Group: MedLinket
Catalog excerpts
Med-link can provide disposable ECG electrodes with prefabricated leads. It is suitable for different people and compatible with various brands of monitoring equipment in the hospital.
Open the catalog to page 1★ Single use packaging ensures longer storage cycle, avoiding cross-infection; ★ Pre-wired ECG electrodes can collect the ECG signals of patients quickly in emergency, severe and anesthesia operation, and improve clinical work efficiency and the rate of successful rescue; ★ Peelable ribbon cable design prevents lead wire entanglement and can be customized to fit any patient's body size; ★ Double-layer fully shielded leadwires design, especially suitable for ECG monitoring in anesthesia Operation; ★ Special adhesive conductive gel and AgCl sensors with excellent signals are easily bonded to...
Open the catalog to page 2Disposable ECG electrodes www.med-linket.com Avoiding cross-infection Double-layer Fully Shielded Leadwires Design Better anti-interference performance can improve signal to noise ratio ( SNR). Peelable Ribbon Cable Design Prevents lead wire entanglement and can be customized to fit any patient's body size.
Open the catalog to page 3The first listed company of monitoring consumables in China; Focus on monitoring consumables for 18 years; All products have purchased product liability insurance and social liability insurance; Exported to 117 countries, used by 2000+ terminal hospitals; 68 licensed patents. Mainstream brand ECG trunk cables Philips Compatible Mindray Compatible Mainstream brand instrument connector For Drager VISTA 120 monitor For Datex Ohmeda monitor For Nihon Kohden monitor For Drager Gamma XL monitor Shenzhen Med-link Electronics Tech Co.,Ltd Address: 2th, 4th and 5th Floor, Building Two, Hualian...
Open the catalog to page 4All Med-link Electronics Tech catalogs and technical brochures
-
V0014AL
2 Pages
-
186-0106,186-0200,M1174413
2 Pages
-
VE008BNA
2 Pages
-
VA002BNI
3 Pages
-
2 ECG Trunk Cables
5 Pages
-
V0015-C0243I
2 Pages
-
W0026E,W0045E,W0138C
2 Pages
-
W0001F,W0101F,W0001F
1 Pages
-
5198333
1 Pages
-
X0104B, x0110d
7 Pages
-
Y000R05, Y00005
2 Pages
-
X0046A
2 Pages
-
A02, A16
3 Pages
-
YA54A11-10, YA29A06-08
3 Pages
-
M1673A, EE026S6A, END405P3A
2 Pages
-
503180262, S0568OX-L
5 Pages
-
S0076J-L
5 Pages
-
B143
2 Pages
-
PE0001, PE0002
1 Pages
-
Y002A1-A06, Y001A1-A06
1 Pages
-
Fukuda Denshi
7 Pages
-
V0014A-C0234I
2 Pages
-
503180262, 503210262
20 Pages
-
HB03-522
4 Pages
-
END405P3A
2 Pages
-
V0014-C0243A
2 Pages
-
W0138C
2 Pages
-
Y000C1
1 Pages
-
Y000DT1
1 Pages
-
W0001F
2 Pages
-
S0010M-L-T
2 Pages
-
160100 series, M3718A
1 Pages
-
Y00005
1 Pages
-
P-050-050
1 Pages
-
287-P
1 Pages
-
G5018A
2 Pages
-
V0014C/P
1 Pages
-
Y00005
1 Pages
-
S0010J-S-T
2 Pages