insert_setting

insert_setting

insert_setting

Product catalog summary

Overview

This document provides detailed technical specifications and recommended power settings for various piezosurgery inserts used in dental and medical surgical procedures. It covers multiple categories of inserts, their intended applications, and the appropriate power modes to ensure optimal performance and safety.

1. Insert Categories and Functions

  • Implant Preparation (IM): Inserts designed for implant site preparation, including special bone types and sizes (e.g., IM1S special, IM2A, IM3P-15).
  • Osteotomy (OT): Inserts for cutting or shaping bone, suitable for cancellous (spongy) and cortical bone, with some special variants (e.g., OT1, OT7S-3 special).
  • Osteoplasty (OP): Inserts for bone remodeling and shaping, including periosteal and special root periosteum applications (e.g., OP1, OP5A special).
  • Mini Implant Preparation (MDI): Smaller implants preparation inserts (e.g., MDI 1.9, MDI 2.5).
  • Sinus Membrane Elevation (EL): Inserts specialized for sinus membrane procedures (e.g., EL1 endo*, EL3 endo*).
  • Periosteum (PR): Inserts for periosteum-related procedures on cancellous and cortical bone.
  • Endodontic Retrograde (EN): Inserts for root canal and retrograde endodontic treatments (e.g., EN1 endo*, EN5R endo*).
  • Extraction (EX): Inserts for tooth extraction involving bone (e.g., EX1, EX3).
  • Explantation (EXP): Special inserts for implant removal, including left and right variants (e.g., EXP3-R special).
  • Perio (PP, PS): Inserts for periodontal treatments.
  • Implant Cleaning (ICP, IC1): Inserts for cleaning implants and root surfaces.
  • Restorative (DB2): Inserts for restorative dental procedures.

2. Power Settings and Modes

The document specifies maximum power permitted for each insert type and provides detailed power mode recommendations. Power levels are generally categorized as:

  • 1 = Maximum power
  • 2 = Medium power
  • 3 = Minimum power

Power modes include:

  • Bone (BONE): Standard mode for cancellous and cortical bone.
  • Bone Special (BONE SPECIAL): For specialized bone applications requiring adjusted power.
  • Root Perio (ROOT PERIO): For periodontal root treatments.
  • Endo (ENDO): For endodontic procedures.
  • Boosted C (BOOSTED C): Enhanced power mode for more demanding cutting or preparation tasks.
  • High (HIGH): Higher power settings for specific periosteal or cleaning tasks.
  • Low (LOW): Lower power settings for delicate procedures such as sinus membrane elevation or endodontic retrograde.

3. Key Recommendations and Best Practices

  • Use the specified power mode and level for each insert to avoid damage to tissue or instrument.
  • Special inserts marked with an asterisk (*) require particular attention to power settings, often using special or boosted modes.
  • For implant preparation and osteotomy, power settings typically range from 1 to 3 depending on bone density and procedure complexity.
  • Sinus membrane elevation and endodontic procedures require low power settings to minimize risk to delicate tissues.
  • Explantation inserts have reversed power level recommendations (3 to 1) to ensure controlled removal.
  • Always refer to the multilingual guidance for correct instrument settings to ensure safety and efficacy.

4. Multilingual Notes

The document includes power setting instructions in multiple languages (Italian, German, Spanish, French, Swedish, English) emphasizing the importance of correct insert settings for optimal surgical outcomes.

5. Document Version and Identification

Revision: 04
Document code: 02 15 00 71
Date: 20-01-2017

Summary

This technical document serves as a comprehensive guide for selecting and setting power levels on piezosurgery inserts across a wide range of dental surgical applications. It ensures practitioners apply the correct power modes to maximize efficiency, safety, and clinical success.

