video corpo

posterior cruciate ligament
16Pages

{{requestButtons}}

Catalog excerpts

posterior cruciate ligament - 1

JiectaPCL POSTERIOR CRUCIATE LIGAMENT

Open the catalog to page 1
posterior cruciate ligament - 2

MectaPCL Product Catalogue NOTE The MectaPCL Set allows to perform the surgical steps described in this product catalogue.

Open the catalog to page 2
posterior cruciate ligament - 4

MectaPCL Product Catalogue 1. GR AFT EXTR ACTION AND PREPAR ATION If an autologous tendon is used, harvest the graft using a tendon stripper within Medacta System. Both closed (Ref. 05.05.10.0023) and open (Ref. 05.05.10.0024) configurations are available. Position the tendon on the preparation table (Ref. 05.05.10.0009) for the cleaning and reinforcement phase. The preparation table is composed of a plastic cleaning panel (Ref. 05.05.10.0011), two graft clamps (Ref. 05.05.10.0010), a loop sizer (Ref. 05.05.10.0083), a support dedicated to Medacta Extracortical Femoral Button (Ref....

Open the catalog to page 4
posterior cruciate ligament - 5

Rotate the device counterclockwise to stabilize it on the preparation table (it will only rotate in one direction). Slide the instrument to the desired position. To properly evaluate the length of the button loop, the instrument has to lie flat against the femoral button support (image 7). To disassemble the device, rotate the instrument 90° degrees clockwise within the preparation table rail (it will only rotate in one direction) and remove it. 2. GR AFT SIZE EVALUATION The graft sizer has holes to help evaluate the reinforced graft size while the graft is assembled on the preparation...

Open the catalog to page 5
posterior cruciate ligament - 6

MectaPCL Product Catalogue 3. TIBIAL TUNNEL CREATION Tibial Aimer The tibial aimer is used to create a tunnel in the tibial bone in correspondence with the PCL tibial insertion site. The tibial aimer (Ref. 05.05.10.0087) has an adjustable angle (from 35° up to 60°) between the drill axis and the tibial plateau reference plane. With reference to image 14, the instrument’s main features: tip enables • Theaimer on theproper positioning and firm fixation of the posterior PCL insertion site A dedicated lever (bullet lever) enables bullet fixation, • preventing it from slipping from the lower arc...

Open the catalog to page 6
posterior cruciate ligament - 7

Dilator With Quick Connection Handle The dilator (from Ref. 05.05.10.0060 up to Ref. 05.05.10.0072) can be used to dilate both femoral and tibial tunnels. Each dilator is cannulated in order to slide along a Ø2.4 mm k-wire. Different sizes are available (head diameter from Ø6 mm up to Ø12 mm, by 0.5 mm increments) and must be selected according to the size of the reinforced graft. Slide Hammer The slide hammer (Ref. 05.05.10.0001) has been designed with a self-locking mechanism to be coupled with the quick connection handle. It enables easy removal of the dilator in case of significant...

Open the catalog to page 7
posterior cruciate ligament - 8

MectaPCL Product Catalogue 4. FEMOR AL TUNNEL CREATION Femoral Aimer The femoral aimer (Ref. 05.05.10.0088) is used to create a hole in the femoral bone in correspondence with the PCL femoral insertion site. • Cannulated straight shaft • Tip with circumferential radial edges corresponding to diameters Ø7 - 10 mm • Circumferential laser markings for edge diameter identification The instrument is cannulated for use with a Ø2.4 mm k-wire (Ref. 05.05.10.0026). Furthermore, it features a sequentially radially cut tip that permits the vision and comparison with the femoral insertion site of the...

Open the catalog to page 8
posterior cruciate ligament - 9

Cannulated Headed Reamers The cannulated headed reamers (from Ref. 05.05.10.0035 up to Ref. 05.05.10.0049 and Ref. 05.05.10.0054) are designed to slide along a Ø2.4 mm k-wire and are used for femoral and tibial tunnels overdrilling. The cannulated headed reamers are available in 16 sizes (from Ø4.5 mm up to Ø12 mm with 0.5 mm increments). 5. GR AFT PASSAGE PREPAR ATION PCL Rasp The PCL rasp (Ref. 05.05.20.0089) is used to rasp soft tissue or bone fragments, that may prevent passage of the graft through the joint, from the posterior tibial surface. • Tip with unilateral 8mm x 5mm rasping...

Open the catalog to page 9
posterior cruciate ligament - 10

MectaPCL Product Catalogue Cannulated screwdriver: The table below shows the compatibility between the available MectaScrews PEEK and the screwdrivers. SCREW DIAMETER (mm) SCREWDRIVER TORX Screwdriver The screwdriver is used to properly place the Medacta PEEK interference screw (MectaScrew PEEK), ensuring the appropriate fixation of the graft. Both cannulated and noncannulated versions are available. In case of cannulated screwdriver, a Ø 1.1 mm Nitinol guidewire (Ref. 05.05.10.0075) is available to guide the insertion. NOTE: each screwdriver is marked with the compatible screws diameter....

Open the catalog to page 10
posterior cruciate ligament - 11

7. INSTRUMENT TRAYS Metal trays designed with dedicated brackets to contain the instruments of the set. Sports Medicine - Knee General Tray Sports Medicine - Knee Preparation Table Tray MectaACL SB Tray - Transtibial Approach & Cannulated Screwdrivers MectaACL SB Tray - Anteromedial Approach & Cannulated Screwdrivers MectaACL SB Tray - Transtibial Approach & NonCannulated Screwdrivers, w/o dilators Cannulated Headed Reamers Tray Sports Medicine - MectaPCL Tray

Open the catalog to page 11
posterior cruciate ligament - 12

MectaPCL Product Catalogue

Open the catalog to page 12
posterior cruciate ligament - 14

MectaPCL Product Catalogue

Open the catalog to page 14
posterior cruciate ligament - 15

Part numbers subject to change. NOTE FOR STERILISATION The instrumentation is not sterile upon delivery. It must be cleaned before use and sterilised in an autoclave in accordance with the regulations of the country, EU directives where applicable and following the instructions for use of the autoclave manufacturer. For detailed instructions please refer to the document "Recommendations for cleaning decontamination and sterilisation of Medacta International orthopaedic devices” available at www.medacta.com.

Open the catalog to page 15
posterior cruciate ligament - 16

Medacta International SA Strada Regina - 6874 Castel San Pietro - Switzerland Phone +41 91 696 60 60 - Fax +41 91 696 60 66 info@medacta.ch Find your local dealer at: medacta.com/locations All trademarks and registered trademarks are the property of their respective owners. This document is not intended for the US market. Please verify approval of the devices described in this document with your local Medacta representative. MectaPCL Product Catalogue ref: 99.108SMK.180 rev. 02 Last update: October 2019

Open the catalog to page 16

All Medacta catalogs and technical brochures

  1. CANNULA SYSTEM

    12 Pages

  2. Ti-PEEK

    2 Pages

  3. MyKnee

    2 Pages

  4. Mpact System

    2 Pages

  5. MiniMAX

    2 Pages

  6. Masterloc

    2 Pages

  7. GMK Sphere

    2 Pages

  8. GMK Revision

    2 Pages

  9. sphere

    24 Pages

  10. bipolar head

    2 Pages

  11. M.U.S.T.

    2 Pages

  12. MySpine

    2 Pages

  13. Cone

    2 Pages

  14. Quadra

    2 Pages