
Catalog excerpts

TECHNICAL FEATURES THE MYSPINE JOURNEY PATIENT MATCHED TECHNOLOGY The MySpine Pedicle Screw Placement guides are made to match the individual patient’s anatomy. U N I Q U E A N AT O M I E S PAT I E N T- M AT C H E D S O L U T I O N S MAXIMIZED STABILITY MySpine guides are positioned on the vertebra using distinct references, such as the spinous and transverse processes, in order to achieve the maximum stability. 1. Medacta receives the CT scan of the patient‘s spine. 2. MySpine pre-operative planning commences with the 3D reconstruction of the spine. 3. Following the surgeon’s preferences, virtual positioning of the implants is proposed. This planning can be modified if required. 4. Once the planning has been validated by the surgeon, the in-house manufacturing process starts. MYSPINE EDUCATION PROGRAM MINIMIZED INVASIVENESS The MySpine guides are designed to preserve the patient’s anatomy. The M.O.R.E. Institute has created a comprehensive Education Program which supports the surgeon in the application of the MySpine system through: ■ Reference Center You will have the opportunity to visit a Reference Center and attend live MySpine surgeries. ■ Learning Center The Learning Center offers the opportunity to attend a MySpine workshop, meet experienced surgeons and discuss the clinical and economic benefits of the MySpine technology. ■ Support MAXIMIZED VISIBILITY Distal windows enhance the field of view during all surgical steps. Upon request, you will receive the assistance of an experienced Reference Surgeon to attend your first surgery in your own hospital. ■ Continuous Education You can continue your education through MySpine user meetings, M.O.R.E. International events, Reference Center visits and other educational tools. Designed for you by you! REFERENCES Simply contact Medacta and we will create an Education Program for you! [1] Lamartina et al. Adolescent idiopathic scoliosis surgery with patient-specific screw placement-guide Eur Spine J. 2014 Dec;23(12). MySPINE VIDEO CASE / REDUCED DOSE RADIATION [2] Lamartina et al. Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J. 2015 Nov;24(7). MySPINE ACCURACY VS FREE HAND [3] Putzier et al. A New Navigational Tool for Pedicle Screw Placement in Patients with Severe scoliosis: A Pilot Study to Prove Feasibility, Accuracy, and Identify Operative Challenges. J Spinal Disord Tech. 2014 MySPINE PILOT STUDY [4] Landi et al. Spinal Neuronavigation and 3D-Printed Tubular Guide for Pedicle Screw Placement: A Really New Tool to Improve Safety and Accuracy of the Surgical Technique? J Spine 2015, 4:5 MySPINE ACCURACY VS GUIDED TECHNIQUE [5] Landi et al. 3D Printed Tubular Guides for Pedicle Screw Placement: The Answer for the Need of a Greater Accuracy in Spinal Stabilization. Orthop Muscular Syst 2015, 4:3 MySPINE ACCURACY / EASE OF USE [6] Farshad et. al. Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study. Eur Spine J. 2016 [7] Gelalis et.al. Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation technique. Euro Spine Journal, 2012 [8] Landi et al. Pedicle screw placement accuracy with patient-matched targeting guides: a cadaveric study and first clinical experiences. 8th M.O.R.E. International Symposium, LUGANO APRIL 22-23, 2016. All trademarks and registered trademarks are the property of their respective owners. Medacta International Strada Regina - 6874 Castel San Pietro - Switzerland Phone +41 91 696 60 60 - Fax + 41 91 696 60 66 Info@medacta.ch -www.medacta.com Surgical Technique Brochure MySpine Leaflet 99.my46.11 rev.02 Last update: March 2017
Open the catalog to page 1
U N I Q U E A N AT O M I E S PAT I E N T- M AT C H E D S O L U T I O N S UNIQUE ANATOMIES PATIENT-MATCHED SOLUTIONS ACCURATE SCREW POSITIONING COST SAVING MySpine is a tailor made patient specific spine vertebrae guide, created to lead the surgeon through the critical steps of accurate pedicle screw placement whilst reducing the surgical time and intra-operative X-ray radiation. The MySpine guides are made to match the surgeon’s pre-operative planning. Reducing treatment costs is crucial for all Hospitals. To this end, the MySpine system is a good tool to act on the following: STANDARD...
Open the catalog to page 2All Medacta catalogs and technical brochures
-
PowerSuture leaflet
2 Pages
-
PowerKnot leaflet
2 Pages
-
MectaQTH leaflet
2 Pages
-
FairFix leaflet
2 Pages
-
M-ARS ACL leaflet
2 Pages
-
Adult Scoliosis Patient brochure
24 Pages
-
M.U.S.T. SI Patient leaflet
8 Pages
-
MySpine MC Patient brochure
12 Pages
-
Sterile Implants leaflet
10 Pages
-
M.U.S.T. leaflet
2 Pages
-
M.U.S.T. MIS leaflet
2 Pages
-
M.U.S.T. Mini leaflet
2 Pages
-
MectaLIF leaflet
2 Pages
-
MectaLIF Anterior leaflet
2 Pages
-
MectaLIF TIPEEK leaflet
2 Pages
-
Mecta-C leaflet
2 Pages
-
Mecta-C Stand Alone leaflet
4 Pages
-
MySpine S2AI leaflet
4 Pages
-
MySpine MC leaflet
2 Pages
-
HIGHCROSS leaflet
2 Pages
-
GASTON leaflet
2 Pages
-
MYHIP leaflet
2 Pages
-
M-VIZION leaflet
5 Pages
-
MPACT System leaflet
2 Pages
-
VERSAFITCUP CC TRIO leaflet
2 Pages
-
MINIMAX leaflet
2 Pages
-
SMS leaflet
3 Pages
-
MASTERLOC leaflet
2 Pages
-
QUADRA System leaflet
2 Pages
-
QUADRA-P System leaflet
4 Pages
-
AMISTEM System leaflet
2 Pages
-
AMISTEM-P leaflet
2 Pages
-
AMIS EXPERIENCE brochure
28 Pages
-
MYSHOULDER patient leaflet
8 Pages
-
MYSHOULDER leaflet
4 Pages
-
MOTO Medial patient leaflet
8 Pages
-
GMK Sphere patient leaflet
8 Pages
-
MyKnee patient leaflet
16 Pages
-
Efficiency KneePack flyer
2 Pages
-
GMK Revision System leaflet
2 Pages
-
MOTO MEDIAL leaflet
4 Pages
-
GMK UNI Anatomic leaflet
2 Pages
-
GMK Efficiency leaflet
2 Pages
-
MyKnee leaflet
4 Pages
-
GMK Primary leaflet
2 Pages
-
GMK Sphere leaflet
3 Pages