video corpo

Thorax

Thorax
1 / 24 PagesView full catalog

Thorax

Product catalog summary
Instructions for Use: Instructions are available in PDF format via a QR code on the product label. Paper copies can be requested within seven days at no cost.
Product Specifications: The document details thoracic medical devices such as Borrelly's staples, splints, and connectors, available in stainless steel and titanium, with specific references for each material and size.
Ancillary Materials: Includes crimping pliers for various applications, with specific references for each tool.
Custom Implant Design Process: Involves 3D simulation, modeling in SolidWorks, designing the staple splint, and manufacturing, aiding in preoperative planning and optimizing surgical procedures.
Advantages of Custom Implants: Benefits include optimized operations, reduced costs, and patient-tailored implants.
Pectus Excavatum Treatment: Describes the use of titanium plates for surgical correction, detailing procedure and post-operative care, designed for patients from adolescence onwards.
Nuss Bar for Children: Used for patients aged 5 to 22, attached with stainless steel wire, less traumatic, typically removed 2-3 years post-installation.
Bibliography: References studies and articles related to thoracic surgery and implants.
Specifications: Details specifications for medical devices, including manual bending tools and vacuum bells for non-invasive treatment of funnel chest, with lengths specified in millimeters.
Procedures: Outlines the procedure for using the Eckart Klobe Vacuum Bell, emphasizing medical examination and supervised first use, application process, and optimal usage times.
Recommendations: Persistent use of the Vacuum Bell is recommended for effective correction of funnel chest, with advice on selecting the appropriate type based on criteria like age and physical characteristics.
Technical Remarks: The Vacuum Bell is made of orthopedic silicone, with guidance on maintaining device integrity and warnings against chemical exposure.
General Remarks: Highlights the importance of physiotherapeutic exercises to complement Vacuum Bell use and improve posture, noting potential for partial regression of funnel chest.
Material Specifications: The Vacuum Bell is composed of polycarbonate, polyamide, and PVC, with safety recommendations for using manufacturer-provided suction bulbs.
Cleaning and Maintenance: The Vacuum Bell should be cleaned with specific solutions, avoiding disinfectants that may cloud the viewing glass, with proper operation checks before use.
Functionality: The Vacuum Bell creates a vacuum lifting the sternum and ribcage, involving reversible elastic deformation and gradual permanent transformation.
Contraindications: Not for use by individuals with skeletal, vascular, or coagulation dysfunctions.
Medical Warnings and Precautions: Users should avoid ribcage stress during treatment, manage vertigo by lying down, and avoid use after diving or high-altitude transport.
Potential Side Effects: Include skin abrasions, arm tingling, nipple irritation, gynecomastia, and bronchitis, with preventive measures suggested.
Typical Results and Duration: Initial lifting of funnel chest can occur within 2 to 4 weeks, with more pronounced effects in younger patients.
Specifications and Initial Setup: Describes the use of a Dynamic Compression System for correcting thoracic deformities, with initial correction pressure measured using a pressure sensor.
General Instructions for Use: During the first consultation, measurements are taken for creating a custom-made brace, with specific assembly and adjustment instructions.
Adverse Effects and Complications: Potential side effects include discomfort and skin issues, with pain relief and skin lesion management suggestions.
Adjustment and Monitoring: Pressure exerted should be checked and adjusted, with regular monthly checks recommended.
Treatment Duration and Recommendations: Treatment duration varies, with continued treatment advised to prevent recurrence, emphasizing proper hygiene and avoiding sleeping on the stomach.
Specifications: Describes a pressure sensor system used within the FMF® Dynamic Compression System, with key components and assembly procedure.
Assembly Procedure: Details the attachment of the compression plate to the sensor case and installation on the FMF® thoracic compression brace.
Main Indications: The pressure sensor is for use with the FMF® Dynamic Compression System to measure specific pressures.
Contraindications: Not for use on patients with significant skin lesions at the site of thoracic deformity.
Adverse Effects and Complications: Inaccurate measurements can lead to discomfort and incorrect deformity correction.
General Instructions for Use: Measurements required are the Pressure for Initial Correction (PIC) and the Pressure of Treatment (POT), taken with the provided sensor.
Measuring the Pressure for Initial Correction (PIC): Steps include attaching the compression plate, positioning the patient, and recording PIC values.
Measuring the Pressure of Treatment (POT): Steps include assembling the brace, ensuring proper setup, and measuring maximum pressure during deep inhalation.
Thorax Ruler Description and Assembly: Consists of a graduated handle and two arms, with measurements taken between the arms.
General Instructions for Use: Measurements are taken at the point of greatest protrusion, with specific required measurements listed.
Figures and Measurements: Includes figures illustrating required measurements and examples.
See more

Catalog excerpts

Thorax-1

Les instructions d’emploi ne sont plus fournies sur support papier mais au format PDF. Pour y accéder, merci de scanner le QR code situé sur l’étiquette du produit. Les instructions d’emploi sur un support papier peuvent être fournies, sans frais supplémentaires, dans les sept jours civils suivant votre demande. The instructions for use are no longer provided in paper form but in PDF format. To access them, please scan the QR code located on the product label. The instructions for use in paper form can be provided, at no additional cost, within seven calendar days of receiving your request. Sommaire chapitre 34, Av du Dr Durand - 94110 ARCUEIL- FRANCE - tél. : [33] (0) 1 46 11 16 20 E-mail : [email protected] - Site Web : http://www.medicalex.info p 1/24 Since 1967

 Open the catalog to page 1
Thorax-2

Agrafes de Borrelly • Borrelly’s staples Exemple de montage Implantation sur les côtes Assembly exemple Implantation on the ribs Agrafes Staples Référence Titane / Titanium Attelles Splints Référence Inox / Stainless steel Long. Length Référence Inox / Stainless steel Référence Titane / Titanium Raccords Connectors Raccords rectilignes • Straight connectors Référence Inox / Stainless steel Référence Titane / Titanium Raccords angulaires • Angular connectors Référence Inox / Stainless steel Référence Titane / Titanium Droite Right Gauche Left Angle Angle Référence Inox / Stainless steel Référence...

