Product catalog summary
Overview: This document outlines the specifications, procedures, and recommendations for orthopedic surgical plates and screws, focusing on nail-plates and blade-plates used in bone fracture treatments and osteotomies. It also covers condylar blade-plates for lower extremity femur fractures and osteotomies.
Specifications:
  • Dynamic Hip Screw-Plates: Available in lengths from 70mm to 100mm with 1 to 8 holes, including compression screws and screwdrivers.
  • Stainless Steel DKP Screw-Plates: Offered in angles of 120°, 130°, and 140°, and lengths from 70mm to 100mm.
  • Monobloc Nail-Plates: Lengths range from 70mm to 90mm with 4 to 8 holes.
  • Goose-Neck Tibial Osteotomy Blade-Plates: Designed for angles of 90° and 100°, with lengths of 60mm and 70mm.
  • Strélitzia Condylar Blade-Plates: Available in lengths of 60mm to 80mm with 4 to 8 holes.
  • Condylar Blade-Plates: Available in 95° and 130° angles, with lengths from 60mm to 204mm and 4 to 12 holes.
  • Diaphyseal Screws: Diameters of 4.5mm or 5mm.
Procedures:
  • Dynamic Screw-Plates: Involves aiming, drilling, tapping, screwing, and compression, with X-ray verification and complementary pins for unstable fractures.
  • Monobloc Nail-Plates: Includes aiming, drilling, calibration, nailing, and diaphyseal setting, emphasizing precise alignment.
  • Goose-Neck Blade-Plates: Focuses on pin positioning, calibration, and final operation steps, crucial for upper tibia osteotomies.
  • Strélitzia Blade-Plates: Details aiming and drilling for fracture reduction.
  • Condylar Blade-Plates: Aiming and drilling involve preparing the housing at 30 or 40mm, followed by nailing and diaphyseal setting with screws.
Recommendations:
  • Ensure proper alignment and penetration of pins and screws using guides and X-ray verification.
  • Select appropriate angles and lengths of plates and screws based on specific fracture or osteotomy requirements.
  • Follow procedural steps to avoid complications like pin incarceration or nail slippage.
Important Information:
  • Major indications include true cervical fractures and certain osteotomies.
  • Bibliography references studies on fibular nonunion and blade-plate fixation for distal femoral fractures.
  • Emphasizes precise calculations and careful attention to plate direction during procedures for successful outcomes.
Instruments:
  • Includes cannulated drills, angle sights, drill bit guides, and impactors, with specific tools for Strélitzia and Swan neck nail starters.
See more

Catalog excerpts

Nail-plates and blade-plates-1

Sommaire chapitre Distributeur/Distributor 34, Av du Dr Durand- 94110 ARCUEIL - FRANCE - tél. : [33] (0) 1 46 11 16 20 E-mail : [email protected] - Site Web : http://www.medicalex.info p 1/12 Z:\Catalogue Juillet 2021\Chap6_Plaques-lames

 Open the catalog to page 1
Nail-plates and blade-plates-2

V is plaques dynamiques pour le col du fémur 130° 130° Dynamic hip screw-plates Vis plaques dynamiques Dynamic screw-plates Nombre de trous / Number of holes 1 Vis dynamique et vis à compression Dynamic screw and compression screw Désignation / Description Matériel ancillaire Ancillary material Désignation / Description Désignation / Description Extracteur de vis dynamique Extractor for dynamic screw Tarière coaxiale Coaxial drill Vis de compression Compression screw Désignation / Description Tournevis 6-pans 4,5 pour vis de compression Screwdriver for compression screw 6-sides 4,5 Désignation...

 Open the catalog to page 2
Nail-plates and blade-plates-3

Technique de pose • Setting technique Indications majeures Important information • Fractures cervicales vraies • Certaines ostéotomies • True cervical fractures. • Certain osteotomies. • Drill through the external cortical at the chosen point. •Push the pin (Ø 2,5 lg 20 cm) with the 130° protactor. • After about 60 minutes, replace the protractor with the pin-guide and finish driving the pin. The difference between the pin (200 mm) and the guide (100 mm) allows assessment of the pin’s penetration. • An X- ray test may be useful to check the pin’s status. • A complementary pin, parallel to the...

 Open the catalog to page 3
Nail-plates and blade-plates-4

Vis plaque DKP inox • Stainless steel DKP screw-plate Joint en PE / PE washer Référence Reference Rondelle / Washer Ressort / Spring Référence Reference 45.100.30 Rondelle / Washer Vis / Screw Référence Reference 45.200.70 Epaisseur Thickness Référence Reference Longueur Length Plaque dynamique / Dynamic plate Référence Reference Désignation Name Matériel ancillaire Ancillary material Désignation Description Référence Reference Désignation Description Référence Reference Porte plaque et écrou Impactor Extracteur Extractor Sommaire chapitre Distributeur/Distributor 34, Av du Dr Durand- 94110 ARCUEIL...

