S0010M-L-T
2Pages

{{requestButtons}}

Catalog excerpts

S0010M-L-T - 1

Patient monitor Med-linket SpO2 adapter cable Compatible brand technology modules and corresponding plug types 2 Disposable pulse oximeter probe The accuracy of the probe can be better demonstrated by clinical validation of SpO2 with a reference blood Sensor type Type Transparent airpermeable film (adhesive sensor) Transparent airpermeable film (adhesive sensor) Elastic nonwoven fabric (adhesive sensor) Elastic nonwoven fabric (adhesive sensor) Comfort foam (Non-adhesive sensor) Neonatal foot, or infant toe or Adult and pediatric finger Neonatal foot, infant toe, adult and pediatric finger, the wrap belt use soft sponges and velcro, which enhances the comfort and repeatability for single patient. gas analyzer! Medlinket's blood oxygen probe is matched with blood oxygen technology of various monitors in clinical practice,indicating that the accuracy meets the requirements of NMPA\FDA\CE standards. Sensor picture and material The YY 0784-2010 and ISO 80601-2-61 standards indicate that the blood oxygen simulator cannot verify the accuracy of the probe. [1] YY 0784-2010/ISO 9919: 2005 Medical electrical equipment Medical pulse oximeter equipment, basic safety and main performance special requirements, 2012-06-01 implement; [2] ISO 80601-2-61 Medical electrical equipment-Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment Second edition 2017-12. Application site Index or other finger

Open the catalog to page 1
S0010M-L-T - 2

Clinical test result Product advantages The wavelength of the light source and the parameters of the detector are optimized through experimental design to adapt to the thickness, skin color, gender, and age of different measurement parts, so as to ensure the accuracy and wider application range; Breathable material makes the patient more comfortable and reduces the impact of sweat on the sensor; Built-in good anti-light interference material can maintain accuracy even in sunlight; The unique sensor positioning design avoids the measurement error and burn risk caused by the serious deviation...

Open the catalog to page 2

All Med-link Electronics Tech catalogs and technical brochures

  1. V0014AL

    2 Pages

  2. VE008BNA

    2 Pages

  3. VA002BNI

    3 Pages

  4. V0015-C0243I

    2 Pages

  5. 5198333

    1 Pages

  6. X0046A

    2 Pages

  7. A02, A16

    3 Pages

  8. S0076J-L

    5 Pages

  9. B143

    2 Pages

  10. HB03-522

    4 Pages

  11. END405P3A

    2 Pages

  12. V0014-C0243A

    2 Pages

  13. W0138C

    2 Pages

  14. Y000C1

    1 Pages

  15. Y000DT1

    1 Pages

  16. W0001F

    2 Pages

  17. Y00005

    1 Pages

  18. P-050-050

    1 Pages

  19. 287-P

    1 Pages

  20. G5018A

    2 Pages

  21. V0014C/P

    1 Pages

  22. Y00005

    1 Pages

  23. S0010J-S-T

    2 Pages