Amplifiers and stimulators
9Pages

{{requestButtons}}

Catalog excerpts

Amplifiers and stimulators - 1

amplifiers stimulators Comprehensive solution for in vitro pharmacology/physiology experiments.

Open the catalog to page 1
Amplifiers and stimulators - 2

amplifiers stimulators to ensure the smooth operation of our systems, we offer reliable amplifiers for measuring force, pressure, temperature, and action potentials. all amplifiers are equipped with analog output and fixed-value calibration signals to enhance their flexibility for use with different daq systems. to broaden the range of scientific areas where our solution can be applied, we also offer reliable stimulator electronics to better serve our clients. while all electronics can be used standalone, we recommend consulting with us regarding the intended usage and desired setup to...

Open the catalog to page 2
Amplifiers and stimulators - 3

amplifiers stimulators |'| III =. exp-sg The analog amplifiers are available in one-, two-, three-, and four-channel designs, developed to receive and amplify signals from a force transducer with low noise and a high filtration level. It has a fixed 1 mV calibration signal for easier calibration to any DAQ system. A factory-calibrated force transducer is available for each channel. The amplifier can be customized to amplify signals from any analog force transducer. In case of any unique needs about force transducers, please consult our colleagues about the available options. Amplification:...

Open the catalog to page 3
Amplifiers and stimulators - 4

amplifiers stimulators The analog amplifiers are available in one-, two-, three-, and four-channel designs, suitable for 0.1ºC accuracy in continuous temperature measurement of gaseous, liquid, and solid substances, depending on the connected sensor. It has a fixed 450 mV calibration signal for easier calibration to any DAQ system. A wide range of factory-calibrated temperature sensors is available for each channel. In case of any unique needs about the temperature sensors, please consult our colleagues for a custom-made solution. Measurement range: Accuracy: Display: Built in Calibration...

Open the catalog to page 4
Amplifiers and stimulators - 5

amplifiers stimulators The analog amplifier is produced in one-, two-, three-, and four-channel designs, specifically designed to record the standard (I-II-III) ECG signal. It has a fixed 1 mV calibration signal for easier calibration to any DAQ system. The low-noise design, high-pass notch filter, and input diode defibrillator protection make the measurement convenient for any species used in biological experiments (mouse, rat, dog, pig, etc.). There is a wide range of factory-calibrated patient cables for ECG measurement on different species. The amplifier can be customized to amplify...

Open the catalog to page 5
Amplifiers and stimulators - 6

amplifiers stimulators Ml ||l z. exp-mfe In terms of technical solutions, this amplifier goes beyond being a nine-channel multiplexed low-noise amplifier, it is a monophasic ECG amplifier equipped with an Einthoven bridge. Each channel includes a fixed 1 mV calibration signal for easy calibration to any DAQ system. With this electronics, a scientist can record ECG signals from an isolated heart in any DAQ system. Various factory-calibrated sensors are available for measurements on different subjects. The amplifier can be customized to amplify signals from any analog ECG patient cable or...

Open the catalog to page 6
Amplifiers and stimulators - 7

amplifiers stimulators I'l III =. exp-st EXP-ST square wave stimulators are produced in one-, two-, and four-channel designs. The devices share identical stimulus impulse and performance parameters. They are available with or without isolation from the electrical grid. A wide range of stimulation electrodes is available. In case of any unique needs about the stimulation electrodes, please consult our colleagues for a custom-made solution. The MCU controlling unit is integrated into the same rack with the one- or two-channel designs and supplied separately for the four-channel design. EXP-ST...

Open the catalog to page 7
Amplifiers and stimulators - 8

amplifiers stimulators The aim of the WS-DA WORKSTATION is to offer an easy-to-use solution for running our dedicated data acquisition software, namely SPEL Haemosys for cardiovascular experiments and SPEL Isosys for acquiring data from contraction measurements. The unit comprises a computer with essential peripherals (monitor, keyboard, and mouse) and a built-in Analog-Digital converter for the data acquisition software.

Open the catalog to page 8
Amplifiers and stimulators - 9

info@mdegmbh.eu www.mdegmbh.eu MDE GmbH- Schwanthaler str. 5. 80336 Munchen, Germany Podmaniczky Street 87, 1064 Budapest, Hungary