 Open the catalog to page 2
Thorax-3

Attelles agrafes monobloc en titane Titanium Splints staples Modèle 6 pattes / 6 claw model Modèle 9 pattes / 9 claw model Modèle 12 pattes / 12 claw model Long Length Long Length Implant / Implant Essais / Template Long Length Implant / Implant Essais / Template Essais / Template Implant / Implant Petit modèle / small model Grand modèle / large model Sommaire chapitre Distributeur/Distributor 34, Av du Dr Durand - 94110 ARCUEIL- FRANCE - tél. : [33] (0) 1 46 11 16 20 E-mail : [email protected] - Site Web : http://www.medicalex.info p 3/24 Since 1967

 Open the catalog to page 3
Thorax-4

Matériel ancillaire Ancillary material Référence Reference Désignation Description Pince à sertir les agrafes sur les côtes Crimping pliers for stapling on the ribs Désignation Description Référence Reference Désignation Description Pince à sertir les glissières et des raccords Crimping pliers for the sliding staples and connectors Grand modèle / Model large Pince à déssertir les glissières et des raccords Pliers for removing sliding staples and connectors Référence Reference Désignation Description Référence Reference Désignation Description Référence Reference Désignation Description Référence...

 Open the catalog to page 4
Thorax-5

Reconstruction de la paroi thoracique avec un implant sur mesure • Reconstruction of the chest wall with a custom made implant 1ere étape : simulation de la paroi thoracique complète 1st step: simulation of the complete chest wall Les coupes scanner sont importées sous Radiand. Un traitement d’image nous permet une reconstruction 3D du thorax du patient. Cette reconstruction 3D nous permet de visualiser l’ensemble de la cage thoracique pour mieux cerner la tumeur. Scanner sections are imported into Radiand. Image processing allows us to reconstruct the patient's chest in 3D. This 3D reconstruction...

 Open the catalog to page 5
Thorax-6

Plaque du Pr. Wurtz pour thorax en entonnoir Pr. Wurtz pectus excavatum Plate Long. Length Essais Template Rugines préconisées pour la dissection sous périchondrale des cartilages Recommended raspatories for subperichondrial dissection of costal cartilages Désignation / Description Référence Reference Rugine d’Obwegeser Obwegeser raspatory Désignation / Description Référence Reference Rugine Overholt Overholt raspatory Désignation / Description Référence Reference Rugine Delanoy Delanoy raspatory Après cure chirurgicale du pectus excavatum par résection sous périchondrale des cartilages hypertrophiés...

 Open the catalog to page 6
Thorax-7

Barre de Nuss pour Pectus Excavatum de l’enfant en Inox Nuss Stainless steel Pectus Excavatum bar for children Ces barres sont utilisées chez le jeune de 5 à 22 ans. Référence Elle doit être fixée avec des fils de cerclage en inox ø1,2 radio-opaque (Ref : 33.360.12) . La partie évasée de la barre permet de l’utiliser sans stabilisateur. Celle36.415.23S ci est donc moins traumatisante qu’une barre avec stabilisateur. Le design de la plaque est low profile. La 36.415.25S barre est retirée en moyenne, 2 à 3 ans après sa pose. Long. en mm /inch Lenght in mm / inch 230mm / 9" 255mm / 10" Fil de cerclage...

 Open the catalog to page 7
Thorax-8

Cloche d’aspiration Eckart Klobe pour le traitement non invasif du thorax en entonnoir The Eckart Klobe Vacuum Bell for Non-Invasive Lifting of Funnel Chest Référence 03.000.00 Désignation / Description Grande Cloche d’Aspiration (26 cm environ) pour les hommes d’une taille supérieure à 1,70 m / Large Vacuum Bell (approx. 26 cm) for male persons taller than approx. 1,70 m Petite Cloche d’Aspiration (de 19 cm environ) pour les personnes d’une taille supérieure à 1,40 m / Small Vacuum Bell (approx. 19 cm) for persons taller than approx. 1,40 m Petite Cloche d’Aspiration Type Bodybuilder (de 19...

 Open the catalog to page 8
Thorax-9

Elle doit être utilisée avec persévérance pendant une période assez longue pour parvenir à corriger le thorax en entonnoir. Lorsqu’une unité de traitement par cloche d’aspiration se termine, il faut d’abord s’attendre à une retombée partielle de l’entonnoir qui peut durer quelques minutes ou quelques heures. La forme atteinte par l’entonnoir quelques jours après l’arrêt de l’utilisation de la cloche d’aspiration peut déjà être considérée comme une amélioration. For a successful correction of the funnel chest it is necessary to apply the Vacuum Bell persistently over a long period of time. After...

 Open the catalog to page 9

All Medicalex catalogs and technical brochures

  1. Various

    14  Pages

  2. Pediatrics

    31  Pages

  3. Spine

    15  Pages

  4. Prostheses

    9  Pages

  5. plates

    23  Pages

  6. Screws

    10  Pages

  7. Staples

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.