 Open the catalog to page 4
Nail-plates and blade-plates-5

Clou-plaque monobloc 130° • 130° monobloc nail-plate Clou-plaque Maconor Maconor nail-plate Long. en mm Length Sommaire chapitre Distributeur/Distributor 34, Av du Dr Durand- 94110 ARCUEIL - FRANCE - tél. : [33] (0) 1 46 11 16 20 E-mail : [email protected] - Site Web : http://www.medicalex.info p 5/12 Z:\Catalogue Juillet 2021\Chap6_Plaques-lames

 Open the catalog to page 5
Nail-plates and blade-plates-6

Technique de pose • Setting technique • Percer la corticale externe au point choisi. • Enfoncer la broche (de 20 ou 25/10) à l’aide du rapporteur, à 130°. • Après 60 mn environ, remplacer le rapporteur par le guide-broche et terminer l’enfoncis. La différen ce entre la broche (200 mm) et le guide (100 mm) permet d’apprécier facilement la pénétration de la broche. • Radio de contrôle pour vérifier la situation de la broche. • Drill through the external cortical at the chosen point. • Drive the pin (of 20 or 25/10) with a protractor, generally at 130°. • After about 60 minutes, replace the protractor...

 Open the catalog to page 6
Nail-plates and blade-plates-7

L ame-plaque col de cygne pour ostéotomie tibiale Goose-neck tibial osteotomy blade-plate Plaque 3 trous Three-holed plate Plaque Grodet Grodet plate Angle Angle Angle Angle Plaque Kerboull Kerboull Plate Angle Angle Broche bicolore, 1 pointe, Ø 2 mm, longueur 20 cm Bi-colored pin, one point, 2 mm Ø, 20 cm long Bibliographie / Bibliography : • M. Ramanoudjame, E. Vandenbussche, T. Baring, N. Solignac, B. Augereau, and T. Gregory, “Fibular nonunion after closed-wedge high tibial osteotomy,” Orthop. Traumatol. Surg. Res., 2012. Lame-plaque Gardes • Gardes condylar blade-plate 90° Désignation /...

 Open the catalog to page 7
Nail-plates and blade-plates-8

Lame-plaque Strélitzia • Strélitzia condylar blade-plate Droit / Length Gauche / Left Bibliographie / Bibliography : • E. Vandenbussche, M. LeBaron, M. Ehlinger, X. Flecher, G. Pietu, and SOFCOT, “Blade-plate fixation for distal femoral fractures: a case-control study.,” Orthop. Traumatol. Surg. Res., 2014 Sommaire chapitre Distributeur/Distributor 34, Av du Dr Durand- 94110 ARCUEIL - FRANCE - tél. : [33] (0) 1 46 11 16 20 E-mail : [email protected] - Site Web : http://www.medicalex.info p 8/12 Z:\Catalogue Juillet 2021\Chap6_Plaques-la

 Open the catalog to page 8
Nail-plates and blade-plates-9

T echnique de pose col de cygne Setting technique gooseneck Indications majeures Important information Ostéotomies de l’extremité supérieure du tibia. Important information : Osteotomies of the upper extremity of the tibia 1) Mise en place de la broche Il faut partir de l’angle de l’implant à utiliser, soit en règle générale, pour les valgisations 90°. Exemple: pour valgiser de 8° on aura : 90° - 8° = 82°. Il faudra fixer le rapporteur à 82°. Start from the implant angle to be used, which is normally 90° for valgisations. Example: for a 8° valgisation, you would have : 90° - 8° = 82°. The protractor...

 Open the catalog to page 9
Nail-plates and blade-plates-10

T echnique de pose lame plaque Strelitzia Setting technique blade-plate Strelitzia Important information Indications majeures Fractures and osteotomies of the lower extremity of the femur Fractures et ostéotomies de l’extremité inférieure du fémur • Fracture réduite et broche en place à 95°: Amorcer le logement sur 30 ou 40 mm avec l’outil défonceur. • Bien calculer le futur plan de la plaque pour ne pas “manquer” la diaphyse. • Reduced fracture and pin in position at 95°: start preparing the housing at 30 or 40 mm with the nail-starter. • Calculate well the future plane of the plate so as not...

 Open the catalog to page 10

All Medicalex catalogs and technical brochures