Over-temp. Protection SpO2 Sensor
3Pages

{{requestButtons}}

Catalog excerpts

Over-temp. Protection SpO2 Sensor - 1

Indicator light The SpO2 sensor is equipped with a temperature sensor. After being Please read the instructions carefully before use, and use the product according to the instructions; matched with dedicated adapter cable and monitor, it has a partial 2 When the skin temperature of the patient's over-temperature monitoring function, which reduces the risk of burns monitoring site exceeds 41℃, the sensor will stop and reduces the burden of regular inspections by medical personnel. working immediately. At the same time, the The following conditions may be at risk of skin burns: indicator light of the SpO2 sensor adapter cable 1) The patient's measurement site has weak perfusion and cannot take emits a red light, and the monitor emits an alarm away the sensor temperature through normal blood circulation; sound, which prompts medical personnel to take 2) The measurement site is too thick; (for example, the foot of newborns timely measures to avoid burns; 3 When the skin temperature drops below 41℃, the whose weight are more than 3.5KG are too thick and should not be wrapped for measurement) sensor will restart to monitor SpO2. 3) Failure to regularly check the sensor and change the position. Over-temp. Protection SpO2 Sensor Product Advantages 1. Over-temperature monitoring: there is a temperature sensor at the probe end. over-temperature monitoring function, reducing the risk of burns and reducing the burden of regular inspections by medical personnel; 4. Internal Cardiovascular Dept. permeability; 3. Efficient and convenient: v-shaped probe design, quick positioning of the monitoring position; connector handle design, easier connection; 4. Safety guarantee: good biocompatibility, no latex; 5. High accuracy: evaluation of SpO 2 accuracy by comparing arterial blood gas analyzers; 6. Good compatibility: it can be adapted to mainstream brand monitors, such as avoid cross-infection. ④ Non-woven Fabric ⑤ Non-woven Fabric 5. Cardiothoracic Surgery Dept. (National Medical Products Administration) Products can be supplied for US market. Philips, GE, Mindray, etc; 7. Clean, safe and hygienic: production and packaging in the clean workshop to After matching with a dedicated adapter cable and monitor, it has a partial 2. More comfortable: the smaller space of the probe wrapping part and good air Sensor Categories ① Comfort Foam Non-Adhesive Speciality for getting and transfer

Open the catalog to page 1
Over-temp. Protection SpO2 Sensor - 2

Order Information Figures Registration Number Order Information Patient Size Order Code Characteristic Export to EUR & USA Price Code Covidien-Nellcor, Masimo, Philips, GE, Mindray, Spacelabs Recommended Dept.: operating room, ICU, emergency Dept. and other clinical Dept. Non-woven Fabric Non-woven Fabric Elastic Fabric Adult Neonatal Elastic Fabric Adult Pediatric Infant Neonatal Comfort Foam Non-Adhesive Compatible Models Recommended Dept.: Neonatology, anesthesia room, ICU Adult Pediatric Infant Neonatal Comfort Foam Non-Adhesive Single patient 24pcs/box V0/box repeated use Note: Please...

Open the catalog to page 2
Over-temp. Protection SpO2 Sensor - 3

Order Information Compatible Models Order Information Instrument Connector Yoke Connector (Sensor Side) Order Code Masimo: Rad-5, Rad-8 Datascope, Medtronic,Welch Allyn, Zoll, GE Healthcare (Must be Masimo Module) Nellcor: N-10, N-100, N-180, N-190, N-20, N-200, N-30, N-3000, N-390, N-395, N-6000, NPB-190, NPB-195, NPB-290, NPB-295, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, Symphony N-3000 BCI: 3100 series Advisor, Autocorr, etc. Draeger: Infinity/SC series, etc. GE Healthcare: Pro Series, Dash Series, Eagle /Solar Series etc. Datascope: Accutorr Series, DPM Series,...

Open the catalog to page 3

All Med-link Electronics Tech catalogs and technical brochures

  1. V0014AL

    2 Pages

  2. VE008BNA

    2 Pages

  3. VA002BNI

    3 Pages

  4. V0015-C0243I

    2 Pages

  5. 5198333

    1 Pages

  6. X0046A

    2 Pages

  7. A02, A16

    3 Pages

  8. S0076J-L

    5 Pages

  9. B143

    2 Pages

  10. HB03-522

    4 Pages

  11. END405P3A

    2 Pages

  12. V0014-C0243A

    2 Pages

  13. W0138C

    2 Pages

  14. Y000C1

    1 Pages

  15. Y000DT1

    1 Pages

  16. W0001F

    2 Pages

  17. S0010M-L-T

    2 Pages

  18. Y00005

    1 Pages

  19. P-050-050

    1 Pages

  20. 287-P

    1 Pages

  21. G5018A

    2 Pages

  22. V0014C/P

    1 Pages

  23. Y00005

    1 Pages

  24. S0010J-S-T

    2 Pages