See more

Catalog excerpts

insert_setting-1

Û Settaggi appropriati per gli inserti Û Appropriate settings for the inserts Û Korrekte Einstellungen für die Instrumente Û Réglages appropriés pour les inserts Û Ajustes apropiados para los insertos Û Korrekta Inställningar för spetsarna special* implant implant implant implant implant implant implant implant implant implant implant implant implant implant implant implant implant implant cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical special* special* cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical special* cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical cancellous / cortical perio perio / special perio * Massima potenza consentita * Maximum power permitted * Maximal zugelassene Leistung * Puissance maximum autorisée perio cancellous / cortical perio / special cancellous / cortical cancellous / cortical MINI IMPLANT PREP MDI 1.9 MDI 2.2 MDI 2.5 implant implant implant SINUS MEMBRANE ELEVATION EL1 endo* EL2 endo* EL3 endo* SLS special* SLE1 special* SLE2 special* PERIOSTEUM PR1 PR2 cancellous / cortical cancellous / cortical endo* endo* endo* endo* endo* endo* endo* endo* cancellous / cortical cancellous / cortical cancellous / cortical special / cancellous / cortical special / cancellous / cortical special / cancellous / cortical special / cancellous / cortical perio perio perio perio perio perio perio endo / perio * Máxima potencia permitida * Maximalt tillåten effekt perio / special 02150071 Piezosurgery insert setting Rev. 04 20-01-2017

 Open the catalog to page 1
insert_setting-2

Û Settaggi appropriati per gli inserti Û Appropriate settings for the inserts Û Korrekte Einstellungen für die Instrumente Û Réglages appropriés pour les inserts Û Ajustes apropiados para los insertos Û Korrekta Inställningar för spetsarna MODE POWER IMPLANT PREP IM1S BONE IM1 AL IMPL IM1 SP IMPL IM2A IMPL IM2A-15 IMPL IM2P IMPL IM2P-15 IMPL IM2.8A IMPL IM2.8P IMPL IM3A IMPL IM3A -15 IMPL IM3P IMPL IM3P-15 IMPL IM3.4A IMPL IM3.4P IMPL IM4A IMPL IM4P IMPL P2-3 IMPL P3-4 IMPL SPECIAL* IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT IMPLANT...

 Open the catalog to page 2
insert_setting-3

Û Settaggi appropriati per gli inserti Û Appropriate settings for the inserts Û Korrekte Einstellungen für die Instrumente Û Réglages appropriés pour les inserts Û Ajustes apropiados para los insertos Û Korrekta Inställningar för spetsarna MODE POWER** IMPLANT PREP IM1S BONE IM1 AL BONE IM1 SP BONE IM2A BONE IM2A-15 BONE IM2P BONE IM2P-15 BONE IM2.8A BONE IM2.8P BONE IM3A BONE IM3A -15 BONE IM3P BONE IM3P-15 BONE IM3.4A BONE IM3.4P BONE IM4A BONE IM4P BONE P2-3 BONE P3-4 BONE OSTEOTOMY OT1 BONE OT1A BONE OT2 BONE OT3 BONE OT4 BONE OT5 BONE OT5A BONE OT5B BONE OT6 BONE OT7 BONE OT7A BONE OT7S-3...

 Open the catalog to page 3
insert_setting-4

Û Settaggi appropriati per gli inserti Û Appropriate settings for the inserts Û Korrekte Einstellungen für die Instrumente Û Réglages appropriés pour les inserts Û Ajustes apropiados para los insertos Û Korrekta Inställningar för spetsarna IMPLANT PREP IM1S BOOSTED IM1 AL BOOSTED IM1 SP BOOSTED IM2A BOOSTED IM2A-15 BOOSTED IM2P BOOSTED IM2P-15 BOOSTED IM2.8A BOOSTED IM2.8P BOOSTED IM3A BOOSTED IM3A -15 BOOSTED IM3P BOOSTED IM3P-15 BOOSTED IM3.4A BOOSTED IM3.4P BOOSTED IM4A BOOSTED IM4P BOOSTED P2-3 BOOSTED P3-4 BOOSTED OSTEOTOMY OT1 BOOSTED OT1A BOOSTED OT2 BOOSTED OT3 BOOSTED OT4 BOOSTED OT5...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.