Group: MedLinket
Catalog excerpts
Clinical Significance EtCO2 monitoring has great application value and significance to the clinical. EtCO2 monitoring device is a quite valuable alarming system with timely, accurate detection of some incidents and severe combinations to avoid the occurrence of severe hypoxia injury. It can dramatically improve the safety of surgery and anesthesia, which not only benefits the patients, but protects the safety of the clinical personnel themselves. 1. External: American Society of Anesthesiologists (ASA) requires that all the patients under anesthesia should be set for EtCO2 and SpO2 monitoring. 2. Internal: the partial pressure of EtCO2 has been considered as another basic vital sign besides body temperature, respiratory rate, heart rate, blood pressure, electrocardiogram, and arterial oxygen saturation. Product Advantages Lightweight, soft cannulas with a curved design fit the contours of the face to minimize pressure Split-flow cannula design reduces gas mixing, facilitating accurate EtCO2 measurements EtCO2 Sensor & Accessories Product Introduction Application Field Medlinket provides a cost-effective EtCO2 monitoring 1. Monitoring the patient’s respiratory status; program for clinical practice. It is plug-in and play. 2. Assists in determining when to intubate or extubate; Advanced non-spectrophotometric infrared technology 3. Verification of ET tube placement; can be used to measure the instantaneous CO2 4. Alerts if accidental extubation occurs; concentration, respiratory rate, end-tidal CO2 value and 5. Ventilator disconnect detection; inspired CO2 concentration of the measured object. 6. Verification of ventilation during transport. Unique membrane tube penetration drying technology to ensure moisture removal and protection of equipment Compated with low humidity sampling lines, it can effectively prolong the use time of sampling lines (≤120h) Compatible NomoLine (ISA) CO2 Sidestream Gas Analyzer Modules
Open the catalog to page 1Masimo ^SM, Zoll Philips ^iJM, Mindray (China) SIS marketing@med-linket.com Compatible Philips ^f'JM Mindray (China) Compatible Brand Philips OEM #: M2533 Mindray OEM #: 0010-10-42671 Philips OEM #: M2516 M2536A Mindray OEM #: 0010-10-42664 Single patient use airway adapter, Adult Single patient use airway adapter, Pediatric EtC02 External Sidestream Module Accessories Single patient use CO2 Nasal sample cannula Adult, 2m Single patient use CO2 Nasal sample cannula Pediatirc, 3m Single patient use CO2 Nasal sample cannula with dryer, Adult, 2m Single patient use CO2 Nasal sample cannula...
Open the catalog to page 2Compatible Oridion, Mindray (China) SIS Philips ^iJM www.med-linket.com marketing@med-linket.com [S) Compatible Compatible Brand LH: Low Humidity or Short-term; HH: High Humidity or Long-term Compatible Brand LH: Low Humidity or Short-term; HH: High Humidity or Long-term
Open the catalog to page 3Compatible Mindray (China) SIS, GE Drager ComenBiolight ^^f#, Philips ^iJM www.med-linket.com marketing@med-linket.com Compatible Brand/Models Water Trap Series Price Code Compatible Mindray (China) SIS For BeneView, iPM, iMEC, PM, MEC-2000 series monitors, PM-9000/7000/6000 series, BeneHeart defibrillator Transducer Type Principle of Operation Dryline water trap, Adult/Pediatirc for dual-slot module Dryline water trap, Neonatal for dual-slot module Initialization Time Sidestream CO2 module and Mainstream CO2 sensor Non-dispersive infrared (NDIR) Capnogram displayed in less than 20 seconds;...
Open the catalog to page 4All Med-link Electronics Tech catalogs and technical brochures
-
V0014AL
2 Pages
-
186-0106,186-0200,M1174413
2 Pages
-
VE008BNA
2 Pages
-
VA002BNI
3 Pages
-
2 ECG Trunk Cables
5 Pages
-
V0015-C0243I
2 Pages
-
W0026E,W0045E,W0138C
2 Pages
-
W0001F,W0101F,W0001F
1 Pages
-
5198333
1 Pages
-
X0104B, x0110d
7 Pages
-
Y000R05, Y00005
2 Pages
-
X0046A
2 Pages
-
A02, A16
3 Pages
-
YA54A11-10, YA29A06-08
3 Pages
-
M1673A, EE026S6A, END405P3A
2 Pages
-
503180262, S0568OX-L
5 Pages
-
S0076J-L
5 Pages
-
B143
2 Pages
-
PE0001, PE0002
1 Pages
-
Y002A1-A06, Y001A1-A06
1 Pages
-
Fukuda Denshi
7 Pages
-
V0014A-C0234I
2 Pages
-
503180262, 503210262
20 Pages
-
HB03-522
4 Pages
-
END405P3A
2 Pages
-
V0014-C0243A
2 Pages
-
W0138C
2 Pages
-
Y000C1
1 Pages
-
Y000DT1
1 Pages
-
W0001F
2 Pages
-
S0010M-L-T
2 Pages
-
160100 series, M3718A
1 Pages
-
Y00005
1 Pages
-
P-050-050
1 Pages
-
287-P
1 Pages
-
G5018A
2 Pages
-
V0014C/P
1 Pages
-
Y00005
1 Pages
-
S0010J-S-T
2 Pages
-
Disposable ECG electrodes
4 Pages