, and shall be connected to the bottom of the bench with stainless steel bolts and nuts. Bench shall be designed to pivot up and remain in the upright position until it is manually released and lowered. Bench shall be provided with all necessary hardware for installation. Aluminum Gutter Covers Gutter covers shall be constructed of .100” aluminum sheet. Each cover shall have two rubber floor pads mounted to the return flange of the cover, hardware shall be stainless steel. Retainer pendants shall be constructed of 14 gauge (.075”) stainless steel. Offset mounting brackets shall be 14 gauge (.075”) hot dipped galvanized steel. Gutter covers shall be provided with all necessary hardware for installation. Stainless Steel Bowl Insert Insert shall be constructed of 1/4” diameter stainless steel wire. Inserts shall be secured in place with stainless steel screws. Bowl wires shall be MIG welded at all intersections. The bowl shall be retained in the insert by a swing down door that shall be made of 16 gauge (.060”) stainless steel. The swing down door shall be held in the closed position by means of a stainless steel swing pendant made of 12 gauge (.105”) stainless steel. Pendant shall be mounted to the enclosure with a stainless steel screw, Nyloc nut, and a nylon spacer. PLASTISOL RAISED FLOORS Flooring shall be plastisol-coated expanded metal or woven wire in custom-sized flat sheeting or with welded legs (up to 3” high). Coating material shall be 94 Durometer Shore A Plastisol with a uniform coating thickness of 1/8”. Coating shall contain a fungicide bacteria growth inhibitor. Hole size after coating shall be: Diamond pattern: 7/16” x 3/4”; 1/2” x 1”; or 3/4” x 1-1/2” Woven wire oblong: 7/16” x 2” Sales and Design Assistance Available Mason’s staff of sales consultants, customer service representatives, and designer-drafters will be happy to provide information or assistance as needed, including (without charge or obligation) design advice, specification information, computer drawings, and price quotations to help you plan the annual enclosure systems in your project. Contact us! Product Specifications DIVIDERS AND BACK PANELS All Stainless Steel Isolation Panels Perimeter frame and internal bracing shall consist of 1” x 16 gauge (.065” wall) square 304 A-554 welded stainless steel tubing with 180 grit polish. Each corner of the frame shall be TIG welded. Wire grids shall be constructed of 304 stainless steel wire 1/8” in diameter in the vertical direction with 1 5/8” spacing between wires, and 304 stainless steel wire 1/4” in diameter in the horizontal direction with 6” or less spacing between wires. Horizontal and vertical wires shall be resistance welded at each juncture. Sheet metal cover on each side to be 20 ga. (.036”) 304 stainless steel with 180 grit polish. Between the sheet metal covers is a core material of 1” thick EPS (expanded polystyrene) sheet. Panel to floor seal mounting angles and panel corner vertical connection angles to be 16 ga. (.060”) 304 stainless steel. Aluminum Framed FRP Isolation Panels Panels shall be constructed of an outer framework of 6063-T52 aluminum U-channel 3/4” x 3/4” x 1/8” thick. Internal braces shall be 6061-T6 aluminum H-channels 1-1/2” x 3/4” x 1/8” thick. Bottom portion of isolation panel shall be one of the following materials (specify #1, #2, #3): 1. 030” FRP bonded on each side of a .400” HDPE substrate (specify height). Solid panels to be perimeter sealed to the aluminum framework (specify height). 2. High pressure Wilsonart® laminate bonded on each side of a .400” HDPE substrate (specify height). Solid panels to be perimeter sealed to the aluminum framework (specify height). 3. 24 gauge (.024”) 304 stainless steel sheet bonded on each side of a.400” HDPE substrate (specify height). Solid panels to be perimeter sealed to the aluminum framework (specify height). Upper portion shall be one of the following materials (specify #1, #2, #3, #4): 1. 1” grid polyethylene structural foam 7/16” thick (specify height). 2. Hot dipped galvanized welded wire. Wire panels shall be welded at each juncture and shall consist of 1/8” diameter vertical wires with 1 1/2” spacing between wires and 1/4” diameter horizontal wires with 4 1/4” spacing between wires. Wire panels shall be contained by means of a semi-rigid PVC extrusion inset into the aluminum framework. 3. Stainless steel welded wire. Wire panels shall be welded at each juncture and shall consist of 1/8” diameter vertical wires with 1 1/2” spacing between wires and 1/4” diameter horizontal wires with 4 1/4” spacing between wires. Wire panels shall be contained by means of a semi-rigid PVC extrusion inset into the aluminum framework. 