Virus/Bacteria and odour filter with overflow protection Virus/Bacteria filter with overflow protection Virus/Bacteria filter Medela offers a vast portfolio of disposable filters that are seamlessly compatible with all Medela healthcare devices. They enable Healthcare Professionals to custom-configure their suction system to suit a variety of hygienic requirements. Intended use/purpose • Bacteria filters keep bacteria from entering the pump and environment. • Overflow protection prevents an overflow. • Odour filter protects the environment from odours. The active charcoal neutralizes odour. • Virus filters prevent viruses from entering the pump and environment. Note: The product is to be used with the Medela aspiration pump source and additionally is tested to be used with wall vacuum systems according ISO 10079-3. WARNING • This is a single use product not intended to be reprocessed. Reprocessing could cause loss of mechanical, chemical and/ or biological characteristics. Reuse could cause cross contamination. • When combining Medela parts and a third party interfacing device, the user takes responsibility for the entire system and should test the combination to ensure that the performance and safety are properly maintained. Bacteria filter with overflow protection, conical connections KEY DIFFERENTIATORS Minimising the risk from Infection with high quality protection system for both the Health Care Professional (HCP) and Patient Virus and bacteria filter system prevents from cross contamination with filtration efficiency greater than 99.9 %, providing high quality protection and hygiene standards for both HCP and patient (see chart 1 in page 3). The filter variety is compatible to Medela Dominant Flex, Basic and Vario 18 Pump portfolio and supports to optimise the protection from the risk of infection for surgical and airway procedures. For optimal hygiene standards and odour avoidance Bacteria filters provide the first, fundamental level of hygienic protection, a basic requirement if the Healthcare system does not include an embedded bacterial filter. • Overflow filters offer an essential safety mechanism to prevent fluids from entering the pump or central vacuum system. Two redundant overflow mechanisms should be present in any aspiration system. • Odour membranes effectively trap gases and odours, especially useful in containers used over multiple hours. • To ensure safety for patients and hospital staff, the pump filter exchange frequency should be performed according to the instructions for use and in-line with applicable local infection control policy. • Filtering capacity (Bacteria filter) 99.985 % for particles larger than 0.3 pm. • Filtering capacity (Virus filter) 99.99984 % for particles larger than 0.03 pm. Reliable with long medical suction expertise Known and trusted over 60 years* for medical suction expertise, Medela offers high quality solutions for a wide range of clinical applications, while the technical service support is always on availability for any inconvenience occurred. For more information please read the Instructions for Use. * Medela PVS exists in the global market since 1981 medela >>THE SCIENCE OF CARE™
Open the catalog to page 1Filters with Overflow Protection Bacteria filter with overflow protection Medela connections Item number Virus filter with overflow protection Medela connections Conical connections Item number Bacteria/odour filter with overflow protection Item number Suctioning will be interrupted when the filter is wet/moist or clogged. Perform filter test before each patient. Bacteria filter Item number Virus filter Item number Bacteria/odour filter Item number Suctioning will be interrupted when the filter is clogged. Perform filter test before each patient. Filter Exchange • In case of overflow or clogging,...
Open the catalog to page 2Chart 1 Medela filter systems protect from bacteria with 99.9% efficiency. Filtration Efficiency μm (Micrometer) 1000 Beach Sand 1’000–400 Red Blood Cell 8–2 Yeasts/Funghi 4–0.8 Particles visible to the human eye > 35 μm Reference particles Range of Medela bacteria filters 1’000–0.3 μm Range of Medela virus filters 1’000–0.03 μm ©Medela AG, 12.02.2020, Data on file with Medela AG Laboratory tested high virus retention grades of 99.99 % for particles larger than 0.03 μm Captures following types of Coronaviruses: 2019-nCoV, SARS-CoV, HCoV NL 63 and HKU
Open the catalog to page 3Reusable Collection System Item number Reusable 1 l set with PSU suction jar 077.0715 Reusable 2 l set with PSU suction jar 077.0716 Disposable Collection System Suction jar PC, 1.5 l Disposable suction liner 1.5 l Disposable suction liner 1.5 l with solidifier Tubing, silicone (selection of range) Item number Silicone tubing 0 7x12 mm, without coupling pieces, 1 m 077.0901 Silicone tubing 0 7x12 mm, without coupling pieces, 2 m 077.0902 Silicone tubing 0 7x12 mm with 1 coupling piece, 60 cm 077.0912 Silicone tubing 0 7x12 mm with 1 coupling piece, 100 cm 0770913 Silicone tubing 0 7x12 mm with...
Open the catalog to page 42 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
20 Pages
2 Pages
20 Pages