Overview: OMNIPORE® Surgical Implants are sterile, single-use implants made from porous high-density polyethylene, designed for reconstructive and aesthetic surgery. They are provided by Matrix Surgical USA and should not be used if the packaging is compromised. The implants are available in various anatomical configurations for craniomaxillofacial reconstruction and augmentation.
Company Background: Matrix Surgical USA, founded in 2012 in Atlanta, Georgia, specializes in medical devices, particularly porous high-density polyethylene craniofacial implants. The company collaborates with surgeons globally to develop innovative solutions for complex clinical challenges.
Mission and Values: The company aims to exceed industry standards in product quality and performance, support healthcare practitioners in achieving optimal patient outcomes, and maintain a commitment to innovation and corporate citizenship.
Implant Handling Techniques: OMNIPORE implants should be handled with aseptic techniques. They can be cut and shaped using surgical instruments, and stabilization can be achieved with sutures or screws. Implants should be soaked in hot saline for contouring and cooled for stabilization.
Product Specifications: OMNIPORE implants are characterized by their large pore sizes and high porosity, allowing for tissue ingrowth. They are available in preformed shapes for various facial augmentations and reconstructions, including chin, malar, and mandibular onlays.
Design Y™ Implants: Developed with Dr. Michael J. Yaremchuk, these implants include mandible onlays, chin implants, and malars, designed for precise and symmetric augmentation. They are available in multiple sizes and configurations to meet patient-specific needs.
Additional Products: The document also details two-piece chin designs, osteotomy gap implants, and nasal sheets for specific reconstructive needs.
Usage and Precautions: Surgeons are advised to follow proper surgical techniques and consult product labeling for detailed instructions. Implants are not cleared for market in every country, and Matrix Surgical USA should be consulted for marketing clearance information.
Paranasal Shapes: Crescent-shaped implants are designed for augmentation of the piriform aperture, available in right and left orientations and two sizes. Petite and large options are specified with dimensions.
Microtia Reconstruction: OMNIPORE Ear Implants offer flexibility for shaping the helix, requiring coverage with a vascular flap and skin graft. Suitable for congenital and traumatic repairs, with specific dimensions for ear base and helical rim implants.
BENDBLOCK™ TF2 Implant: Designed for temporal region augmentation post-trauma, available in various sizes and orientations, with pedicles for volume enhancement.
Temporal Hollowing: Pterional Implant corrects temporal hollowing defects, smaller than BENDBLOCK TF2, with screw fixation capability.
Cranial Reconstruction: Includes Craniotomy Gap Wedge, Burr Hole Covers, OMNIPORE Blocks, BENDBLOCK Implant, Cranial Grid Implant, Cranial Hemisphere, Sellar Buttress Implant, and Occipital Implant, each with specific applications and dimensions.
Orbital Volume Replacement and Enophthalmus Correction: OMNIPORE Spheres and Enophthalmos Wedges are used for ocular procedures, with dimensions provided for various sizes.
Orbital Floor Repair: OMNIPORE Sheets and DUROMAX Orbital Implants are used for craniofacial reconstruction, with features like radiographic visibility and anatomical shape.
Terms and Conditions: Details on ordering, delivery, and return policies, including conditions for returns and restocking charges.
See more

Catalog excerpts

OMNIPORE® SURGICAL IMPLANT-1

OMNIPORE SURGICAL IMPLANT ® Porous High-Density Polyethylene Implants For Reconstructive and Aesthetic Surgery

 Open the catalog to page 1
OMNIPORE® SURGICAL IMPLANT-2

OMNIPORE® Surgical Implants are provided sterile by Matrix Surgical USA. DO NOT USE any implant if the package is open, damaged or wet. All STERILE items are considered single use and cannot be re-sterilized. Surgeons should consult the package insert for instructions on the proper use and precautions for any OMNIPORE Surgical Implants prior to use. For additional information worldwide, please contact your local OMNIPORE Surgical Implants Distributor; in the U.S., please contact Matrix Surgical USA directly using the information below. Distributors should consult their distributor agreements...

 Open the catalog to page 2
OMNIPORE® SURGICAL IMPLANT-3

Matrix Surgical USA About Us Matrix Surgical USA was founded in 2012 as a privately held company based in Atlanta, Georgia, USA. The company’s core management team has deep domain expertise in the medical device industry and extensive experience with the design, development, production, marketing and global distribution of porous high-density polyethylene craniofacial implants. Matrix Surgical USA’s flagship product is OMNIPORE®, a biocompatible form of porous high-density polyethylene. The company offers more than 95 unique SKUs of various anatomical configurations and dimensions for reconstruction...

