S1000 - 1

Infection Control Steam sterilizers Matachana S1000

Open the catalog to page 1
S1000 - 2

S1000 steam sterilizers The evolution of a success MATACHANA Series S1000 Sterilizers have been designed taking into account the real needs of today's hospital sterilization, as much in sterilization centrals as in surgical units, outpatient centres, outsourced sterilization services, etc. The S1000 is designed and manufactured in our production site in Barcelona (Spain), a new plant equipped with the latest technological breakthroughs in terms of sustainability, energy efficiency and process control. (*) S1000 has version with built-in steam generator as well as without steam generator to...

Open the catalog to page 2
S1000 - 3

Steam sterilizers S1000 Series General features of series S1000 • Technology New control system more powerful and modern. TFT touch screen for loading area with integrated PLC. Frontal made of an innovative material that prevents dirt and reflections. Easy to clean. • Ergonomics More accessible displays with a modern and versatile interface. • Sustainability Energy and water consumption reduced thanks to incorporated economizer systems. • Efficiency Redesigning of vacuum system by Venturi. • Compatibility Perfect drying tested with the most demanding packaging on the market. • Connectivity...

Open the catalog to page 3
S1000 - 4

With this sterilizers' new line MATACHANA aims to create and develop equipment with an easy and intuitive use while offering a high level of quality. Hence the incorporation of a control unit composed mainly by a TFT colour touch panel QVGA (with integrated PLC) for the loading area, a 4 lines characters LCD display with function keys for the unloading area and an industrial PLC. Navigation menu MATACHANA has developed an intuitive interface with a number of icons that allows the user of the sterilizer to move easily and quickly through different programs selection menus and configuration....

Open the catalog to page 4
S1000 - 5

Print functions The sterilizer includes a thermal printer that allows the operator or the maintenance technician to receive information about the equipment status and cycle progress. Additionally, the large internal screen memory enables to connect an external printer via Ethernet port, for printing cycles in A4 format. It makes it more manageable and, in addition to the report's texts, allows a pressure and temperature graph of the cycle. Furthermore, the system downloads cycles through a USB port in the sterilizer frontal, offering the operator the possibility to file and keep the...

Open the catalog to page 5
S1000 - 6

Programs MATACHANA Series S1000 sterilizers have several pre-set programs covering an extensive range of combinations to suit the needs of the most demanding sterilization centrals. Two types of programs are available: • Test programs: checking correct sterilizer operation • roduction programs: sterilization or production programs of sterile material P Graph (Pressure profile) of a production cycle: Pressure [hPa] S1000 standard programs Production programs For packed materials (solid instruments or with cavities) For packed thermosensitive materials For packed materials (solid instruments...

Open the catalog to page 6
S1000 - 7

Options • EasyCHECK. Integrated electronic B&D test • Built-in compressor • Vacuum system with liquid ring pump • Connection to recovery systems and external cooling, allowing considerable savings in water consumption • Manual and automatic steam bypass • Record and graphic display by a 3, 4 or 5 channels video recorder • Data download via USB port • Printout report and cycle graph in A4 format by external printer • Supply by UPS • Able to perform maintenance on left side • Remote alarm • Air detector (manual and automatic version) • Automatic generator purge • Front panel in stainless...

Open the catalog to page 7
S1000 - 8

Series S1000 main features Compact design Its size allows placing it in tight spaces and benefits the installation greatly. Continuous chamber and jacket in stainless steel High quality 1.4404 (AISI-316L). Compact design Enveloping design jacket No “cold spots” in the chamber guaranteed. Frame in high quality steel Vertical sliding doors Through pneumatic cylinder with security and stop systems. Conditioning of doors (double door models) to ensure that the door from the sterile area can be opened ONLY if the cycle has been successfully completed. High precision mechanized of the door gasket...

Open the catalog to page 8
S1000 - 9

Stainless steel circuits Steam sterilizers S1000 Series Chamber and steam manometers on the loading frontal panel and chamber on the unloading side frontal panel. Control panel composed by a TFT colour touch screen (loading side) and LCD display with function keys (unloading side). Frontal service door Manufactured with an innovative material that prevents the accumulation of dirt and reflections. Easy to clean. Steam generator made of 1.4404 stainless steel (AISI316L) with automatic operation. Smart control system consisting of: - Adjustment of the working pressure according to the...

Open the catalog to page 9
S1000 - 10

Loading systems and complementary elements MATACHANA provides a wide range of loading complements whose top priority is to facilitate the work in the preparation area and subsequent loading / unloading into the sterilizer. Loading platform Each one of these complementary elements is adapted to different models of S1000 sterilizers as well as to different needs the final user may have. • Modular basket in stainless steel 1.4301 (AISI-304) • Loading platforms in stainless steel 1.4301 (AISI-304) rod With temperature resistant wheels and caps. • Loading frame in stainless steel 1.4301...

Open the catalog to page 10
S1000 - 11

Steam sterilizers S1000 Series • Loading/unloading trolleys at a fixed height in stainless steel 1.4301 (AISI-304) With different compatible fixing systems, depending on the guides system installed in the sterilizer. High manoeuvrability due to the wheels with locking and brake system. Trolley at fixed height • Loading/unloading trolleys with electric platform height adjustment Facilitates the task in areas with sterilizers of different heights. High manoeuvrability due to the wheels with locking and brake system. • Loading/unloading trolley with electrically adjustable height platform...