GMK Revision System leaflet
1 / 2Pages

Catalog excerpts

GMK Revision System leaflet - 1

DIFFER EN T NEEDS... YOUR G L OB AL SOL UT I ON SOLUTIONS FOR EVERY SCENARIO An accurate and reproducible surgical technique is essential to address the unique clinical situation of each patient. Despite meticulous pre-operative planning, demanding surgical scenarios may require flexibility in intra-operative adjustments. VARIOUS LEVELS OF CONSTRAINT AVAILABLE The same femoral articular profile allows for full compatibility with GMK Primary inserts thus providing various levels of incremental constraint: ultra-congruent, posterior stabilised and semi-constrained. Modular instruments and modular implants have the potential to deliver this intraoperative flexibility. MINIMISE COMPLEXITY, MAXIMISE VERSATILITY The GMK Revision System has been designed with a clear goal: minimize complexity, maximize versatility. SAME INTERNAL FEMORAL PROFILE ACROSS ALL GMK SYSTEM IMPLANTS allows for a full transition through the system, providing incremental constraint according to each patient’s need. BONE PRESERVING ■ The GMK Revison and GMK Hinge femoral components are bone preserving, requiring minimal condylar resections and a reduced intercondylar box. gmk revision ■ GMK Revision and GMK Hinge has the same tibial keel length as GMK Primary and GMK Sphere. SAME INSTRUMENTATION FOR GMK REVISION AND GMK HINGE WITH IMPLANT-SPECIFIC TRIAL TRAYS to make it easy to switch intra-operatively to a more constrained implant. gmk revision specific trays general revision trays gmk hinge specific trays 360° OFFSET ■ On the tibial side, in combination with the asymmetric tibial baseplate, the offset option helps obtain uncompromised coverage of the tibial plateau profile. ■ On the femoral side, the offset option helps optimise the position of the implant relative to the intramedullary canal to accurately restore anterior flange location and flexion gap balance. COMPREHENSIVE RANGE OF SIZES AND OPTIONS ■ Cemented and cementless extension stems, interchangeable between tibia and femur, are available to address different patient needs and surgeon preferences. ■ Augmentation blocks, interchangeable between medial and lateral side, are available both for tibia and femur to address asymmetrical bone defects. ■ Various thicknesses are available for tibial inserts and tibial/ femoral augments to restore the appropriate joint line.

Open the catalog to page 1
GMK Revision System leaflet - 2

COMPLEX CASES MANAGED WITH MYKNEE ACCURACY C ROS S OVER PATIE NT M AT C H ED TE CHN OL OG Y I N KNEE REPLACEMEN T DIFFERENT NEEDS...YOUR GLOBAL SOLUTION 3D RECOSTRUCTION CT or MRI scan acquisition and bone model reconstruction. PRE-OPERATIVE PLANNING MyKnee planning performed in accordance with surgeon’s preferences to perform implant size assessment. STEM EVALUATION Estimation of stem positioning alongside tibia and femoral intramedullary canals. GMK Revision System. CUTTING BLOCK PRODUCTION MyKnee cutting blocks match exactly the surgeon’s pre-operative planning. They are based on...

Open the catalog to page 2

All Medacta catalogs and technical brochures

  1. SMS leaflet

    3 Pages