 Open the catalog to page 3
OMNIPORE® SURGICAL IMPLANT-4

OMNIPORE® Surgical Implant Handling Techniques Implant Preparation OMNIPORE Surgical Implants and OMNIPORE® DUROMAX® Orbital Implants are sold sterile and should never be re-sterilized. Prior to handling the implants, operating room personnel should put on a clean pair of powder free gloves. Keep the implant in its protective packaging until time of implantation. Upon opening the inner pouch, the implant should be placed in a solution of clean sterile physiologic saline and antibiotics of the surgeon’s preference. Strict adherence to the principles of aseptic technique should be followed with...

 Open the catalog to page 4
OMNIPORE® SURGICAL IMPLANT-5

OMNIPORE Surgical Implants ® OMNIPORE implants are manufactured from a linear form of high-density polyethylene. Polyethylene has a long history of use in surgical implants. OMNIPORE Surgical Implants allow for tissue ingrowth because of its interconnecting open pore structure. The firm nature of the material allows carving with a sharp instrument without collapsing the pore structure. OMNIPORE Surgical Implants in blocks, sheets and preformed anatomical shapes are intended for augmentation and restoration of the craniomaxillofacial skeleton. The porosity of OMNIPORE Surgical Implants is maintained...

 Open the catalog to page 5
OMNIPORE® SURGICAL IMPLANT-6

Design Y™ Facial Reconstruction and Cosmetic Implants Design Y™ Mandible Onlays* Designed in conjunction with Michael J. Yaremchuk, M.D. Design Y Mandible Onlays benefit patients who have skeleton mandibular deficiencies or surgically altered anatomy. Implant design provides the opportunity for augmentation of ramus height and ramus width. It also provides the opportunity to alter the inclination of the mandibular plane and restore continuity of the mandibular border. The registration tab allows for ideal and symmetric placement. Three sizes with left and right orientation allow the surgeon to...

 Open the catalog to page 6
OMNIPORE® SURGICAL IMPLANT-7

Design Y™ Facial Reconstruction and Cosmetic Implants Design Y™ Malars* Designed in conjunction with Michael J. Yaremchuk, M.D. Design Y Malars are used to reproduce normal contours of the facial skeleton. The Design Y Malar implants are uniquely designed with registration tabs which allow ideal and symmetric placement. Implants augment the projection of the malar prominence and extend from the infraorbital foramen, medially, to the zygomatico-temporal suture, laterally. They can be easily trimmed and contoured with a scalpel to meet specific patient requirements. Malars are available in a variety...

 Open the catalog to page 7
OMNIPORE® SURGICAL IMPLANT-8

Facial Reconstruction and Cosmetic Implants Two-Piece Chin Designs The Two-Piece Chin implant comes in two pieces: a right half and a left half. Segmentation facilitates easy placement of the implant. Designed for the reconstruction of the retrusive or hypoplastic chin, the two-piece design also provides flexibility and proper anatomical positioning of the implant. Implants are available in several anterior projections. Osteotomy Gap Implant The Osteotomy Gap Implant is designed to correct the inferior border contour irregularities of the mandible which inevitably occur after sagittal split osteotomy...

 Open the catalog to page 8
OMNIPORE® SURGICAL IMPLANT-9

Nasal Reconstruction Nasal Sheet The Nasal Sheet is used to support tip elevation when nasal tip projection is needed. The Sheet is placed between the Medial Crura of the alar cartilage. Meticulous surgical technique should be used to prevent the implant from extending above the alar cartilage into the tip area. Paranasal Shapes Crescent-shaped Paranasal Implants are designed to augment both the lateral and the inferior aspects of the pirform aperture. Implants can be carved to allow selective augmentation. The implants are available with right and left orientation and are available in two sizes....

 Open the catalog to page 9
OMNIPORE® SURGICAL IMPLANT-10

NEW JRTM Ear Base* Designed in conjunction with John Reinisch, M.D. The JRTM Ear Base implants offer maximum flexibility and provide the surgeon with an attractive alternative from the variable results obtained with cartilage grafts traditionally used in ear reconstruction. The two-piece design of the JR Ear Base combined with the Helical Rim allows for tailoring the height and projection of the helix. The surgeon should always cover the entire implant with a vascular flap (i.e., temporal parietal fascia flap) followed by a skin graft to prevent late exposure of the implant. JR Ear Base implants...

 Open the catalog to page 10
OMNIPORE® SURGICAL IMPLANT-11

Temporal Hollowing Pterional Implant The Pterional Implant is used to correct temporal hollowing defects in patients who have had temporalis muscle atrophy due to surgical interventions through a pterional approach to the brain. The implant is placed deep to the temporalis when closing and can be secured with screw fixation to the surrounding temporal bone. Available in one size and left and right orientation, the Pterional Implant is smaller than the BENDBLOCK TF2 Implant, although similar in design. BENDBLOCK™ TF2 Implant The BENDBLOCK TF2 Implant is designed to augment deficient soft tissue...

 Open the catalog to page 11

All Matrix Surgical USA catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.