ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 1

ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY Menfis Division Divisional Office: Via della Beverara, 46/D - 40131 Bologna Italy. Tel +39 051 635 10 74 - Fax +39 051 635 10 81 E-mail: info@menfis.it - Web site: www.menfis.it

Open the catalog to page 1
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 3

Catheters for oesophageal manometry, paediatric Catheters for oesophageal manometry, adult Catheters for anorectal Manometry, paediatric Catheters for anorectal Manometry, adult Biofeedback Swallow sensor and respiratory sensor Pressure Transducers Buffer solution, pH probes * Technical data can be changed without any notice

Open the catalog to page 3
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 4

Lines and Accessories for Gastroenterology: CATHETERS FOR OESOPHAGEAL MANOMETRY - SINGLE USE 5-way catheter for oesophageal manometry paediatric type. Fitted with a central lumen of 1.1 mm in diameter that opens at the tip and 4 lumina, which open with 4 side-ports, 3 cm apart of 0.8 mm in diameter. The side-ports have a helicoidal arrangement. The side-port no 4 is 2 cm far from the tip. Centimetric marking from the side-port no 4. External diameter 9 Fr (3 mm). Operative length 100 cm. Total length 180 cm Made in PVC External diameter Cannula length

Open the catalog to page 4
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 5

Lines and Accessories for Gastroenterology: CATHETERS FOR ANORECTAL MANOMETRY - SINGLE USE PAEDIATRIC Ref: 5R-9-100CB 5-way catheter for anorectal manometry, paediatric version. One central lumen in diameter of 1.1 mm , which opens inside a balloon mounted on the tip of 20 ml volume. 4 lumens of 0.8 mm diameter, which open with 4 holes disposed helicoidally along the catheter 5 mm apart. The distal hole is 2,5 cm far from the balloon insertion. Centimetric marking from the distal hole. Diameter 9 Fr (3 mm). Operative length 50 cm. Total length 180 cm. Cannula made of PVC, balloon made of...

Open the catalog to page 5
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 6

Lines and Accessories for Gastroenterology: Ref: 5R-12-100VB 5-way catheter for anorectal manometry One central lumen of 1.4 mm diameter which opens into a balloon mounted on the tip. 4 lumens which open with 4 holes of .8 mm diameter radially disposed 2,5 cm far from the balloon insertion. Centimetric marking from the radial holes. Longitudinal line in correspondence of the hole no 1 , 20 cm long. Diameter 12 Fr (4 mm). Operative length 50 cm. Total length 180 cm Made of PVC. Balloon in POLYISOPRENE 1,2,3,4 External diameter Cannula length 50 cm 4 mm ( 12 Fr ) Balloon Balloon Q.ty/Box...

Open the catalog to page 6
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 7

Lines and Accessories for Gastroenterology: Ref: 9R-12-100V 9-way catheter for anorectal manometry One central lumen of 1.4 mm diameter, which opens at the tip. 8 lumens of 0.8 mm diameter which open with 8 holes radially disposed, 2,5 cm far from the tip. Centimetric marking from the radial holes. Longitudinal line in correspondence of the hole no 1, 20 cm long. Designed to study the anal sphincter. Diameter 12 Fr (4 mm). Operative length 50 cm. Total length 180 cm. Made of PVC. 1,2,3,4,5,6,7,8 Ref: 9R-12-100VB 9-way catheter for anorectal manometry One central lumen of 1.4 mm diameter,...

Open the catalog to page 7
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 8

Lines and Accessories for Gastroenterology: Ref: 9R-12-100CB 9-way catheter for anorectal manometry. One central lumen of 1.4 mm diameter, which opens inside a balloon mounted on the tip. 8 lumens of 0.8 mm diameter, which open with 8 holes, disposed helicoidally along the catheter 5 mm apart. The distal hole is 2,5 cm far from the balloon insertion. Centimetric marking from the distal hole. Diameter 12 Fr (4 mm). Operative length 50 cm. Total length 180 cm. Cannula made of PVC, balloon made of POLYISOPRENE . External diameter Cannula length 50 cm 4 mm ( 12 Fr ) Balloon Balloon Q.yà/Box...

