Specifications
The device uses an oscillometric technique for non-invasive blood pressure measurement with a range of 20-260 mmHg for adults and 20-130 mmHg for neonates. Pulse measurement ranges from 30-220 BPM. Systolic and diastolic accuracy have a mean error of less than ±5 mmHg and a standard deviation of less than ±8 mmHg.

Pulse Oximetry and Heart Rate
The SpO2 range is 1-100% with a resolution of 1%. Pulse rate ranges from 2-255 BPM with a resolution of 1 BPM. Reading accuracy for SpO2 is ±2% for 100-70% and ±3% for 69-60%. Pulse accuracy is ±2 BPM.

Temperature Readings
Temperature can be measured in both Fahrenheit and Celsius with an accuracy of ±0.3°F/±0.2°C. The patient temperature range is 84.2-107.6°F/29-42°C.

Electrical Ratings
The device operates on AC 100-250 V, 50/60 Hz and includes a rechargeable internal battery with a runtime of up to 3 hours.

Environmental Conditions
The device operates under atmospheric pressure of 770 to 282 mmHg and humidity of 5 to 95% (non-condensing). Operating temperature is 0 to 40°C, and storage temperature can reach up to 85°C.

Key Features
The compact system monitors SpO2, pulse rate, NIBP, and temperature. It features a bright LCD screen, separate LED displays for blood pressure readings, a built-in printer, and a nurse call facility. It supports connectivity to other equipment, 24-hour data storage, and data transfer to a computer. The device is suitable for use in various medical settings including ICUs, surgery rooms, and ambulances.

Applications
The device is ideal for monitoring patients from neonates to adults in environments such as ICUs, surgery rooms, emergency care, diagnostic centers, hospitals, physician offices, specialty clinics, and ambulances.
See more

Catalog excerpts

Model 960P Vital Sign Monitor-1

Pi//se Oximeter with Waveform, Non-Invasive Blood Pressure and Temperature Ideal for monitoring any patient category from neonates to adults Surgery Room, Emergency Care, Diagnostic Centers, Physician Offices, Specialty Clinics, f • Compact Pulse Oximetry System for monitoring Oxygen Saturation (Sp02), Pulse Rate (BPM), Non-Invasive Blood Pressure (NIBP) and Temperature. '• Bright, high resolution LCD screen to display the Pleth Waveform as well as the Sp02 and Pulse Rate readings • Separate bright Led displays for systolic, diastolic and mean Blood Pressure readings • Built-in printer facility for printing reports immediately • Accurate BP readings in less than 40 seconds • Nurse call facility that alerts the nurse station in case • Connectivity to other life saving equipment • 24 hour Patient Data storage and trend data • Patient data transfer to a computer • 5 different languages option for easy access to clinicians Software for patient data analysis Monitors Adult, Pediatric and Neonate Patients www.mediaidinc.com [email protected] Non-Invasive Blood Pressure Measurement Range: Systolic Accuracy: Diastolic Accuracy: Pulse Oximetry and Heart Rate Reading Accuracy: Temperature Readings Patient Temp Range: Measurement Time: Electrical Ratings Battery type: Mean Error less than ± 5 mmHg. SD less than ± 8 mmHg. Mean Error less than ± 5 mmHg. SD less than ± 8 mmHg. placement and patient condition. Rechargeable internal battery with Sp02 and NIBP readings once every 10 minutes. Environmental conditions (Acceptable conditions for operating, storage and transport) Atmospheric Pressure: Operating Temp: