Overview: The brochure presents the Medacta Shoulder System, highlighting its complete, convertible, and innovative design. It emphasizes the system's adaptability to various anatomical and pathological conditions through a wide range of sizes and configurations.
MectaGrip Technology: This technology is used for proximal fixation in standard and short stems, enhancing metaphyseal fixation with hydroxyapatite.
Stemless Metaphysis: The system offers six sizes to accommodate different humerus anatomies, facilitating anatomical reconstruction.
Enhanced Design: The fins are optimized to reduce interference with the bicipital groove and maximize primary fixation. A 3D metal structure promotes bone adhesion and growth.
Humeral Diaphysis: The design and size range are optimized for initial stability using the MyBody platform. There are four length options and 11 diameter sizes for a true press-fit.
Anatomic Metaphysis: Offers true anatomical reconstruction with three angle options and tuberosity restoration. It is convertible for reverse configurations.
Anatomic Glenoid: Made of highly cross-linked polyethylene, it provides immediate stability with a barbed central post and peripheral pegs.
Double Eccenter & Humeral Head: Features double eccentricity for adjustable offset and a wide size range to restore correct anatomy.
SensiTiN Option: A ceramic-like coating that reduces metal ion release by up to 90%, available for both anatomic and reverse shoulder replacements.
Reverse Humeral Metaphysis & Liner: The semi-inlay design prevents excessive distalization and lateralization, with options for neck shaft angle to increase ROM or stability.
Glenoid Baseplate: Offers pegged and threaded fixation options with extensive size ranges and hydroxyapatite coating.
Glenosphere: Available in multiple sizes and lateralization options, with a fixed inferior offset to reduce scapular notching.
Conclusion: The Medacta Shoulder System provides a modular solution with extensive options for anatomical and reverse configurations, aiming to replicate native anatomy and improve patient outcomes.
See more

Catalog excerpts

MEDACTA SHOULDER SYSTEM leaflet-1

COMPLETE, CONVERTIBLE, INNOVATIVE Brochure Joint

 Open the catalog to page 1
MEDACTA SHOULDER SYSTEM leaflet-2

C O M P L E T E , C O N V E RT I B L E , I N N O VAT I V E Medacta Shoulder System is a modular solution that features a broad range of options, TIGROWTH COATING wide-ranging sizes, adjustable offsets and an innovative design, both in the anatomic and reverse configuration. Via al dos de la roda, 60 38057 PERGINE (TN) ITALY Tel +39 0461 518901 Fax +39 0461 518902 www.eurocoating.it Cod. Fisc./Part. IVA 01305350223 MECTAGRIP TECHNOLOGY Proximal fixation in standard and short stems is achieved through Medacta’s proprietary MectaGrip technology, in conjunction with hydroxyapatite. This results in...

 Open the catalog to page 2
MEDACTA SHOULDER SYSTEM leaflet-3

C O M P L E T E , C O N V E RT I B L E , I N N O VAT I V E The anatomic configuration of Medacta Shoulder System provides a wide implant selection to help reproducing the native geometry of the humerus and the glenoid. The robust implant offering and the double eccentricity technology greatly assist in recreating each patient’s native anatomy. ANATOMIC GLENOID ANATOMIC METAPHYSIS EXTENSIVE SIZE RANGE TRUE ANATOMIC RECONSTRUCTION 10 sizes are available to provide a wide range mismatch with the humeral head. PROVEN MATERIAL 3 angle options (128°, 135°, 142°) to help matching and reproducing the...

 Open the catalog to page 3
MEDACTA SHOULDER SYSTEM leaflet-4

C O M P L E T E , C O N V E RT I B L E , I N N O VAT I V E The reverse configuration is characterized by a semi-inlay design that reduces risks correlated with onlay platforms and overcome the limitations of previous inlay designs. Moreover, with an innovative design of the liner, the surgeon has the opportunity to adapt the system to the patient with options for reverse neck shaft angle. REVERSE HUMERAL METAPHYSIS & LINER SEMI-INLAY DESIGN The semi-inlay design helps preventing excessive humeral distalization and lateralization and reducing the risk of scapular notching. TUBEROSITY RESTORATION...

 Open the catalog to page 4
MEDACTA SHOULDER SYSTEM leaflet-5

Medacta International SA Strada Regina, 34 - 6874 Castel San Pietro - Switzerland Phone +41 91 696 60 60 - Fax +41 91 696 60 66 [email protected] Find your local dealer at: medacta.com/locations All trademarks and registered trademarks are the property of their respective owners. This document is not intended for the US market. Please verify approval of the devices described in this document with your local Medacta representative. Medacta Shoulder System Leaflet ref: 99.81MSS.11 rev. 00 Last update: June 2021