MG E Health® WOMEN’S HEALTH & GYNECOLOGY Low-position access. Flexible electric positioning. Motorized disposable-sheet changing. Designed for gynecological examination, diagnosis and related clinical procedures.
Open the catalog to page 1CLINICAL POSITIONING & WORKFLOW Images show the MGE-D07A product and available positioning. Clinical use is determined by the care team. MGEHealth' MEDIGE INTERNATIONAL INDUSTRIES CO., LTD.
Open the catalog to page 2POSITIONING & CONTROL Electric adjustments for gynecological workflows Hand-controller operation combines positioning adjustments with electric disposable-sheet changing. 570 mm MINIMUM TABLE HEIGHT TABLE TILT RANGE ELECTRIC POSITIONING & CONTROL ■ Height adjustment for clinical access ■ Backrest elevation and lowering ■ Whole-table inclination adjustment ■ Electric disposable-sheet changing ADJUSTABLE SUPPORT COMPONENTS 180° leg-support rotation, flip-up handrails and an integrated waste basin. MGEHealth' MEDIGE INTERNATIONAL INDUSTRIES CO., LTD. www.medicalmge.com
Open the catalog to page 3PATIENT SUPPORT & MATERIALS Practical materials and adjustable accessories are designed for routine gynecological clinical workflows. Powder-Coated Finish Anti-fouling surface with corrosion-resistant finish. Integrated Waste Basin Concealed basin for routine fluid collection. PRACTICAL CLINICAL DETAILS • 180° adjustable gynecological leg supports • Flip-up handrails for flexible access • Electric disposable-sheet changing system • Dedicated emergency-stop switch
Open the catalog to page 4TECHNICAL SPECIFICATIONS Technical specifications — motion and clinical setup Specification values are reproduced from MGE-D07A Technical Specification VI .0. Overall Length 1680 mm (excluding auxiliary board) Table Height Range 570-850 mm (including mattress) Table Tilt Range -20° to +20° Leg-Support Adjustment Adjustable angle and direction Sheet-Changing System Waste Basin Emergency Stop Braking System Control System Primary Application Flip-up design Electric disposable-sheet changing Integrated / concealed Dedicated emergency-stop switch Three-section central brake Electric hand controller...
Open the catalog to page 5ELECTRICAL & SITE REQUIREMENTS Reference data for hospital installation, clinical purchasing and equipment planning. ELECTRICAL & STRUCTURAL SPECIFICATION ■ ENVIRONMENTAL CONDITIONS RANGE Mains Power AC 100-240 V, 50/60 Hz Operating Temperature 10°C to 40°C Plug Options US / EU / market-specific Operating RH 30% to 75% Drive System Electric actuator / motor drive Operating Pressure 70-106 kPa Control System Electric hand controller Storage Temperature -40°C to 55°C Main Frame A3 steel welded structure Storage RH <80%, non-condensing Surface Finish Anti-fouling powder-coated steel Storage Pressure...
Open the catalog to page 6CONFIGURATION & PROJECT SUPPORT Confirmed standard equipment and transparent specifications support procurement comparisons. STANDARD CONFIGURATION QUANTITY / DETAILS Main Examination Table 1 set Electric Hand Controller 1 pc Adjustable Leg Supports 1 pair Central Brake / Caster System Integrated Electric Sheet-Changing System Integrated OPTIONAL ACCESSORIES Project-specific accessories are available according to confirmed order requirements. No. 380 Fengxin Road, Yuhang District, Hangzhou, Zhejiang, China Tel: +86 0571 8816 1623 | Fax: +86 0571 8816 1623