Overview: The document provides technical specifications and features of the MCA® ISO 210 Series Isolation Units, designed for healthcare environments such as patient rooms, operating theaters, and intensive care units. These units are a result of Belgian-Swiss cooperation and are CE approved, adhering to ISO 9001 and ISO 14001 standards.
Specifications:
  • Unit Casing: White epoxy RAL 9010 with anti-bacterial properties.
  • Size and Weight: Two-part unit measuring 32 x 43 x 14 cm and 32 x 42 x 12 cm, weighing a total of 7.1 kg including the filter cartridge.
  • Electricity: Operates on 220 – 240 V / 50 – 60 Hz, consuming 35 to 80 Watts.
  • Installation: Wall-mounted with easy assembly, requiring only half a day.
  • Operation: Controlled remotely by key, with four speed levels including a silent night mode.
  • Clean Air Capacity: Ranges from 70 m3 to 135 m3 per hour, suitable for areas up to 15 m2 or 40 m3.
  • Maintenance: Minimal, with an annual filter change required.
  • Guarantee: 36 months excluding the filter cartridge, with a maintenance contract.
Filter Details:
  • Filter Cartridge: ULPA 15 quality, providing 99.9995% efficiency on particles from 0.1 to 0.3 µm, tested to EN1822 standards.
  • Optional Filters: Includes a combined system with pre-filter F7, activated carbon, and HEPA 14.
  • Security Features: One-way airflow prevents reverse contamination, with integrated alarms for pressure differences.
Additional Features:
  • Remote Control: RC200 with pressure difference display and integrated security alarms.
  • Optional Pre-filtration: F5 pre-filtration available for additional security.
  • Fire Protection: Compatible with fire-resistant grills or dampers.
General Information: The units are infection control friendly, easy to clean, and ensure a secure airtight connection between the filter and ventilation units. They are designed for rapid installation and provide permanent airflow security.
See more

Catalog excerpts

ISO 210-1

A BFlqiAN " Swiss CoOpERATiON Production A Belgian - Swiss Cooperation Yes CE approved - ISO 9001 - ISO 14001 - Safety Class 1Yes Unit Casing White epoxy RAL 9010, anti-bacterial standard Yes Weight 4.7 (filter unit) + 2.4 (fan unit) = 7.1 kg filter cartridge included Yes Installation Wall mounted - easy assembly - A day work only Yes 100 % security on airtight-connection between filter- & ventilator unit Yes Operation Remote control by key (only hospital staff operates system) Yes 4 speed levels - silent «night level» for patients Yes Controls Remote Control with 4 operational levels and LED display on unit Yes Clean air From 70 m3 up to 135 m3 / hour Yes capacity Area capacity Built for area’s up to approx. 15 m2 / 40 m3 - patient rooms, OT, ICU’s Yes Security One way air-flow (no reverse air-flow possible when not operational!) Yes Maintenance None, except for filter change - 1x/year Yes Guarantee 36 months (excl. Filter cartridge) with maintenance contract Yes Filter Cartridge ULPA 15 Quality (3,7 m2): 99,9995 % on 0.1 to 0.3 pm!!, tested EN1822 Yes MedicCleanAir filters have been tested up to 0.017 pm! Filter control LED display (green-yellow-red) on filter unit Yes Extra Remote control RC200 with permanent pressure (Pa) difference display (difference Opt between the patient room and adjacent area = total security that the room is in pressure difference) Integrated security alarm in case pressure difference drops permanently after 60 seconds Integrated automatic features to maintain the pre-installed required pressure difference Additional F5 pre-filtration on the outside of the Unit to be changed every time patient Opt changes (when patient changes - room is disinfected - pre-filter can be changed as well) Optional Filter Instead of ULPA 15, one can choose for a Opt cartridge Combined 3 filter system pre-filter F7 + activated carbon + HEPA 14 System 1 Fine dust pre-filter, Class F7 - SN EN 779 (0,5 m2) System 2 Activated Carbon non impregnated - natural product System 3 HEPA, Class H14 - SN EN 1822 - (2,5 m2) Individually leak tested Casing Instead of white epoxy anti-bacterial coating, stainless steel casing Opt Fire Protection Compatible with fire resistant grills or circular fire damper cartridges 30’or 60’ to prevent Opt fire from spreading to other area’s (only with wall assembly) General Infection control friendly - epoxy white anti bacterial or stainless steel casing Yes ensures easy cleaning and user friendly due to changeable pre-filter. Rapid to install, A day work only Yes The consumable is the filter cartridge to be changed every year (after 12 months) Yes 100 % security on airtight connection between filter- & ventilation unit Yes Permanent air flow security through one-way-airflow guarantee! Yes (no risk of blowing contamination back into the room due to reverse airflow) Pre-filter guarantees longer lifetime of the ULPA or HEPA filter Yes Permanent security over pressure difference including automatic features Opt MedicCleanAir®, V09-2018 / Yes = standard, Opt = optional / Technical changes permitted without notice

 Open the catalog to page 1
ISO 210-2

Standard ISO 210 Device for wall assembly – Filter- & ventilator unit – rear vieuw with tube front vieuw with filter unit (ULPA 15 level) connections & cables connections Standard Remote Control operated by key with positions 0 – 1 – 2 – 3 – 4 and LED display (0-1-2-3-automatic + filter check) Remote Control by key with permanent Additional pre-filtration on the outside of pressure difference display, cable with filter unit Filter cartridge ULPA 15 connection plugs, short instruction manual for hospital staff (head nurses, technical department, etc.) Detail of the filter unit with clear vieuw...

 Open the catalog to page 2

All Medic Clean Air catalogs and technical brochures

  1. ISO 520

    2  Pages

  2. ISO 120

    2  Pages

  3. PRO 110

    2  Pages

  4. COMBI 1.1

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.