
Catalog excerpts

REDEFINING THR: THE AMIS SYNERGY The anterior approach, consolidated by years of clinical experience, is the only technique that follows an intermuscular and internervous path and therefore lowers the risk of damaging periarticular structures such as muscles, tendons, vessels and nerves. UNDERSTANDING TRADITION, MASTERING INNOVATION Medacta International is the world leader for educating and supporting surgeons in their pursuit of Anterior Minimally Invasive Surgery (AMIS). Reference Centers and Learning Centers around the world provide the necessary AMIS education experience and Medacta offers continuous support for surgeons, as well as constantly improving and developing the industry’s most specialised instrumentation platform. When you use the Masterloc Hip System, you enter the Medacta International world of AMIS. • The definitive MIS approach: AMIS. • Dedicated AMIS instrumentation. • The AMIS Mobile Leg Positioner: the original extension table included as part of the instrumentation, which makes surgery easier and reproducible. AMIS Education Programme based Medacta’s proven educational methods. The AMIS Mobile Leg Positioner will be supplied as part of the instrumentation to help ensure effective and reliable positioning of the leg during surgery. Traction, adduction and hyperextension have never been so easy. Brochure Joint REFERENCES [1] Healy W, Tilzey J, Lorio R, Specht L, Sharma S. Prospective, Randomized Comparison of Cobalt-Chrome and Titanium Trilock Femoral Stems. J Arthroplasty. 2009;24:831-6. [2] Parvizi J, Keisu K, Hozack W, Sharkey P, Rothman R. Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty. 2004 Feb;19(2):151-6. [3] McLaughlin J, Lee K. Total hip arthroplasty with an uncemented tapered femoral component. J Bone Joint Surg Am. 2008 Jun;90(6):1290-6. [4] Khan W, Muntimadugu E, Jaffe M, Domb AJ (2014). Implantable Medical Devices In W Khan and AJ Domb, Focal Controlled Drug Delivery (p. 33-59). Springer New York Heidelberg Dordrecht London. [5] Friction testing of the Mpact and Versafitcup coating samples. Data on file Medacta. [6] P. Robotti, A. Sabbioni, L. Glass, B. George, Macroporous Titanium Coatings , by Thermal Plasma Spray, ITSC 2013, International Thermal Spray Conference, May 13 –15, 2013,Busan, Korea. [7] J. E. Biemond et al, In vivo Assessment of Bone Ingrowth Potential of 3-Dimensional E-Beam Produced Implant Surfaces and the Effect of Additional Treatments by Acid-Etching and Hydroxyapatite Coating, J. Biomat. Appl, published on line January 27, 2011, 0885328210391495. [8] R. Ferro de Godoy et al., In vivo Evaluation of Titanium Macro-Porous Structures Manufactured Through an Innovative Powder Metallurgy Approach. Proceedings eCM XIII: Bone Fixation, Repair & Regeneration, June 24–26, 2012, Davos, Switzerland. [9] A. Goodship et al, In-vivo Assessment of the Ingrowth Potential of Engineered Surface Topographies Produced by Spark Plasma Sintering, Proceedings 9th World Biomaterial Congress, June 1-5, 2012, Chengdu, China. [10] McLaughlin JR, Lee KR. Cementless total hip replacement using second-generation components: a 12- to 16-year follow-up. J Bone Joint Surg Br. 2010 Dec;92(12):1636-41. All trademarks and registered trademarks are the property of their respective owners. Not intended for the U.S. market. Medacta International Strada Regina - 6874 Castel San Pietro - Switzerland Phone +41 91 696 60 60 - Fax + 41 91 696 60 66 Info@medacta.ch - www.medacta.com Masterloc Leaflet ref: 99.73.11 rev.02 Last update: July 2019
Open the catalog to page 1
TA P E R E D W E D G E F E M O R A L S T E M MASTERLOC HIP SYSTEM: UNDERSTANDING TRADITION, MASTERING INNOVATION TECHNICAL DETAILS The concept of tapered wedge femoral stems has been shown to provide excellent implant stability in short-term, mid-term and long-term clinical studies[1,2,3]. The MasterLoc Hip System follows this philosophy, utilizing a proprietary proximal coating - MectaGrip, designed for initial stability and long-term fixation. It was designed to provide for a definitive set of femoral offset options, completely independent from the leg length, helping to achieve good...
Open the catalog to page 2All Medacta catalogs and technical brochures
-
PowerSuture leaflet
2 Pages
-
PowerKnot leaflet
2 Pages
-
MectaQTH leaflet
2 Pages
-
FairFix leaflet
2 Pages
-
M-ARS ACL leaflet
2 Pages
-
Adult Scoliosis Patient brochure
24 Pages
-
M.U.S.T. SI Patient leaflet
8 Pages
-
MySpine MC Patient brochure
12 Pages
-
Sterile Implants leaflet
10 Pages
-
M.U.S.T. leaflet
2 Pages
-
M.U.S.T. MIS leaflet
2 Pages
-
M.U.S.T. Mini leaflet
2 Pages
-
MectaLIF leaflet
2 Pages
-
MectaLIF Anterior leaflet
2 Pages
-
MectaLIF TIPEEK leaflet
2 Pages
-
Mecta-C leaflet
2 Pages
-
Mecta-C Stand Alone leaflet
4 Pages
-
MySpine S2AI leaflet
4 Pages
-
MySpine MC leaflet
2 Pages
-
MySpine leaflet
2 Pages
-
HIGHCROSS leaflet
2 Pages
-
GASTON leaflet
2 Pages
-
MYHIP leaflet
2 Pages
-
M-VIZION leaflet
5 Pages
-
MPACT System leaflet
2 Pages
-
VERSAFITCUP CC TRIO leaflet
2 Pages
-
MINIMAX leaflet
2 Pages
-
SMS leaflet
3 Pages
-
QUADRA System leaflet
2 Pages
-
QUADRA-P System leaflet
4 Pages
-
AMISTEM System leaflet
2 Pages
-
AMISTEM-P leaflet
2 Pages
-
AMIS EXPERIENCE brochure
28 Pages
-
MYSHOULDER patient leaflet
8 Pages
-
MYSHOULDER leaflet
4 Pages
-
MOTO Medial patient leaflet
8 Pages
-
GMK Sphere patient leaflet
8 Pages
-
MyKnee patient leaflet
16 Pages
-
Efficiency KneePack flyer
2 Pages
-
GMK Revision System leaflet
2 Pages
-
MOTO MEDIAL leaflet
4 Pages
-
GMK UNI Anatomic leaflet
2 Pages
-
GMK Efficiency leaflet
2 Pages
-
MyKnee leaflet
4 Pages
-
GMK Primary leaflet
2 Pages
-
GMK Sphere leaflet
3 Pages