Open the catalog to page 8
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 9

Lines and Accessories for Gastroenterology: CATHETERS FOR GDI MANOMETRY - SINGLE USE Ref: 9G-12-130C 9-way catheter for GDI manometry. One central lumen of 1.4 mm diameter, which opens inside a balloon mounted on the tip. 8 lumens of 0.8 mm diameter, which open with 8 holes, disposed helicoidally at 3, 5, 5, 3, 3, 3, 3, 3 from the tip. The distal hole is 3 cm far from the balloon insertion. Centimetric marking from the distal hole. Diameter 12 Fr (4 mm). Operative length 130 cm. Total length 220 cm. Cannula made of PVC.

Open the catalog to page 9
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 10

Lines and Accessories for Gastroenterology: BIOFEEDBACK PROBES: The manometric vaginal probes In Care, code 9587 are manufactured according to the strictest safety rules and are used in the rehabilitation of the pelvic floor with the aim to obtain the restoration of the neuromuscular control in patient with urinary incontinence They are Latex-free and are supplied in single pouch. They The manometric anal probes In Care, code 9588 are manufactured according to the strictest safety rules and are used in the rehabilitation of the pelvic floor with the aim to obtain the restoration of the...

Open the catalog to page 10
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 11

Lines and Accessories for Gastroenterology: ACCESSORIES: SWL/D Swallow Sensor

Open the catalog to page 11
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 12

Lines and Accessories for Gastroenterology: TRANSDUCERS: DPT-6100 Disposable pressure transducer by PVB MX860 Reusable pressure transducer MX 1572 Disposable dome with diaphragm to be used with reusable transducer MX 860. Box of 20 items TXPd Disposable pressure transducer by BECTON DICKINSON

Open the catalog to page 12
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 13

Lines and Accessories for Gastroenterology: ELECTROMYOGRAPHY: F3001NECG Box of disposable surface electrodes (200 items per box) MA-A004/25 Disposable needle electrode, monopolar, 25 x 0,36 mm. MA-A004/38 Disposable needle electrode, monopolar,38 x 0,46 mm. MA-A004/50 Disposable needle electrode, monopolar, 50 x 0,46 mm.

Open the catalog to page 13
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 14

Lines and Accessories for Gastroenterology: Buffer Solutions: Buffer solution pH7. Bottle of 250 ml Buffer solution pH4. Bottle of 250 ml Buffer solution pH1. Bottle of 250 ml ANTIMONY PROBES SINGLE USE: Single Use, Internal reference, 2.1 mm in diameter, 1 pH sensor. Single Use, Internal reference, 2.1 mm in diameter, 1 pH sensor, LES port at 5 cm from distal

Open the catalog to page 14
ACCESSORIES AND CONSUMABLES FOR GASTROENTEROLOGY - 15

Lines and Accessories for Gastroenterology: NS 619205 Single Use, Internal reference, 2.1 mm in diameter, 2 pH sensors 5 cm apart. Pkg of 10 NS 619210 Single Use Internal reference 2.1 mm in diameter, 2 pH sensors 10 cm apart. Pkg of 10 NS 619215 Single Use, Internal reference, 2.1 mm in diameter, 2 pH sensors 15 cm apart. Pkg of 10 ANTIMONY PROBES MULTI-USE (REUSABLE APPROX 6 TIMES): 719100 Multi-use, External reference, 2.1 mm in diameter. 1 pH sensor +distal Stiffer 719205 Multi-use, External reference, 2.1 mm in diameter, 2 pH sensors 5 cm apart, + Stiffer between sensors

Open the catalog to page 15

All MEDICA catalogs and technical brochures

  1. PICO SMART

    4 Pages

  2. FLEXIPER

    2 Pages

  3. Dialyzers

    2 Pages

  4. PROTSMART TM

    6 Pages

  5. EQUAsmart®

    10 Pages

  6. HDF on line

    2 Pages

  7. Ultrafilters

    2 Pages

  8. BROCHURE 2016

    38 Pages

  9. HEMOFILTERS

    2 Pages

  10. PLASMART

    2 Pages

  11. D150/U

    2 Pages

  12. DiaPure®

    2 Pages

  13. LA25

    2 Pages

  14. CLIPPER

    2 Pages

  15. DYNO SMART

    4 Pages

  16. BLU RUNNER

    2 Pages

  17. PICO SMART

    4 Pages

  18. PICO COMPACT

    4 Pages

  19. FLOW ZIG

    2 Pages

  20. PICO FLOW2

    2 Pages