4. Glass panels shall be 1/4” tempered glass held in place by a semi-rigid PVC extrusion inset into the aluminum framework. Sani-Slope™ Aluminum Sloped Floor Mounting Available on Aluminum Framed Isolation Panels Only Patented T-flange shall be made of solid extruded 6061-T6 aluminum. T-flange shall be 2-1/2” wide at its base and shall extend upward to a height of at least 3”. Patented isolation panel bottom rail extrusion shall be made of solid 6061- T6 extruded aluminum and shall be dimensioned to fit over the T-flange so that the isolation panel can be leveled and secured. T-flange shall be sealed to the floor with provided silicone sealant. Silvis Seal™ (Available on Aluminium Framed FRP Isolation Panels) Patent pending Silvis Seals shall be a co-extrusion consisting of a rigid vinyl base and two flexible polyvinyl chloride (PVC) sealing ribs. Adhered to the top of the co-extrusion shall be two strips of 3M VHB double sided tape. Each seal shall have Shall be made from Gatorshield® ASTM A500 structural grade steel tubing, 1.050” pipe size O.D.; 0.94 pounds per foot weight (± 5%), 50,000 p.s.i. minimum yield strength. Lightweight tubing or galvanized schedule 40 pipe not permitted. The exterior surface shall be in line, hot-dip galvanized in molten zinc (zinc conforming to ASTM B-6) to a nominal weight of 0.8 ounces per square foot of surface as measured by the methods of ASTM A90. Additionally, the tubing shall be coated with a chromate rust inhibitor and a clear polymeric top coat. The interior tubing surface shall be completely and evenly coated with a full zinc-based galvanizing compound to assure maximum corrosion-resistant integrity. The resulting product will exhibit corrosion resistance at least 3 times (300%) greater than galvanized schedule 40 pipe (ASTM A-53-8) when tested in accordance with ASTM B117 standards. All corners on the frames shall be precision welded, ground, cleaned and given two zinc-rich coatings containing at least 95% pure zinc when dried and a single top coat of silver Rustoleum®. Panels installed on graded floors shall be manufactured to follow the slope. Example: if taper in floor is 1-1/2” over 6’ span, slope equals 1/4” per lineal foot of panel. Fabric & Mesh Fabric shall be woven from smooth-seal galvanized zinc wire, either (#9, #11, or #13) gauge. The zinc coating shall be a minimum of 1.2 ounces of pure zinc per square foot of wire surface in accordance with ASTM A-641-91. All fabric shall be manufactured undersized by 1/4” to be fitted in the tubular frame. Fabric shall be stretched taut to the inside of the centerline of the frame under tension and shall be laced with #13 gauge wire at each intersection to the frame so that it remains tight. There shall be tie wires secured to all vertical braces. There shall be a uniform diamond square mesh of (2”, 1-1/2”, 1-1/4” or 1”) between the parallel sides after weaving. All fabric ends shall be knuckled for safety. Isolation Panels Upper chain link and bottom solid portions shall be separated by a horizontal brace made from (1.050” or .815”) O.D. tubing. Bottom portion of isolation panel shall be 48” high (other heights available), shall be installed with 3/4” wide keyhole clamps spaced on 8” center and shall be one of the following materials (specify #1, #2, or #3): 1. Stainless steel sheets of #24 gauge (18-8 type 304-2B) shall be installed with #22 gauge stainless steel keyhole clips and spot-welded. 2. Galvanized steel sheets of #24 gauge shall be installed with #22 gauge stainless steel keyhole clips and spot welded. 3. ABS Sheet (Acrylonitrile Butadiene Styrene) 1/8” thick shall be installed with aluminum keyhole clamps and stainless steel bolts. Recommended for indoor use only. 4. FRP sheets of .030” FRP bonded on each side of a .400” HDPE substrate (specify height) in an outer framework of 6063-T52 aluminum U-channel 3/4” x 3/4” x 1/8” thick. Solid panels to be perimeter sealed to the aluminum framework Isolation channel shall be extruded 6063-T5 aluminum. Two panel hangers shall be provided for channels up to 10’ long. Three panel hangers are used for panels over 10’ long. Channels shall be secured and sealed to the floor with provided silicone sealant. GATES AND STALL FRONTS Tempered Glass Gate Outer framework and latch consists of same as Stainless Steel Gate Unit. Glass panels shall be 1/4” tempered glass held in place by a semi-rigid PVC extrusion inset into the aluminum framework of 6063-T52 aluminum U-channel 3/4” x 3/4” x 1/8” thick. Panels shall be secured to the frame by means of stainless steel fasteners. Stainless Steel Gates and Stall Fronts Gate and stall front frames shall consist of 1” x 16 gauge (.065” wall) square 304 A-554 welded stainless steel tubing with 180 grit polish. Each corner of the frame shall be TIG welded.
Open the catalog to page 12 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
1 Page
1 Page
8 Pages
1 Page
4 Pages
2 Pages
2 Pages
2 Pages
8 Pages
1 Page
4 Pages
2 Pages